PubMed Health⌕ Search

Biomedical subjects

Graham Sommer

Publications and source records attributed to Graham Sommer.

8 recordsLinked to original sources

Measurement of renal extraction fraction with contrast-enhanced CT.

Study was approved by the institutional review board, and informed patient consent was waived. A method for minimization of sources of variability in measuring single-kidney extraction fraction (EF) was determined retrospectively with contrast material-enhanced computed tomography (CT). Ten adults underwent CT of the kidneys; precontrast scans were obtained, followed by postcontrast scanning 2 minutes after contrast material injection. Single-kidney EF was then calculated for each patient with the formula EF = (CT(A) - CT(V))/(CT(A) - CT(PRE)), where CT(A) and CT(V) are the postcontrast CT values (in Hounsfield units) of the systemic blood and renal venous blood, respectively, and CT(PRE) is the precontrast CT value of the blood. Both conventional two-dimensional and volumetric three-dimensional regions of interest were used for determining mean CT values of the blood. By using the volumetric regions of interest, left and right renal EF values averaged 17.3% and 18.0%, respectively, for two observers, compared with the accepted value of 15%-20%. This latter technique also minimized right-left kidney and interobserver variability in the measurement of EF.

Adult↗

Rapid measurement of renal artery blood flow with ungated spiral phase-contrast MRI.

PURPOSE: To verify the potential of ungated spiral phase-contrast (USPC), which has been shown to provide accurate and reproducible time-averaged measurements of pulsatile flow, for rapid measurement of renal artery blood flow (RABF) in vivo. MATERIALS AND METHODS: The RABF rates of 11 normal human subjects and one patient with renal failure were measured with USPC within six seconds. RESULTS: Rapid USPC scans produced reproducible RABF measurements (SD < or = 9%) that agreed with the normal RABF rates known from the literature. The RABF rates of the patient with renal failure were substantially less (<50-65%) than the normal RABF rates. CONCLUSION: The results demonstrate that it is now possible to obtain rapid and consistent RABF measurements within six seconds with USPC.

Adult↗

MRI-guided interstitial ultrasound thermal therapy of the prostate: a feasibility study in the canine model.

The feasibility of MRI-guided interstitial ultrasound thermal therapy of the prostate was evaluated in an in vivo canine prostate model. MRI compatible, multielement interstitial ultrasound applicators were developed using 1.5 mm diameter cylindrical piezoceramic transducers (7 to 8 MHz) sectored to provide 180 degrees of angular directional heating. Two in vivo experiments were performed in canine prostate. The first using two interstitial ultrasound applicators, the second using three ultrasound applicators in conjunction with rectal and urethral cooling. In both experiments, the applicators were inserted transperineally into the prostate with the energy directed ventrally, away from the rectum. Electrical power levels of 5-17 W per element (approximately 1.6-5.4 W acoustic output power) were applied for heating periods of 18 and 48 min. Phase-sensitive gradient-echo MR imaging was used to monitor the thermal treatment in real-time on a 0.5 T interventional MRI system. Contrast-enhanced T1-weighted images and vital-stained serial tissue sections were obtained to assess thermal damage and correlate to real-time thermal contour plots and calculated thermal doses. Results from these studies indicated a large volume of ablated (nonstained) tissue within the prostate, extending 1.2 to 2.0 cm from the applicators to the periphery of the gland, with the dorsal margin of coagulation well-defined by the applicator placement and directionality. The shape of the lesions correlated well to the hypointense regions visible in the contrast-enhanced T1-weighted images, and were also in good agreement with the contours of the 52 degrees C threshold temperature and t43 > 240 min. This study demonstrates the feasibility of using directional interstitial ultrasound in conjunction with MRI thermal imaging to monitor and possibly control thermal coagulation within a targeted tissue volume while potentially protecting surrounding tissue, such as rectum, from thermal damage.

Animals↗

Curvilinear transurethral ultrasound applicator for selective prostate thermal therapy.

Thermal therapy offers a minimally invasive option for treating benign prostatic hyperplasia (BPH) and localized prostate cancer. In this study we investigated a transurethral ultrasound applicator design utilizing curvilinear, or slightly focused, transducers to heat prostatic tissue rapidly and controllably. The applicator was constructed with two independently powered transducer segments operating at 6.5 MHz and measuring 3.5 mm x 10 mm with a 15 mm radius of curvature across the short axis. The curvilinear applicator was characterized by acoustic efficiency measurements, acoustic beam plots, biothermal simulations of human prostate, ex vivo heating trials in bovine liver, and in vivo heating trials in canine prostate (n=3). Each transducer segment was found to emit a narrow acoustic beam (max width <3 mm), which extended the length of the transducer, with deeper penetration than previously developed planar or sectored tubular transurethral ultrasound applicators. Acoustic and biothermal simulations of human prostate demonstrated three treatment schemes for the curvilinear applicator: single shot (10 W, 60 s) schemes to generate narrow ablation zones (13 x 4 mm, 52 degrees C at the lesion boundary), incremental rotation (10 W, 10 degrees/45 s) to generate larger sector-shaped ablation zones (16 mm x 180 degrees sector), and rotation with variable sonication times (10 W, 10 degrees/15-90 s) to conform the ablation zone to a predefined boundary (9-17 mm x 180 degrees sector, 13 min total treatment time). During in vivo canine prostate experiments, guided by MR temperature imaging, single shot sonications (6 W/transducer, 2-3 min) with the curvilinear applicator ablated 20 degree sections of tissue to the prostate boundary (9-15 mm). Multiple adjacent sonications ("sweeping") ablated large sections of the prostate (180 degrees) by using the MR temperature imaging to adjust the power (4-6.4 W/transducer) and sonication time (30-180 s) at each 10 degrees rotation such that the periphery of the prostate reached 52 degrees C before the next rotation. The conclusion of this study was that the curvilinear applicator produces a narrow and penetrating ultrasound beam that, when combined with image guidance, can provide a precise technique for ablating target regions with a contoured outer boundary, such as the prostate capsule, by rotating in small steps while dynamically adjusting the net applied electrical power and sonication time at each position.

Acoustics↗

Highly directional transurethral ultrasound applicators with rotational control for MRI-guided prostatic thermal therapy.

Transurethral ultrasound applicators with highly directional energy deposition and rotational control were investigated for precise treatment of benign prostatic hyperplasia (BPH) and adenocarcinoma of the prostate (CaP). Two types of catheter-based applicators were fabricated, using either 90 degrees sectored tubular (3.5 mm OD x 10 mm) or planar transducers (3.5 mm x 10 mm). They were constructed to be MRI compatible, minimally invasive and allow for manual rotation of the transducer array within a 10 mm cooling balloon. In vivo evaluations of the applicators were performed in canine prostates (n = 3) using MRI guidance (0.5 T interventional magnet). MR temperature imaging (MRTI) utilizing the proton resonance frequency shift method was used to acquire multiple-slice temperature overlays in real time for monitoring and guiding the thermal treatments. Post-treatment T1-weighted contrast-enhanced imaging and triphenyl tetrazolium chloride stained tissue sections were used to define regions of tissue coagulation. Single sonications with the 90 degrees tubular applicator (9-15 W, 12 min, 8 MHz) produced coagulated zones covering an 80 degrees wedge of the prostate extending from 1-2 mm outside the urethra to the outer boundary of the gland (16 mm radial coagulation). Single sonications with the planar applicator (15-20 W, 10 min, approximately 8 MHz) generated thermal lesions of approximately 30 degrees extending to the prostate boundary. Multiple sequential sonications (sweeping) of a planar applicator (12 W with eight rotations of 30 degrees each) demonstrated controllable coagulation of a 270 degrees contiguous section of the prostate extending to the capsule boundary. The feasibility of using highly directional transurethral ultrasound applicators with rotational capabilities to selectively coagulate regions of the prostate while monitoring and controlling the treatments with MRTI was demonstrated in this study.

Acoustics↗

Referenceless PRF shift thermometry.

The proton resonance frequency (PRF) shift provides a means of measuring temperature changes during minimally invasive thermotherapy. However, conventional PRF thermometry relies on the subtraction of baseline images, which makes it sensitive to tissue motion and frequency drift during the course of treatment. In this study, a new method is presented that eliminates these problems by estimating the background phase from each acquired image phase. In this referenceless method, a polynomial is fit to the background phase outside the heated region in a weighted least-squares fit. Extrapolation of the polynomial to the heated region serves as the background phase estimate, which is then subtracted from the actual phase. The referenceless method is demonstrated on a phantom during laser heating, 0 degrees temperature rise images of in vivo human liver, interstitial laser ablation of porcine liver, and transurethral ultrasound ablation of canine prostate. A good correlation between temperature maps reconstructed with the referenceless and subtraction methods was found.

Animals↗

Measurement of renal extraction fraction using contrast-enhanced computed tomography.

Renal extraction fraction (EF) is the percentage of plasma entering the glomerulus which is filtered. Contrast agents which are freely filtered and neither secreted nor reabsorbed, may be used as markers for renal filtration, allowing EF to be calculated from computed tomography (CT) measurements of systemic vessels and renal veins. CT scans of 10 adult patients having no known renal disease were studied in this manner, giving EF values averaging 12.6% and 12.3% for the right and left kidneys, respectively, compared to the accepted value of 15%-20%. EF measurement using CT may provide noninvasive evaluation of renal function, complementing CT-derived morphologic information.

Adult↗

Evaluation of renal growth by magnetic resonance imaging and computerized tomography volumes.

PURPOSE: Magnetic resonance imaging (MRI) and computerized tomography (CT) are commonly used to image complex medical conditions but limited data have been reported concerning normal renal volumetric measurement with these imaging techniques. We examined whether normative renal growth curves could be constructed from data derived from these imaging modalities, and from these curves assessed normal and abnormal renal development. MATERIALS AND METHODS: Patients who had undergone prior renal MRI or CT were identified. Total renal volume and renal cortical fraction (CF, cortical/total volume) were calculated, and growth curves were derived. To examine the curve utility for abnormal growth assessment, renal ultrasonography of children with reflux nephropathy was examined, and MRI and radionuclide scans were compared. RESULTS: A total of 60 patients 2 months to 39 years old who underwent MRI were included in the growth curve. The CF of the 120 kidneys was 75.8 +/- 4.3% and independent of sex and age. In 19 patients with vesicoureteral reflux 13 kidneys had cortical scarring, and the CF was decreased (p <0.001, 63.65 +/- 5.72%), indicating disproportionate cortical loss. No difference between CF for normal and vesicoureteral reflux unscarred kidneys was found. Differential renal function on radionuclide study correlated highly with MRI renal volume (r = 0.91). CT was performed in 70 children 1 to 15 years old (mean age 7.9) volume correlated with age and renal length, and the left kidney was larger than right kidney on MRI and CT. CONCLUSIONS: Normative renal growth curves can be constructed from CT and MRI derived renal volumes. Cortical fraction is consistent, and sex and age independent. In reflux nephropathy the CF is reduced and renal differential function on nuclear scan correlates with MRI derived differential volume. This concept may be useful for predicting abnormal renal growth and differential function.

Adolescent↗