PubMed Health⌕ Search

Biomedical subjects

Gregg W Stone

Publications and source records attributed to Gregg W Stone.

203 records · Page 12Linked to original sources

Clinical outcome following percutaneous coronary interventions in patients with chronic renal failure.

The clinical outcome of patients with chronic renal failure (CRF) who undergo percutaneous coronary intervention (PCI) has not been systematically evaluated in a large cohort of patients. We retrospectively analyzed the in-hospital and 1-year clinical outcomes of 10,076 consecutive patients who underwent PCI between January 1994 and December 1997. A total of 95 patients (0.9%) had end-stage renal disease (ESRD) on dialysis, 786 patients (7.8%) had CRF, and 9,125 patients (90.6%) had normal renal function. Despite an angiographic success rate of 97% in all three groups, in-hospital mortality was significantly higher among patients with renal disease, whether they were on dialysis or not, when compared to patients without renal dysfunction (6.8% vs. 4.2% vs. 0.9%; P < 0.0001). At 1-year follow-up, mortality rate was 48.8% for ESRD, 25.7% for patients with CRF, and 5.5%, for patients without renal dysfunction (P < 0.0001). By multivariate analysis, high left ventricular ejection fraction and creatinine clearance were associated with decreased late mortality (OR = 0.84 and 0.95; P < 0.0001), whereas ESRD (OR = 3.65; P = 0.0002), non-Q-wave myocardial infarction (OR = 2.21; P < 0.0001), diabetes mellitus (OR = 1.99; P < 0.0001), and CRF (OR = 1.74; P = 0.003) were independent correlates of increased late mortality. Therefore, PCI in patients with impaired renal function, whether on dialysis or not, is associated with poor in-hospital and 1-year survival.

Aged↗

Comparison of outcomes after 8 vs. 9.5 French size intra-aortic balloon counterpulsation catheters based on 9,332 patients in the prospective Benchmark registry.

The Benchmark intra-aortic balloon counterpulsation (IABC) registry maintains prospectively gathered clinical information on a large cohort of IABC patients. The purpose of the present report is to compare in-hospital outcomes and complications in patients treated with the newer 8 vs. 9.5 Fr size catheters. Between January 1997 and August 2000, data on 7,078 9.5 Fr and 2,254 8 Fr IABC insertions were submitted to Benchmark. This was not a randomized comparison but rather a posthoc analysis of prospectively gathered data. There was less limb ischemia with the 8 Fr IABC size catheter. There were no significant differences in bleeding or mortality between the two groups. Smaller IABC catheter size is associated with significantly less limb ischemia, especially in higher-risk patients. The large, population-based, ongoing Benchmark registry provides a useful vehicle for outcomes research concerning the evolving practice of IABC.

Aged↗

Trends in intraaortic balloon counterpulsation complications and outcomes in cardiac surgery.

BACKGROUND: As the proportion of high-risk patients for cardiac surgery increases, use of intraaortic balloon counterpulsation (IABC) has increased, especially in preoperative therapy. Although the efficacy and cost-effectiveness of IABC have been demonstrated, historically higher complication rates have dissuaded some practitioners from using IABC. METHODS: This report describes IABC use in cardiac surgery, examines trends in complications over time, and compares outcomes in preoperative versus postoperative use in a single prospective worldwide registry over the past 3 years. RESULTS: The frequency of IABC use appears to be increasing with time as the complication rates have dramatically fallen. The overall IABC-related complication rate was 6.5% (460/7,101), and the rate of major complications (requiring surgery or transfusion) was 2.1% (148/7,101). Hospital mortality was significantly lower in patients treated preoperatively with IABC compared with patients treated postoperatively (8.8% vs 28.2%, p < 0.0001), although this may be due to a selection bias in the postoperative group. CONCLUSIONS: Preoperative IABC therapy leads to better patient outcomes in high-risk CABG patients. Improved IABC technology and better surveillance have led to increased use with lower complication rates. Although selection bias is inherent in retrospective studies, the Benchmark Counterpulsation Outcomes Registry outcomes are in close concordance to prospective randomized studies previously reported.

Cardiac Surgical Procedures↗

New-device angioplasty in women: clinical outcome and predictors in a 7,372-patient registry.

BACKGROUND: Female gender has been identified as an independent predictor of early complications and mortality after conventional balloon angioplasty. To gain insight into the outcome of women after new-device angioplasty, we reviewed the early and late clinical outcome of 7,372 patients undergoing new-device angioplasty between 1991 and 1996 at the Washington Hospital Center. METHODS: Patients (2,077 women and 5,295 men) with native coronary artery (82.5%) or saphenous vein graft lesions undergoing new-device angioplasty were included in the study. In-hospital and 1-year major adverse cardiac events (MACE), including death, myocardial infarction, and target lesion revascularization (TLR), were recorded and compared on the basis of gender. Multivariable logistic regression analysis was performed to identify predictors of in-hospital and late mortality, follow-up MACE, and TLR. RESULTS: Women had more baseline comorbid risk factors and smaller reference vessel size compared with men. Women had a higher in-hospital cardiac mortality (1.39% vs 0.66%, P = 0.002), TLR (2.78% vs 1.81%, P = 0.008), and congestive heart failure (4.18% vs 2.29%, P < 0.001) compared with men. Overall in-hospital MACE tended to be higher among women (4.2% vs 3.3%, P = 0.074). Women had a higher 1-year mortality rate (4.39% vs 3.26%, P = 0.018), but a lower follow-up TLR (15.0% vs 18.1%, P = 0.001) and a lower overall MACE rate (29.2% vs 32.7%, P = 0.007) compared with men. Female gender was an independent predictor of in-hospital mortality (odds ratio 2.28, P = 0.02), but not late mortality. CONCLUSIONS: Although female gender appears to carry an inherent risk of in-hospital mortality after new-device angioplasty, the procedural success and mortality rates are favorable compared with those associated with balloon angioplasty series. The long-term clinical outcome of women after new-device angioplasty is excellent. The use of new devices is a safe and effective alternative strategy for the treatment of women with ischemic coronary artery disease. Device-specific outcomes, including stents, will require further evaluation.

Angioplasty↗

Acute angiographic and clinical results of the NIR w/SOX stent.

Acute angiographic and clinical results of the NIR w/SOX stent (Boston Scientific/Scimed, Inc., Maple Grove, Minnesota) were evaluated. Between March 2000 and May 2000, a total of 102 lesions in 88 patients underwent stenting with the NIR w/SOX stent. The reference vessel diameter and lesion length were 2.97 +/- 0.50 mm and 16.2 +/- 6.5 mm, respectively. The minimal lumen diameter increased from 0.68 +/- 0.45 to 3.07 +/- 0.50 mm. Stent delivery failure was observed in 4 lesions (3.9%). On the other hand, the NIR w/SOX stent was successfully delivered in 7 of 9 lesions that had unsuccessful delivery of other kinds of stents. Angiographic success was observed in all except 1 lesion where the NIR w/SOX stents could not be delivered. There were no procedural myocardial infarctions or deaths. In one case, procedural coronary bypass surgery was performed. There was no acute closure or subacute stent thrombosis. Despite unfavorable lesion characteristics, the NIR w/SOX stent achieves high procedural success and acceptable stent delivery. Furthermore, it may have a high probability to be delivered in lesions where other kinds of stent result in unsuccessful delivery.

Aged↗