PubMed Health⌕ Search

Biomedical subjects

Gregor Kadner

Publications and source records attributed to Gregor Kadner.

4 recordsLinked to original sources

Marked reduction and distinct patterns of eye blinking in patients with moderately dry eyes during video display terminal use.

PURPOSE: To analyze the spontaneous eye-blink rate (SEBR) and blinking pattern in patients with moderately dry eyes during video display terminal (VDT) use. METHODS: The SEBR of 30 patients with dry eye syndrome (median age 44.8 years, range 18 - 67 years) was measured using a computer-based video analysis system. Only complete eye blinks were recorded during 10 min of conversation, during initial VDT use and again after a preceding work period of 30 min. RESULTS: In comparison with SEBR during conversation (mean value 16.8 blinks/min, standard deviation 16.8 blinks/min) the SEBR significantly decreased during initial VDT use (6.6+/-4.8; P<0.001) and remained significantly decreased during re-measurement after 30 min (5.9+/-4.6; P<0.001). SEBR was not significantly different between initial VDT use and re-measurement after 30 min ( P=0.65). The SEBR was characterized by marked interindividual variability during conversation and VDT use. No significant correlation was found between SEBR (either during conversation or during VDT use), and the quality (tear break-up time) or quantity (Schirmer I test, Jones test) of the tear film. Typical blinking patterns were found to be (1). a relatively time-independent, irregular pattern, (2). an initial phase of 2-4 min with shorter inter-eye-blink intervals, and (3). alternating periods of higher and lower inter-eye-blink intervals. CONCLUSIONS: Reduction of the SEBR during VDT use is primarily determined by marked visual attention, resulting in an exacerbation of dry eye symptoms in predisposed humans. High interindividual variability and distinct patterns of eye blinking may be key factors in further clarification of VDT-eye interactions and develop individually designed solutions to prevent desiccation during VDT use.

Adolescent↗

Human umbilical cord cells for cardiovascular tissue engineering: a comparative study.

OBJECTIVE: Tissue engineering of viable, autologous cardiovascular replacements with the potential to grow, repair and remodel represents an attractive approach to overcome the shortcomings of available replacements for the repair of congenital cardiac defects. Currently, vascular myofibroblast cells represent an established cell source for cardiovascular tissue engineering. Cell isolation requires the invasive harvesting of venous or arterial vessel segments prior to scaffold seeding, a technique which may not be preferable, especially in pediatric patients. This study evaluates cells isolated from human umbilical cord artery, umbilical cord vein and whole cord as alternative autologous cell sources for cardiovascular tissue engineering. METHODS: Cells were isolated from human umbilical cord artery (UCA), umbilical cord vein (UCV), whole umbilical cord (UCC) and saphenous vein segments (VC), and were expanded in culture. All three expanded cell groups were seeded on bioabsorbable copolymer strips and grown in vitro for 28 days. Isolated cells were characterized by flow cytometry, histology, immunohistochemistry, proliferation assays and compared to VC. Morphological analysis of the seeded polymer strips included histology, immunohistochemistry, sodium dodecyl sulfate-polyacrylamide gel electrophoresis, transmission electron microscopy (TEM), scanning electron microscopy (SEM) and uniaxial stress testing. RESULTS: UCA, UCV and UCC demonstrated excellent cell growth properties comparable to VC. Following isolation, all three cell groups showed myofibroblast-like morphology and characteristics by staining positive for alpha-smooth muscle actin (ASMA) and vimentin. Histology and immunohistochemistry of seeded polymers showed good tissue and extracellular matrix formation containing collagen I, III and elastin. TEM showed viable myofibroblasts and the deposition of collagen fibrils and progressive growing tissue formation, with a confluent surface, was observed in SEM. No difference was found among the mechanical properties of UCA, UCV, UCC and VC tissue engineered constructs. CONCLUSIONS: Tissue engineering of cardiovascular constructs by using UCA, UCV and UCC is feasible in an in vitro environment. Cell growth, morphology, characteristics and tissue formation were comparable between UCA, UCV, UCC and VC. UCC represent an attractive, readily available autologous cell source for cardiovascular tissue engineering offering the additional benefits of utilizing juvenile cells and avoiding the invasive harvesting of intact vascular structures.

Absorbable Implants↗

Characteristics of spontaneous eyeblink activity during video display terminal use in healthy volunteers.

PURPOSE: To analyse the spontaneous eyeblink rate (SEBR) and inter-eyeblink intervals (IEBI) of normal volunteers before and during video display terminal (VDT) use. METHODS: The SEBR of 51 normal volunteers was measured by counting the absence of the corneal reflex using a computer-based video analysis system. Only complete eyeblinks were recorded within 10 min under three different conditions: during a conversation, during VDT use without corneal anaesthesia, and during VDT use with corneal anaesthesia. The IEBI (in seconds) were determined to study individual time-dependent changes of SEBR. RESULTS: In comparison with SEBR during conversation (mean 15.54 eyeblinks/min, standard deviation +/-13.74 eyeblinks/min) the SEBR decreased significantly during VDT use without corneal anaesthesia (5.34 +/- 4.53 eyeblinks/min). Corneal anaesthesia further significantly reduced SEBR (2.78 +/- 2.77 eyeblinks/min). The SEBR was characterized by marked interindividual variability, ranging between 11 and 664 eyeblinks/10 min during conversation, between 4 and 189 eyeblinks during VDT use without corneal anaesthesia and between 1 and 119 eyeblinks at VDT use with corneal anaesthesia. No significant correlation between SEBR (during conversation or during VDT use) and quality (break-up time) or quantity (Schirmer I test, Jones test) of the tear film could be detected. Evaluation of the IEBI revealed three different types of eyeblink pattern during VDT use without corneal anaesthesia. Type 1 was characterized by a very low SEBR (0-2 eyeblinks/min) and relatively homogeneous distribution of eyeblinks, type 2 showed a moderate SEBR (1.2-8.5 eyeblinks/min) including three further subtypes. Type 3 was characterized by a high SEBR (6.8-18.9 eyeblinks/min) of regular or irregular pattern. CONCLUSIONS: VDT use is associated with a profound decrease of the SEBR in healthy subjects. There are marked interindividual differences in SEBR and no correlation between the SEBR and ocular tear film parameters in normal eyes. The SEBR is further reduced by corneal anaesthesia. The presence of different patterns of eyeblinking may be related to various exogenous and endogenous factors and may lead to a better understanding of ocular reactions during VDT use.

Adult↗

Human umbilical cord cells: a new cell source for cardiovascular tissue engineering.

BACKGROUND: Tissue engineering of viable, autologous cardiovascular constructs with the potential to grow, repair, and remodel represents a promising new concept for cardiac surgery, especially for pediatric patients. Currently, vascular myofibroblast cells (VC) represent an established cell source for cardiovascular tissue engineering. Cell isolation requires the invasive harvesting of venous or arterial vessel segments before scaffold seeding, a technique that may not be preferable, particularly in pediatric patients. In this study, we investigated the feasibility of using umbilical cord cells (UCC) as an alternative autologous cell source for cardiovascular tissue engineering. METHODS: Human UCC were isolated from umbilical cord segments and expanded in culture. The cells were sequentially seeded on bioabsorbable copolymer patches (n = 5) and grown in vitro in laminar flow for 14 days. The UCC were characterized by flow cytometry (FACS), histology, immunohistochemistry, and proliferation assays and were compared to saphenous vein-derived VC. Morphologic analysis of the UCC-seeded copolymer patches included histology and both transmission and scanning electron microscopy. Characterization of the extracellular matrix was performed by immunohistochemistry and quantitative extracellular matrix protein assays. The tissue-engineered UCC patches were biomechanically evaluated using uniaxial stress testing and were compared to native tissue. RESULTS: We found that isolated UCC show a fibroblast-like morphology and superior cell growth compared to VC. Phenotype analysis revealed positive signals for alpha-smooth muscle actin (ASMA), desmin, and vimentin. Histology and immunohistochemistry of seeded polymers showed layered tissue formation containing collagen I, III, and glycoaminoglycans. Transmission electron microscopy showed viable myofibroblasts and the deposition of collagen fibrils. A confluent tissue surface was observed during scanning electron microscopy. Glycoaminoglycan content did not reach values of native tissue, whereas cell content was increased. The biomechanical properties of the tissue-engineered constructs approached native tissue values. CONCLUSIONS: Tissue engineering of cardiovascular constructs using UCC is feasible in an in vitro environment. The UCC demonstrated excellent growth properties and tissue formation with mechanical properties approaching native tissue. It appears that UCC represent a promising alternative autologous cell source for cardiovascular tissue engineering, offering the additional benefits of using juvenile cells and avoiding the invasive harvesting of intact vascular structures.

Actins↗