PubMed Health⌕ Search

Biomedical subjects

Greg W Dicinoski

Publications and source records attributed to Greg W Dicinoski.

8 recordsLinked to original sources

Simultaneous determination of monofluoroacetate, difluoroacetate and trifluoroacetate in environmental samples by ion chromatography.

A method is reported for the sensitive, simultaneous determination of mono- (MFA), di- (DFA), and trifluoroacetates (TFA) by ion chromatography (IC). These species were separated using a Dionex AS17 anion-exchange column employed with a potassium hydroxide gradient (via a Dionex EG40 eluent generator) and suppressed conductivity detection. The fluoroacetates were successfully separated from a range of inorganic and organic species likely to be present in environmental samples, in a total analysis time of 35 min (including re-equilibration of the column). Detection limits for mono-, di- and trifluoroacetate were 21, 38 and 36 microg/l, respectively, determined using a signal-to-noise ratio of 3, and were obtained using a sample injection volume of 50 microl. Precision was less than 0.83% relative standard deviation (RSD) for replicate injections performed over a period of 30 days. The method was applied to the determination of monofluoroacetate in river water samples and also in carrot baits.

Chromatography, Liquid↗

Mechanistic studies on the separation of cations in zwitterionic ion chromatography.

Electrostatic ion chromatography, also known as zwitterionic ion chromatography, has been predominantly used for the analysis of anions. Consequently, separation mechanisms proposed for this technique have been based on anion retention data obtained using a sulfobetaine-type surfactant-coated column. A comprehensive cation retention data set has been obtained on a C18 column coated with the zwitterionic surfactant N-tetradecylphosphocholine (which has the negatively and positively charged functional groups reversed in comparison to the sulfobetaine surfactants), with mobile phases being varied systematically in the concentration and species of both the mobile-phase anion and cation. A retention mechanism based on both an ion exclusion effect and a direct (chaotropic) interaction with the inner negative charge on the zwitterion is proposed for the retention of cations. Despite the relatively low chaotropic nature of cations compared with anions, the retention data shows that cations are retained in this system predominantly due to a chaotropic interaction with the inner charge, analogous to anions in a system where the C18 column is coated with a sulfobetaine-type surfactant. The retention of an analyte cation, and the effect of the mobile-phase anion and cation, can be predicted by the relative positions of these species on the Hofmeister (chaotropic) series.

Anions↗

Selectivity behaviour of a bonded phosphonate--carboxylate polymeric ion exchanger for metal cations with varying eluent compositions.

The chromatographic behaviour of a commercially available ion-exchange stationary phase (the Dionex IonPac CS12A column) is described for a wide range of transition and heavy metal ions with nitric acid eluents containing chloride and nitrate potassium salts. The separation selectivity was found to arise from simultaneous ion-exchange interactions and chelation with the attached carboxylic and phosphonic acid groups. These interactions were investigated by altering the ionic strength and pH of the eluent and also the column temperature. Strong affinity of the stationary phase towards heavy metal ions, in particular bismuth and the uranyl ion was observed at low pH under chelating ion-exchange conditions, with high efficiency separations of other ions including cadmium and lead being possible with short analysis times (approximately 5-15 min). Examples are given of separations obtained using 4-(2-pyridylazo)resorcinol or Arsenazo III as the post-column chromogenic reagents, demonstrating the potential versatility and utility of this stationary phase for heavy metal ion analysis.

Carboxylic Acids↗

Separation of thiosulfate and the polythionates in gold thiosulfate leach solutions by capillary electrophoresis.

A technique for the separation of thiosulfate (S(2)O(3) (2-)), polythionates (S(x)O(6) (2-), x = 3 to 5) and the gold(I) thiosulfate complex (Au(S(2)O(3))(2) (3-)) using capillary electrophoresis with simultaneous UV detection at 195 and 214 nm is presented. The five species were separated in under 3 min with a total analysis time of 8 min, using an electrolyte containing 25 mM 2,2-bis(hydroxymethyl)-2,2',2"-nitrilotriethanol (bis-tris) adjusted to pH 6.0 with sulfuric acid and an applied voltage of -30 kV. While the gold(I) thiosulfate complex could be separated from the other analytes of interest under these conditions, the quantification of this complex was not possible due to inconsistent peak areas and peak splitting effects induced by the sulfur-oxygen species in the leach matrix. Detection limits calculated for 3s pressure injection at 50 mbar ranged between 0.5-2 microM. The method was linear over the ranges 40-8000, 10-2000, 10-2000, and 5-2000 microM for thiosulfate, trithionate, tetrathionate, and pentathionate, respectively. The technique was applied successfully to leach liquors containing 0.5 M ammonium thiosulfate, 2 M ammonia, 0.05 M copper sulfate and 20% w/v gold ore, diluted 1:100 prior to analysis.

Electrolytes↗

Simulation and optimization of retention in ion chromatography using virtual column 2 software.

A new software package, Virtual Column 2, is described for the simulation and optimization of the separation of inorganic anions by ion chromatography (IC). The software uses a limited amount of experimental retention data acquired according to a correct experimental design to predict retention times for analytes over a designated search area of eluent compositions. The experimental retention data are used to solve a new retention model, called the linear solvent strength model, empirical approach (LSSM-EA), which then enables prediction of retention times for all eluent compositions in the search area. The theoretical development of LSSM-EA and the processes used for solving the equations are discussed. Virtual Column 2 can be used for eluents containing one or two competing ions, and the software contains retention databases for up to 33 analytes on the Dionex AS9A-HC, AS4A-SC, and AS14A analytical columns with carbonate-bicarbonate eluents and the Dionex AS10, AS15, and AS16 analytical columns with hydroxide eluents (results for the AS10 and AS15 columns are not discussed in the present study). Virtual Column 2 has been evaluated extensively and is shown to give predicted retention times that in most cases agree with experimentally determined data to within 5%. The software has uses in practical IC method development, education and training in IC, and refinement of existing IC methodology. A free version of this program is available by download at www.virtualcolumn.com.

Journal Article↗

Determination of vanadium as 4-(2-pyridylazo)resorcinol-hydrogen peroxide ternary complexes by ion-interaction reversed-phase liquid chromatography.

The separation and determination of the vanadium(V) ternary complex formed with 4-(2-pyridylazo)resorcinol (PAR) and hydrogen peroxide using ion-interaction reversed-phase high-performance liquid chromatography on a C18 column has been investigated. The optimal mobile phase was a methanol-water solution (32:68, v/v) containing 3 mM tetrabutylammonium bromide, 5 mM acetic acid and 5 mM citrate buffer at pH 7, with absorbance detection at 540 nm. The stoichiometry of the ternary complex of vanadium at pH 6 in 10 mM acetate buffer using the mole ratio and Job's method by HPLC indicated that the mole ratio of V(V):PAR:H2O2 was 1:1:1. The optimal conditions for precolumn formation of the ternary complex were 10 mM acetate, 7 mM H2O2, 0.3 mM PAR, and pH 6. The method gave relative standard deviations of retention time, peak area and peak height for the ternary complex of 0.187, 0.45 and 0.57%, respectively. The detection limit (at a signal-to-noise ratio of 3) for V(V) was 0.09 ng/ml in the digested sample using a 100-microl injection loop (or 0.09 microg/g in the solid fertiliser sample). The method was applied to the analysis of fertilisers (phosphate rocks and nitrogen, phosphorus and potassium fertiliser). The results for vanadium obtained by the HPLC method agreed well with those from magnetic sector inductively coupled plasma MS analysis.

Chromatography, High Pressure Liquid↗

New conductivity detection response equation for anions eluted with fully and partially ionised eluents in non-suppressed ion chromatography.

A response equation for conductivity detection in ion chromatography has been derived. This equation is applicable to non-suppressed ion chromatography using both fully ionised and partially ionised eluents. A prime assumption of this equation is that when partially ionised eluents are used (such as benzoic acid), both the ionised and neutral components of the eluent species contribute to the detector response of anionic analytes. Experimental evidence is provided to support this assumption in that pH changes accompanying the elution of an analyte have been measured. These pH changes are proportional to the concentration of analyte injected onto the column, in accordance with predictions from the response equation. Furthermore, it is shown that protonated eluents (such as benzoic acid) give more sensitive detection than equivalent ionised eluents (such as potassium benzoate) and the signal enhancement achieved using a protonated eluent species is in accordance with theory.

Anions↗

Separation of polythionates and the gold thiosulfate complex in gold thiosulfate leach solutions by ion-interaction chromatography.

A method for the separation of the polythionates (SxO6(2-), x = 3-5) in gold thiosulfate leach solutions using ion-interaction chromatography with conductivity and ultraviolet (UV) detection is described. Polythionates were eluted within 18 min using an eluent comprising an acetonitrile step gradient at 0.0 min from 15% v/v to 28% v/v, 3 mM TBAOH, and 2.5 mM sodium carbonate, operated using a Dionex NS1-5 micron column with guard. The developed method was capable of separating the gold thiosulfate complex ion in standard solutions, but quantification of this species in realistic leach solutions proved impractical due to a self-elution effect that caused the gold peak to be eluted as a broad band. Detection limits for polythionates using a 10 microL injection volume ranged between 1-6 mg L(-1) (5-23 microM) for conductivity and 0.8-13 mg L(-1) (4-68 microM) for UV detection, based on a signal-to-noise ratio of 2. Calibration was linear over the ranges 5-2000, 10-2000 and 25-2500 mg L(-1) for trithionate, tetrathionate and pentathionate, respectively. The technique was applied successfully to leach liquors containing 0.5 M ammonium thiosulfate, 2 M ammonia, 0.05 M copper sulfate and 20 % m/v gold ore.

Journal Article↗