PubMed Health⌕ Search

Biomedical subjects

Gregor Liebsch

Publications and source records attributed to Gregor Liebsch.

3 recordsLinked to original sources

In vivo phosphorescence imaging of pO2 using planar oxygen sensors.

OBJECTIVE: Oxygen-dependent quenching of luminescence of metal porphyrin complexes has been used to image the pO(2) distribution over tumor and normal tissue. METHODS: An experimental setup is described using a platinum(II)-octaethyl-porphyrin immobilized in a polystyrene matrix as transparent planar sensor. RESULTS: Sensitivity over a broad range is high at low pO(2) values (+/- 0.2 mm Hg at 0 mm Hg; +/- 1.5 mm Hg at 160 mm Hg pO(2)). Due to intrinsically referencing via lifetime encoding there was no modification of the sensor response in vivo in the dorsal skinfold chamber model with amelanotic melanoma (A-MEL-3) in awake hamsters when compared to the in vitro calibration. pO(2) measurements over normal tissue (25.8 +/- 5.1 mm Hg) and tumor tissue (9.2 +/- 5.1 mm Hg) were in excellent agreement with previous results obtained in this model using a surface multiwire electrode. CONCLUSIONS: Using the presented method the surface pO(2) distribution can be mapped with a high temporal resolution of approximately 100 ms and a spatial resolution of at least 25 mu m. Moreover, the transparent sensor allows the simultaneous visualization of the underlying microvasculature.

Animals↗

Cross-reactive metal ion sensor array in a micro titer plate format.

A cross-reactive array in a micro titer plate (MTP) format is described that is based on a versatile and highly flexible scheme. It makes use of rather unspecific metal ions probes having almost identical fluorescence spectra, thus enabling (a) interrogation at identical analytical wavelengths, and (b) imaging of the probes contained in the wells of the MTP using a CCD camera and an array of blue-light-emitting diodes as a light source. The unselective response of the indicators in the presence of mixtures of five divalent cations generates a characteristic pattern that was analyzed by chemometric tools. The fluorescence intensity of the indicators was transferred into a time-dependent parameter applying a scheme called dual lifetime referencing. In this method, the fluorescence decay profile of the indicator is referenced against the phosphorescence of an inert reference dye added to the system. The intrinsically referenced measurements also were performed using blue LEDs as light sources and a CCD camera without intensifiers as the detector. The best performance was observed if each well was excited by a single LED. The assembly allows the detection of dye concentrations in the nanomoles-per-liter range without amplification and the acquisition of 96 wells simultaneously. The pictures obtained form the basis for evaluation by pattern recognition algorithms. Support vector machines are capable of predicting the presence of significant concentrations of metal ions with high accuracy.

Journal Article↗

Determination of oxygen gradients in engineered tissue using a fluorescent sensor.

Nutrient and oxygen supply of cells are crucial to tissue engineering in general. If a sufficient supply cannot be maintained, the development of the tissue will slow down or even fail completely. Previous studies on oxygen supply have focused on measurement of oxygen partial pressures (pO(2)) in culture media or described the use of invasive techniques with spatially limited resolution. The experimental setup described here allows for continuous, noninvasive, high-resolution pO(2) measurements over the cross-section of cultivated tissues. Applying a recently developed technique for time-resolved pO(2) sensing using optical sensor foils, containing luminescent O(2)-sensitive indicator dyes, we were able to monitor and analyze gradients in the oxygen supply in a tissue over a 3-week culture period. Cylindrical tissue samples were immobilized on top of the sensors. By measuring the luminescence decay time, two-dimensional pO(2) distributions across the tissue section in contact with the foil surface were determined. We applied this technique to cartilage explants and to tissue-engineered cartilage. For both tissue types, changes were detected in monotonously decreasing gradients of pO(2) from the surface with high pO(2) to minimum pO(2) values in the center of the samples. Nearly anoxic conditions were observed in tissue constructs ( approximately 0 Torr) but not in excised cartilage discs ( approximately 20 Torr) after 1 day. Furthermore, the oxygen supply seemed to strongly depend on cell density and cell function. Additionally, histological analysis revealed a maximum depth of approximately 1.3 mm of regular cartilage development in constructs grown under the applied culture conditions. Correlating analytical and histological analysis with the oxygen distributions, we found that pO(2) values below 11 Torr might impair proper tissue development in the center. The results illustrate that the method developed is an ideal one to precisely assess the oxygen demand of cartilage cultures.

Animals↗