Self-calibrating 3D-ultrasound-based bone registration for minimally invasive orthopedic surgery.

Intraoperative freehand three-dimensional (3-D) ultrasound (3D-US) has been proposed as a noninvasive method for registering bones to a preoperative computed tomography image or computer-generated bone model during computer-aided orthopedic surgery (CAOS). In this technique, an US probe is tracked by a 3-D position sensor and acts as a percutaneous device for localizing the bone surface. However, variations in the acoustic properties of soft tissue, such as the average speed of sound, can introduce significant errors in the bone depth estimated from US images, which limits registration accuracy. We describe a new self-calibrating approach to US-based bone registration that addresses this problem, and demonstrate its application within a standard registration scheme. Using realistic US image data acquired from 6 femurs and 3 pelves of intact human cadavers, and accurate Gold Standard registration transformations calculated using bone-implanted fiducial markers, we show that self-calibrating registration is significantly more accurate than a standard method, yielding an average root mean squared target registration error of 1.6 mm. We conclude that self-calibrating registration results in significant improvements in registration accuracy for CAOS applications over conventional approaches where calibration parameters of the 3D-US system remain fixed to values determined using a preoperative phantom-based calibration.

Algorithms↗

Multispectral MR to X-ray registration of vertebral bodies by generating CT-like data.

A new method for MR to X-ray registration is presented. Based on training data, consisting of registered multispectral MR and CT data, a function is defined that maps multispectral MR data to CT-like data. For new subjects for which multispectral MR data have been acquired, the mapping function is used to generate a corresponding CT-like dataset. The CT-like image is subsequently used for registration to X-ray data, using gradient-based registration. Preliminary experiments indicate that MR to X-ray registration using this method is more accurate and has a larger capture range than gradient-based registration applied directly to MR data.

Algorithms↗

Cadaver validation of intensity-based ultrasound to CT registration.

A method is presented for the registration of tracked B-mode ultrasound images to a CT volume of a femur or pelvis. This registration can allow tracked surgical instruments to be aligned with the CT image or an associated preoperative plan. Our method requires no manual segmentation of either the ultrasound images or the CT volume. The CT and US images are processed to produce images where the image intensity represents the probability of the presence of a bone edge. These images are then registered together using normalised cross-correlation as a similarity measure. The parameter which represents the speed of sound through tissue has also been included in the registration optimisation process. Experiments have been carried out on six cadaveric femurs and three cadaveric pelves. Registration results were compared with a "gold standard" registration acquired using bone implanted fiducial markers. Results show the registration method to be accurate, on average, to 1.7 mm root-mean-square target registration error.

Algorithms↗

Standardized evaluation methodology for 2-D-3-D registration.

In the past few years, a number of two-dimensional (2-D) to three-dimensional (3-D) (2-D-3-D) registration algorithms have been introduced. However, these methods have been developed and evaluated for specific applications, and have not been directly compared. Understanding and evaluating their performance is therefore an open and important issue. To address this challenge we introduce a standardized evaluation methodology, which can be used for all types of 2-D-3-D registration methods and for different applications and anatomies. Our evaluation methodology uses the calibrated geometry of a 3-D rotational X-ray (3DRX) imaging system (Philips Medical Systems, Best, The Netherlands) in combination with image-based 3-D-3-D registration for attaining a highly accurate gold standard for 2-D X-ray to 3-D MR/CT/3DRX registration. Furthermore, we propose standardized starting positions and failure criteria to allow future researchers to directly compare their methods. As an illustration, the proposed methodology has been used to evaluate the performance of two 2-D-3-D registration techniques, viz. a gradient-based and an intensity-based method, for images of the spine. The data and gold standard transformations are available on the internet (http://www.isi.uu.nl/Research/Databases/).

Algorithms↗

Alignment of sparse freehand 3-D ultrasound with preoperative images of the liver using models of respiratory motion and deformation.

We present a method for alignment of an interventional plan to optically tracked two-dimensional intraoperative ultrasound (US) images of the liver. Our clinical motivation is to enable the accurate transfer of information from three-dimensional preoperative imaging modalities [magnetic resonance (MR) or computed tomography (CT)] to intraoperative US to aid needle placement for thermal ablation of liver metastases. An initial rigid registration to intraoperative coordinates is obtained using a set of US images acquired at maximum exhalation. A preprocessing step is applied to both the preoperative images and the US images to produce evidence of corresponding structures. This yields two sets of images representing classification of regions as vessels. The registration then proceeds using these images. The preoperative images and plan are then warped to correspond to a single US slice acquired at an unknown point in the breathing cycle where the liver is likely to have moved and deformed relative to the preoperative image. Alignment is constrained using a patient-specific model of breathing motion and deformation. Target registration error is estimated by carrying out simulation experiments using resliced MR volumes to simulate real US and comparing the registration results to a "bronze-standard" registration performed on the full MR volume. Finally, the system is tested using real US and verified using visual inspection.

Algorithms↗

Intensity-based 2-D-3-D registration of cerebral angiograms.

We propose a new method for aligning three-dimensional (3-D) magnetic resonance angiography (MRA) with 2-D X-ray digital subtraction angiograms (DSA). Our method is developed from our algorithm to register computed tomography volumes to X-ray images based on intensity matching of digitally reconstructed radiographs (DRRs). To make the DSA and DRR more similar, we transform the MRA images to images of the vasculature and set to zero the contralateral side of the MRA to that imaged with DSA. We initialize the search for a match on a user defined circular region of interest. We have tested six similarity measures using both unsegmented MRA and three segmentation variants of the MRA. Registrations were carried out on images of a physical neuro-vascular phantom and images obtained during four neuro-vascular interventions. The most accurate and robust registrations were obtained using the pattern intensity, gradient difference, and gradient correlation similarity measures, when used in conjunction with the most sophisticated MRA segmentations. Using these measures, 95% of the phantom start positions and 82% of the clinical start positions were successfully registered. The lowest root mean square reprojection errors were 1.3 mm (standard deviation 0.6) for the phantom and 1.5 mm (standard deviation 0.9) for the clinical data sets. Finally, we present a novel method for the comparison of similarity measure performance using a technique borrowed from receiver operator characteristic analysis.