PubMed Health⌕ Search

Biomedical subjects

Greg Collins

Publications and source records attributed to Greg Collins.

7 recordsLinked to original sources

Quantum-dot/aptamer-based ultrasensitive multi-analyte electrochemical biosensor.

The coupling of aptamers with the coding and amplification features of inorganic nanocrystals is shown for the first time to offer a highly sensitive and selective simultaneous bioelectronic detection of several protein targets. This is accomplished in a single-step displacement assay in connection to a self-assembled monolayer of several thiolated aptamers conjugated to proteins carrying different inorganic nanocrystals. Electrochemical stripping detection of the nondisplaced nanocrystal tracers results in a remarkably low (attomole) detection limit, that is, significantly lower than those of existing aptamer biosensors. The new device offers great promise for measuring a large panel of disease markers present at ultralow levels during early stages of the disease progress.

Aptamers, Peptide↗

Multiple enzyme layers on carbon nanotubes for electrochemical detection down to 80 DNA copies.

Signal amplification using enzyme multilayers on carbon nanotube (CNT) templates is shown to yield a remarkably sensitive electrochemical detection of proteins and nucleic acids. The electrostatic layer-by-layer (LBL) self-assembly onto CNT carriers maximizes the ratio of enzyme tags per binding event to offer the greatest amplification factor reported to date. Absorption spectroscopy, TEM, and electrochemical characterization confirm the formation of LBL enzyme nanostructures on individual CNT carriers. The enzymatic activity is found to increase with the number of enzyme layers. The new protocol is illustrated for monitoring sandwich hybridization and antibody-antigen interactions in connection with alkaline phosphatase tracers. Factors affecting the enzyme loading and the analytical performance have been optimized. Such amplified bioelectronic assays allow detection of DNA and proteins down to 80 copies (5.4 aM) and 2000 protein molecules (67 aM), respectively. Given the enormous amplification afforded by the new CNT-LBL biolabel, such route offers great promise for ultrasensitive detection of infectious agents and disease markers.

DNA↗

Effects of a nicotine conjugate vaccine on the acquisition and maintenance of nicotine self-administration in rats.

RATIONALE: Immunization of rats against nicotine using a nicotine conjugate vaccine reduces the distribution of nicotine to brain in rats and attenuates some of nicotine's physiological and behavioral effects. It is not known whether such a vaccine can attenuate nicotine's reinforcing effects. OBJECTIVE: The present experiment was conducted to determine whether a nicotine conjugate vaccine could interfere with the acquisition and maintenance of nicotine self-administration (NSA) in rats given 23 h day(-1) access to nicotine. METHODS: To examine acquisition of NSA, rats were vaccinated with nicotine or control immunogen prior to being given access to a 0.01 mg kg(-1) infusion(-1) nicotine under a fixed-ratio(FR) 1 schedule for week 1, FR 2 for week 2, and FR 3 for week 3. Acquisition of cocaine self-administration (CSA) was similarly examined to determine the specificity of vaccination effects. To examine maintenance of NSA, rats were initially trained to self-administer nicotine under an FR 3 schedule, and then vaccinated with nicotine or control immunogen while NSA continued to be monitored. RESULTS: NSA was significantly lower in vaccinated rats compared to controls during the acquisition protocol, with a 38% decrease in the number of infusions during the last week of training. The percentage of rats meeting acquisition criteria in the vaccinated group was lower (36%) than that in the control group (70%), but this difference was not statistically significant. Vaccination did not affect acquisition of CSA, demonstrating its specificity for nicotine. Maintenance of NSA was significantly reduced in vaccinated rats as compared to controls after the final vaccine injection, with a mean reduction of 57%. There was no evidence in either protocol that vaccinated rats attempted to compensate for altered nicotine distribution by increasing nicotine intake. CONCLUSION: These data suggest that vaccination against nicotine can reduce the reinforcing effects of nicotine in rats and may have therapeutic potential for the treatment of tobacco dependence.

Animals↗

Effects of nicotine infusion on the metabolism of the tobacco carcinogen 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK) in rats.

The tobacco-specific nitrosamine, 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK) is a lung carcinogen in the rat and believed to be a causative agent for lung cancer in smokers. To exert its carcinogenic potential NNK is metabolically activated by cytochrome P450-catalyzed alpha-hydroxylation. Nicotine and NNK share metabolic pathways. The purpose of this study was to determine whether nicotine alters the fraction of NNK undergoing activation to carcinogenic metabolites. Rats received acute (36 h) or chronic (2 week) s.c. infusions of nicotine at rates producing serum nicotine concentrations 2-3 times the usual venous nicotine concentrations measured in smokers. A single dose of [5-3H]-NNK was administered i.p. 24 h prior to the end of each infusion. Urine was collected for 24 h thereafter and NNK metabolites quantified by radioflow HPLC. Neither acute nor chronic nicotine infusion had any effect on the extent of NNK metabolism by alpha-hydroxylation. These data suggest that nicotine infusion, at rates simulating the higher doses of nicotine replacement therapy now being studied for smoking cessation, neither induces nor inhibits NNK metabolism appreciably and therefore should not alter the formation of carcinogenic NNK metabolites.

Animals↗

Effects of continuous nicotine infusion on nicotine self-administration in rats: relationship between continuously infused and self-administered nicotine doses and serum concentrations.

RATIONALE: The efficacy of nicotine replacement therapy (NRT) for smoking cessation is limited. One reason for this limited efficacy may be that typical serum nicotine concentrations provided by NRT do not match the peak arterial nicotine concentrations achieved from smoking. OBJECTIVE: The purpose of the present study was to determine whether continuous nicotine infusion at a rate producing serum nicotine concentrations that match the estimated peak arterial nicotine concentrations associated with nicotine self-administration (NSA) in rats produces greater suppression of NSA than lower infusion rates. METHODS: The effects of continuous nicotine infusion were studied by intravenously administering nicotine at various rates (1.0, 3.0, and 8.0 mg/kg per day) to rats concurrently self-administering nicotine (0.03 mg/kg per infusion) during 23-h sessions or cocaine (0.17 mg/kg per infusion) during 2-h sessions. RESULTS: Continuous nicotine infusion suppressed NSA in a rate-related fashion. NSA was suppressed by 17, 50, and 73% at infusion rates of 1.0, 3.0 and 8.0 mg/kg per day, respectively. The 8.0-mg/kg per day infusion rate, which provided venous serum nicotine concentrations equaling the peak arterial concentrations associated with NSA, suppressed NSA to a greater extent than lower infusion rates. The 8.0-mg/kg per day nicotine infusion rate had no effect on cocaine-maintained responding, demonstrating that its effects were specific for suppression of NSA. This infusion rate provided a mean percentage replacement of nicotine from NSA of more than 700%. Reacquisition of NSA after suppression by the two highest infusion rates was delayed compared with reacquisition after saline extinction. CONCLUSIONS: Continuous nicotine infusion produced an infusion rate-related suppression of NSA that was greatest when the infusion provided nicotine doses and venous serum concentrations substantially higher than those typically associated with NRT in humans.

Animals↗

Single-channel microchip for fast screening and detailed identification of nitroaromatic explosives or organophosphate nerve agents.

A single-channel chip-based analytical microsystem that allows rapid flow injection measurements of the total content of organic explosive or nerve agent compounds, as well as detailed micellar chromatographic identification of the individual ones, is described. The protocol involves repetitive rapid flow injection (screening) assays--to provide a timely warning and alarm--and switching to the separation (fingerprint identification) mode only when harmful compounds are detected. While micellar electrokinetic chromatography, in the presence of sodium dodecyl sulfate (SDS), is used for separating the neutral nitroaromatic explosive and nerve agent compounds, an operation without SDS leads to high-speed measurements of the "total" explosives or nerve agent content. Switching between the "flow injection" and "separation" modes is accomplished by rapidly exchanging the SDS-free and SDS-containing buffers in the separation channel. Amperometric detection was used for monitoring the separation. Key factors influencing the sample throughput, resolution, and sensitivity have been assessed and optimized. Assays rates of about 360 and 30/h can thus be realized for the "total" screening and "individual" measurements, respectively. Ultimately, such development will lead to the creation of a field-deployable microanalyzer and will enable transporting the forensic laboratory to the sample source.

Chemical Warfare Agents↗

A chip-based capillary electrophoresis-contactless conductivity microsystem for fast measurements of low-explosive ionic components.

A miniaturized analytical system for separating and detecting inorganic explosive residues, based on the coupling of a micromachined capillary electrophoresis (CE) chip with a contactless conductivity detector is described. The low electroosmotic flow (EOF) of the poly(methylmethacrylate) (PMMA) chip material facilitates the rapid switching between analyses of cations and anions using the same microchannel and run buffer (and without an EOF modifier), and hence offers rapid (< 1 min) measurement of seven explosive-related cations and anions. Experimental parameters relevant to the separation and detection processes have been optimized. Addition of a 18-crown-6 ether modifier has been used for separating the peaks of co-migrating potassium and ammonium ions. The ionic-explosive microchip system combines the distinct advantages of contactless conductivity detection with the attractive features of plastic CE microchips. The new microsystem offers great promise for monitoring explosive-related ions at the sample source, with significant advantages of speed/warning, efficiency, cost, or sample size.

Electrophoresis, Capillary↗