BACKGROUND: The multibite biopsy forceps is intended for consecutive acquisition of numerous tissue specimens with a single pass. The Pelican multibite forceps is equipped with a sleeve for tissue retention that allows up to 6 specimens to be obtained with each pass of the device through the accessory channel. Reducing the need for device exchange could decrease the total procedure time for colon cancer surveillance in patients with longstanding inflammatory bowel disease (IBD). OBJECTIVE: The aim of this study was to evaluate a new multibite biopsy forceps in comparison with a standard double-bite forceps. DESIGN: Prospective randomized animal model trial. SETTING: Multicenter university and community hospitals. INTERVENTIONS: By using a live porcine model, multiple colonoscopic biopsy specimens were obtained with both the Pelican multibite forceps and the Radial Jaw 3 (RJ3) double-bite forceps to mimic colorectal cancer surveillance in patients with IBD. Six biopsy specimens were obtained with each of 6 passes when using the Pelican forceps, and 2 biopsy specimens were obtained with each of 18 passes when using the RJ3 forceps. MAIN OUTCOME MEASUREMENTS: All trials were timed. Two independent pathologists blinded to the forceps used evaluated the specimens. RESULTS: Tissue acquisition when using the Pelican multibite forceps was significantly faster than with a standard double-bite forceps. The devices compared equivalently for specimen retention and quality. LIMITATIONS: The operator could not be blinded to the devices used. This study uses an animal model to extrapolate how the devices might perform in human use. CONCLUSIONS: These findings support the evaluation of the Pelican forceps for colon cancer surveillance in patients with longstanding IBD.
Over the past decade, the application of anticoagulant and antiplatelet agents for various cardiovascular and hematologic conditions has become more widespread. Optimal management of these agents during the periendoscopic period requires consideration, but limited prospective data mean that guidelines have largely relied on expert opinion. Elective procedures should be delayed in patients on temporary anticoagulation therapy (e.g. those with deep vein thrombosis). For procedures considered to have a low risk of bleeding (e.g. diagnostic endoscopy and colonoscopy without polypectomy) there is no need to discontinue or adjust anticoagulation. For procedures with a higher risk of bleeding (e.g. polypectomy and biliary sphincterotomy) an individual approach is required. This approach might include stopping oral anticoagulant therapy with or without the administration of unfractionated heparin or low-molecular-weight heparin for the preprocedure and postprocedure periods, during which the patient's international normalized ratio is in the subtherapeutic range.
OBJECTIVE: The purpose of this report is to assess the findings on esophagography in patients with esophageal stents for palliation of malignant tumors involving the esophagus. CONCLUSION: Radiologists should be familiar with findings of little importance (stent narrowing, flow of contrast medium around stent, stent kinks, and apparent esophageal narrowing below stent because of incompletely distended hiatal hernias) versus more important findings (polypoid defects above or below stent, narrowing within or below stent, delayed stent emptying, esophageal-airway fistulas, stent migration, and abutting of distal stent against greater curvature of stomach) on esophagography after stent placement to guide endoscopists regarding the need for stent revision.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
BACKGROUND AND AIMS: It is unknown how physician specialties other than gastroenterologists that manage gastrointestinal (GI) malignancies utilize endoscopic ultrasound (EUS) in their practices. The aim of this study was to (i) assess the proportion of gastroenterologists, oncologists, and surgeons that utilize EUS for staging of GI malignancies; (ii) assess the general availability of EUS; and (iii) determine which factors are associated with the use and availability of EUS. METHODS: A self-administered questionnaire was mailed out to 1,200 randomly selected gastroenterologists, oncologists, and surgeons throughout the United States. RESULTS: The data was analyzed from 521 (43%) responses. There were 60% respondents who had EUS available within their practices. There was greater availability of EUS within the practices of surgeons (81%; p < 0.001), within academic practices (87%; p= < 0.001), and in practices that serve a population >500,000 (p < 0.001). The majority of respondents (71%) utilized EUS in their practices. There was a similar utilization of EUS across specialties (p= NS). There was greater utilization of EUS in academic centers (82%; p < 0.001), in practices that served a community of >500,000 (p= 0.003), and among respondents who had been in practice for less than 5 yr (p= 0.005). Employing logistic regression models for utilization of EUS, lesser number of years in practice, and availability of EUS were found to be the only significant predictors of utilization. CONCLUSIONS: The majority of practitioners utilized EUS in management of GI malignancies. There was similar utilization of EUS across specialties. EUS is available to the majority of practitioners who manage GI malignancies.
Explore the source record for details and available documents.
This section focuses on intraprocedural steps that can improve endoscopic efficiency. Contributors to procedural efficiency and inefficiency are considered. The limitations to enhancing efficiency are presented. Strategies for incorporating contributors to efficiency including techniques, technologies, accessories, and attitudes are presented.
BACKGROUND: Acute pancreatitis remains a serious cause of ERCP-related morbidity. Topical application of lidocaine reportedly blunts cholecystokinin release from intestinal mucosa and reduces sphincter of Oddi spasm. A randomized trial was conducted to evaluate the effect of lidocaine sprayed on the major duodenal papilla on the frequency of post-ERCP pancreatitis. Secondary outcomes evaluated were ease of cannulation and severity of post-ERCP pancreatitis. METHODS: Patients undergoing ERCP were randomized in blocks of 6 to have 10 mL of either 1% lidocaine or normal saline solution sprayed on the major papilla before cannulation. Patients were observed for the development of post-ERCP pancreatitis. Patient history- and procedure-related variables were recorded. RESULTS: A total of 326 patients were enrolled, of whom 32 were excluded after randomization but before analysis. Of patients analyzed, 145 were randomized to treatment with lidocaine and 149 to placebo. No patient was lost to follow-up. There was no significant difference noted in patient history- or procedure-related variables. Seven patients in the lidocaine group and 5 in the placebo group developed post-ERCP pancreatitis (p=0.73). Ease of cannulation did not differ between the two groups. CONCLUSIONS: Lidocaine sprayed on the major papilla does not decrease the frequency of post-ERCP pancreatitis.
Explore the source record for details and available documents.
BACKGROUND: Catheter/guidewire exchanges during ERCP require the coordinated efforts of an endoscopist and endoscopy assistant. A prototype duodenoscope was developed to improve the control of catheter/guidewire exchange by enabling fixation of guidewires at the elevator lever. METHODS: An initial prototype duodenoscope and a subsequent modification of this instrument were used to perform ERCP in 7 and 10 patients, respectively. The following were recorded: total procedure time, fluoroscopy time, catheter/guidewire exchange time, guidewire repositioning, loss of guidewire access, success or failure of fixation, and endoscopist satisfaction. OBSERVATIONS: The initial and the modified prototype duodenoscopes were used in a variety of catheter/guidewire exchanges (n=46). Guidewire fixation was achieved in 75% of catheter/guidewire exchanges with the initial prototype and in 93% with the modified prototype and was reflected in shorter exchange times. Access to the desired duct was not lost during any exchange, and the need for repositioning was eliminated. CONCLUSIONS: A new prototype duodenoscope with an elevator lever that enables guidewire fixation will improve the ease and efficiency of catheter/guidewire exchange during ERCP. Modifications made to the original prototype improved reliability of guidewire fixation.
BACKGROUND: The aim of this study was to determine the frequency and the severity of pancreatitis after EUS-guided FNA of solid pancreatic masses. A survey of centers that offer training in EUS in the United States was conducted. METHODS: A list of centers in which training in EUS is offered was obtained from the Web site of the American Society for Gastrointestinal Endoscopy. Designated program directors were contacted via e-mail. The information requested included the number of EUS-guided FNA procedures performed for solid pancreatic masses, the number of cases of post-procedure pancreatitis, and the method for tracking complications. For each episode of pancreatitis, technical details were obtained about the procedure, including the location of the mass, the type of fine needle used, the number of needle passes, and the nature of the lesion. RESULTS: Nineteen of the 27 programs contacted returned the questionnaire (70%). In total, 4909 EUS-guided FNAs of solid pancreatic masses were performed in these 19 centers over a mean of 4 years (range 11 months to 9 years). Pancreatitis occurred after 14 (0.29%): 95% CI[0.16, 0.48] procedures. At two centers in which data on complications were prospectively collected, the frequency of acute pancreatitis was 0.64%, suggesting that the frequency of pancreatitis in the retrospective cohort (0.26%) was under-reported (p=0.22). The odds that cases of pancreatitis would be reported were 2.45 greater for the prospective compared with the retrospective cohort (95% CI[0.55, 10.98]). The median duration of hospitalization for treatment of pancreatitis was 3 days (range 1-21 days). The pancreatitis was classified as mild in 10 cases, moderate in 3, and severe in one; one death (proximate cause, pulmonary embolism) occurred after the development of pancreatitis in a patient with multiple comorbid conditions. CONCLUSIONS: EUS-guided FNA of solid pancreatic masses is infrequently associated with acute pancreatitis. The procedure appears to be safe when performed by experienced endosonographers. The frequency of post EUS-guided FNA pancreatitis may be underestimated by retrospective analysis.
BACKGROUND & AIMS: There are limited data evaluating the clinical impact of endoscopic ultrasonography (EUS). We assessed the impact of EUS on management of known or suspected malignancies. METHODS: Physicians requesting EUS were contacted before the examination and asked: "How would you manage this patient if EUS were not available?" Pre-EUS responses were recorded on standardized forms, and compared with management recommendations as determined by the same requesting physician after EUS. Endosonographers performing the study were blinded to the pre-EUS responses. RESULTS: Responses were obtained from requesting physicians before and after EUS in 90 patients. Requesting physicians were composed of surgeons (33%), non-EUS-performing gastroenterologists (58%), oncologists (3%), internists (4%), and a pulmonologist (1%). After EUS, referring clinicians altered management plans in 46 of 90 patients (51%). By anatomic site, management changes occurred in 12 of 22 patients (56%) undergoing esophageal EUS, 9 of 15 (60%) undergoing gastric EUS, 21 of 43 (49%) undergoing pancreatic EUS, and 4 of 10 (40%) undergoing rectal EUS. There were no significant differences in the frequency of post-EUS management changes with respect to examination site (P = .76). EUS fine-needle aspiration (FNA) altered management in 9 of 20 (45%) patients. Management changes involved less complex or decreased risk-associated approaches in the majority (70%), and included 14 of 50 (28%) patients in whom surgical procedures were no longer planned. CONCLUSIONS: Based on EUS examination findings, clinicians requesting EUS alter patient management in one half of cases, and more often pursue a less-complicated approach. EUS substantially impacts clinical care, and should be used in appropriate settings to guide patient management.
Our purpose was to determine the prevalence of Barrett's esophagus in the presence of Schatzki ring. We performed a retrospective case-control study with an endoscopic database. Barrett's esophagus was present in 3 of 409 (0.73%) patients with Schatzki ring and in 16 of 888 (1.80%) patients without Schatzki ring. Short segment Barrett's esophagus was present in 3 cases and 10 controls. Long segment Barrett's esophagus was present in no cases and six controls. Logistic regression models adjusting for the presence of a hiatal hernia revealed a significant decrease in the odds of Barrett's esophagus in cases compared to controls (OR, 0.24; 95% CI, 0.07-0.87; P = 0.029). Barrett's esophagus is less prevalent in patients with Schatzki ring compared to patients without Schatzki ring. Long segment Barrett's esophagus was not observed in patients with Schatzki ring. A responsible protective effect or mutually exclusive pathophysiology should be considered.