Biomechanical comparison of double-loaded suture anchors using arthroscopic Mason-Allen stitches versus traditional transosseous suture technique and modified Mason-Allen stitches for rotator cuff repair.

BACKGROUND: In recent studies objective evaluations have demonstrated that arthroscopic rotator cuff repairs can have higher failure rates than open repairs. Thus, there is a need for a stronger tissue-holding stitch for arthroscopical repair. The purpose of this study was to compare the biomechanical properties of traditional open transosseous suture technique and modified Mason-Allen stitches versus double-loaded suture anchors and arthroscopic Mason-Allen stitches in rotator cuff repair. METHODS: In 20 sheep shoulders the infraspinatus tendons were dissected from their insertion and were randomized to 2 repair groups: (1) repair with transosseous suture and modified Mason-Allen stitches, (2) repair with double loaded bioabsorbable suture anchors and arthroscopic Mason-Allen stitches: Both groups were coupled with braided, nonabsorbable polyester (Ethibond) suture sized USP No. 2. All repairs were cyclically loaded from 10 to 180N with the use of a materials testing machine. The number of cycles to gap formation of 5 and 10mm at the repair site and the mode of failure were recorded. RESULTS: The number of cycles to 5-mm gap was mean 634 (SD 106) for group 1 and mean 750 (SD 107) for group 2 (P<0.026). The corresponding values to 10-mm gap were mean 1573 (SD 161) for group 1, and mean 1789 (SD 183 cycles) for group 2 (P<0.012). In group 2 the mode of failure occurred by tissue pull-out, whereas in group 1 the failure occurred by a mixture of suture breakage and pull-out. CONCLUSIONS: This time-zero study demonstrates that the combination of bioabsorbable suture anchors and arthroscopic Mason-Allen stitches provides strength superior to that of the modified Mason-Allen transosseous suture technique under isometric cyclic loading conditions. However, additional evaluation is needed to examine the effects on the sustained strength of the repair throughout the healing process.

Absorbable Implants↗

Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study.

BACKGROUND: Some patients who have a total hip replacement with a second-generation metal-on-metal articulation have persistent or early recurrence of preoperative symptoms. Characteristic histological changes in the periprosthetic tissues suggested the development of an immunological response. Therefore, in order to determine the relevance of these symptoms, we performed a study of the clinical data and periprosthetic tissues associated with endoprostheses with a metal-on metal articulation that had been retrieved at revision. METHODS: Periprosthetic tissues as well as the clinical data on the patients were obtained from the first nineteen consecutive revisions performed at the treating hospitals. At the time of the revision, fourteen patients had the metal-on-metal articulation exchanged for either an alumina-ceramic or a metal-on-polyethylene articulation. Five patients received another second-generation metal-on-metal total joint replacement. Five-micrometer sections were prepared from the tissue samples, were stained with routine and immunohistochemical methods, and were examined histologically. Histological specimens from three groups of patients, two of which were treated with non-metal-on-metal implants, served as controls. RESULTS: The majority of patients had persistence of their preoperative pain or early recurrence of the pain after the original total hip replacement, and often a pronounced hip joint effusion had developed after the original replacement. Radiographic follow-up showed the development of radiolucent lines in five hips and of osteolysis in another seven hips. At the revision surgery, both the cup and the stem were found to be well fixed in nine patients. The characteristic histological features were diffuse and perivascular infiltrates of T and B lymphocytes and plasma cells, high endothelial venules, massive fibrin exudation, accumulation of macrophages with droplike inclusions, and infiltrates of eosinophilic granulocytes and necrosis. Only a few metal particles were detected. Immunohistochemical analysis demonstrated that the cellular reaction was still active. The patients who received another second-generation metal-on-metal articulation at the time of the revision had no decrease in symptoms. In the control group of tissues obtained at revisions of endoprostheses without cobalt, chromium, or nickel articulations, there were no similar signs of immune reactions. CONCLUSIONS: These histological findings support the possibility of a lymphocyte-dominated immunological response. Although the prevalence of this reaction is low, the persistence or early reappearance of symptoms, including a marked joint effusion and the development of osteolysis, after primary implantation may suggest the possibility of such a reaction.

Aluminum Oxide↗

Ceramic and PMMA particles differentially affect osteoblast phenotype.

There is increasing evidence that wear debris particles present in periprosthetic tissues have direct effects on osteoblasts. The nature of the cell response varies with the chemistry of the particle and the number of particles. Most studies have used Ti, Ti-6Al-4V, and ultrahigh molecular weight polyethylene (UHMWPE) particles since these materials are most frequently used in implants and as a result, these particles predominate in peri-prosthetic tissues. Ceramics have also been used successfully as load-bearing surfaces in implants for years, although it is unknown how wear debris from these surfaces may contribute to aseptic bone loss. Further, particles resulting from polymethylmethacrylate (PMMA) cements used for fixation may also be involved in aseptic loosening of implants, but how these particles may affect bone formation is unknown. In the present study, we examined whether aluminum oxide (Al2O3), zirconium oxide (ZrO2), and PMMA particles exert effects on osteoblast proliferation, phenotypic expression, and local factor production, and if so, whether the effects were specific to the particle type. ZrO2 particles were produced in a custom-made axial mixer in which ZrO2 containers were filled with ZrO2 bars and 95% ethanol and then rotated continuously at room temperature. PMMA particles were prepared in a ZrO2 roller mill. Al2O3 was produced and provided by Aesculap AG. Particles were endotoxin-free with equivalent circle diameters <3 microm; Al2O3 particles were significantly smaller than ZrO2 or PMMA particles. Particle suspensions were added to confluent cultures of MG63 osteoblast-like cells after diluting them 1:100, 1:10, and 1:1 with culture medium. Cells were incubated with the particles for 24 h. Transmission electron microscopy showed that MG63 cells phagocytosed Al2O3 particles and exhibited ultrastructural changes consistent with cytotoxicity. This was supported by biochemical changes as well. Proliferation, alkaline phosphatase activity, and TGF-beta1 levels were decreased. ZrO2 and PMMA particles increased proliferation and alkaline phosphatase specific activity. The effect of ZrO2 on alkaline phosphatase was targeted to matrix vesicles, the effect of PMMA was greater on the cells. All particles increased prostaglandin E2 production. These results show that Al2O3, ZrO2, and PMMA particles elicit direct effects on osteoblasts and that cell response depends on the particle type. None of the particles tested had the same effect as noted previously for UHMWPE: increased proliferation and decreased alkaline phosphatase. These results may indicate that the response of peri-prosthetic tissues to wear particles may be modulated by the relative contributions of the various particle types present.

Alkaline Phosphatase↗

New aspects in the histological examination of polyethylene wear particles in failed total joint replacements.

The most important long-term complication in total joint replacements is aseptic osteolysis. Wear particles such as polyethylene (PE) debris are considered to be one of the causes that play a central role. Several studies indicated that PE can be visualised in paraffin-embedded tissue sections not only by polarised light, but also after oil red staining. To determine whether oil red staining enables sensitive detection of PE, we examined staining of mechanically-produced PE particles by oil red. Furthermore, we studied oil red staining of paraffin-embedded tissue specimens of patients with failed uncemented and cemented total knee and hip prostheses. We applied double labelling of sections by immunohistochemistry using the macrophage marker anti-CD68 and oil red staining. We found that oil red stains both isolated PE particles and PE particles in paraffin-embedded tissue sections. Polymethylmethacrylate particles in failed cemented arthroplasties did not stain in paraffin sections. Double labelling showed strong colocalisation of CD68 and PE. We suggest that oil red staining is a sensitive method to detect PE particles. Oil red staining is particularly helpful in these cases which show a characteristic histological feature of aseptic prosthesis loosening without particles being detectable with routine microscopy and polarised light. We also established that immunohistochemical methods can be applied together with the oil red staining method.