Emmetropisation under continuous but non-constant light in chicks.

It has been suggested that ambient lighting at night influences eye growth and might play a causal role in human myopia. To test this hypothesis, we reared newly hatched chicks under 12 hr light-dark or light-dim cycles with a light phase intensity of 1500 microW/cm(2) and variable dim phase intensities between 0.01 and 500 microW/cm(2). Other chicks were reared under constant light conditions with intensities between 1 and 1500 microW/cm(2). After three weeks, the chicks were examined by refractometry, ultrasound and caliper measurements of enucleated eyes. To relate ocular parameters with a retinal neurotransmitter likely involved in eye growth control, retinal and vitreal levels of dopamine and its principal metabolite, 3,4-dihydroxyphenylacetic acid (DOPAC), were measured by high performance liquid chromatography with electrochemical detection in the light, dark and dim phases. Diurnal fluctuations in axial length and choroidal thickness also were measured twice daily by partial coherence interferometry (PCI) in chicks under light-dark and the two brightest light-dim conditions. The eyes of chicks reared under most light-dim conditions had refractions and ocular dimensions comparable to those reared under light-dark conditions. At dim phase light intensities of 10 microW/cm(2) and above, the day-night changes in retinal dopamine metabolism were not observed. The daily fluctuations of axial length and choroidal thickness were altered with rearing under the two brightest dim light intensities, compared to the light-dark condition. Rearing under constant light with intensities ranging between 1 and 1500 microW/cm(2) produced a shallow anterior chamber and other eye alterations previously described for constant light rearing even though rearing under continuous light that fluctuated between these same intensities generally permitted normal eye growth. Thus, continuous but fluctuating light exerts different developmental effects on the eye than constant non-fluctuating light. Light-dim rearing may be more relevant to daily human light exposures than other laboratory lighting conditions and may provide an opportunity to study developmental interactions of visual quality (e.g. blur, defocus, etc.) and features of the light-dark cycle under conditions that perturb daily rhythms in dopamine metabolism and ocular dimensions. Such studies also could provide mechanistic insights into whether and how daily rhythms in retinal dopamine metabolism, axial length or choroidal thickness modulate refractive development.

3,4-Dihydroxyphenylacetic Acid↗

Highly precise eye length measurements in children aged 3 through 12 years.

OBJECTIVE: To determine the feasibility, reliability, and validity of using partial coherence interferometry, a noncontact method that detects interference patterns from various layers of the eye, to measure axial length in young children. METHODS: The right eye of 64 subjects (mean age, 8.4 y; age range, 3.4-12.9 y; best-corrected visual acuity >or=20/30) was measured. Subjects fixated monocularly on the collimated light pattern from a laser diode (the alignment beam) and the operator used a video monitor to align the corneal reflection in the optical path. Axial length was measured during an 0.8-second scan using interference patterns from a collimated short coherence superluminescence diode aligned coaxially with the laser diode. Five series of 16 readings each were obtained. The average axial length for each of the 5 series of readings was calculated. Main Outcome Measure Axial length. RESULTS: Within-subject precision of axial length measurements was high, with an overall SE of measurement of 8 micro m for individual subjects across the 5 sessions (95% confidence interval, +/-16 micro m). Subgroup analysis showed that sex, age, spherical equivalent, and refractive error exerted statistically significant effects on precision, but all of the differences among subgroups were 3 micro m or less and likely to be insignificant clinically. Axial length measured by partial coherence interferometry varied systematically, with factors known to influence eye length (ie, age and refractive error), further validating the measurement method. CONCLUSION: The partial coherence interferometry technique provides reproducible, extraordinarily precise eye length measurements in young children and should enable novel approaches to study eye growth and refractive development.

Body Weights and Measures↗

Variability of retinal steepness at the posterior pole in children 7-15 years of age.

PURPOSE: Considerable evidence suggests that both axial and peripheral refraction play important roles in eye growth control. The large variability in peripheral refraction seen in adults and children indicates that the peripheral retina is exposed to a wide range of refractive errors. The current lack of appropriate measurement techniques has hampered the determination of whether variability in peripheral refraction between individuals can be correlated with variability in retinal steepness. An Optical Low Coherence Reflectometer (OLCR) was developed to determine retinal steepness. METHODS: Retinal steepness was assessed in right eyes of 63 children 7-15 years of age by measuring eye length (EL) and spherical equivalent refraction (SER) axially and at 15 degrees temporally, nasally, inferiorly and superiorly with OLCR and Binocular Auto-Refractometry, respectively, during cycloplegia. At each peripheral location, relative peripheral EL and SER (i.e., the difference between peripheral and axial readings) were compared between myopic, emmetropic and hyperopic eyes, and the correlation between relative peripheral EL and SER was analyzed. RESULTS: Although the standard deviations were large, significant differences in relative peripheral EL and SER between refractive groups as well as a significant correlation between relative peripheral EL and SER were observed at several of the assessed locations. CONCLUSIONS. The results strongly suggest that peripheral refraction is correlated with retinal steepness and that previously observed variability in peripheral refraction chiefly reflects variability in retinal steepness. If peripheral refraction represents a determining parameter in the control of eye growth, the precise measurement of retinal steepness could be used not only to improve estimates of myopic progression, but also to identify children who are at high risk of developing myopia. It may lead to specialized clinical/optical treatments, e.g. the correction of not only axial but also peripheral refractive errors, which are more effective than current treatments in individuals who are at risk of myopia development or progression.

Adolescent↗

Axial and peripheral eye length measured with optical low coherence reflectometry.

An optical low-coherence reflectometer (OLCR device) is described that allows the precise and noncontact measurement of eye length. The device measures eye length both on-axis and off-axis, thus enabling the determination of eye shape, an ocular parameter thought to be important in the development of refractive error. It is essential for several applications in ophthalmology and vision science. This improved OLCR device operates using a single-beam interferometer with a beam deflection mechanism that allows the precise measurement of eye length along the visual axis and within 15 deg horizontally and vertically from the fovea. The validity of this instrument and its revised software is evaluated by measuring the reproducibility of axial length results in an adult eye and an artificial eye, and by correlating axial eye length measured in a group of ten adult eyes with axial eye length obtained with A-scan ultrasound in the same eyes. The precision obtained with adult subjects is compared with that obtained with children.

Adult↗