Diagnostic fidelity of the Z-buffer segmentation algorithm: preliminary assessment based on intracranial aneurysm detection.

We have developed an algorithm known as the Z-buffer segmentation (ZBS) algorithm for segmenting vascular structures from 3D MRA images. Previously we evaluated the accuracy of the ZBS algorithm on a voxel level in terms of inclusion and exclusion of vascular and background voxels. In this paper we evaluate the diagnostic fidelity of the ZBS algorithm. By diagnostic fidelity we mean that the data preserves the structural information necessary for diagnostic evaluation. This evaluation is necessary to establish the potential usefulness of the segmentation for improved image display, or whether the segmented data could form the basis of a computerized analysis tool. We assessed diagnostic fidelity by measuring how well human observers could detect aneurysms in the segmented data sets. ZBS segmentation of 30 MRA cases containing 29 aneurysms was performed. Image display used densitometric reprojections with shaded surface highlighting that were generated from the segmented data. Three neuroradiologists independently reviewed the generated ZBS images for aneurysms. The observers had 80% sensitivity (90% for aneurysms larger than 2mm) with 0.13 false positives per image. Good agreement with the gold standard for describing aneurysm size and orientation was shown. These preliminary results suggest that the segmentation has diagnostic fidelity with the original data and may be useful for improved visualization or automated analysis of the vasculature.

Algorithms↗

High-resolution time-resolved contrast-enhanced 3D MRA by combining SENSE with keyhole and SLAM strategies.

Sensitivity encoding (SENSE) was combined with keyhole and selective line acquisition mode (SLAM) techniques to acquire a time series of images during contrast passage. The acquisition speed of the dynamic time frames was improved by a factor of 8 in total. The high spatial frequencies were sampled during the steady state and combined with the dynamic time frames to construct a series of high-resolution time-resolved contrast-enhanced 3D images. Filtered temporal correlation analysis was used to separate the arteries and veins.

Carotid Arteries↗

A methodology and implementation for annotating digital images for context-appropriate use in an academic health care environment.

Use of digital medical images has become common over the last several years, coincident with the release of inexpensive, mega-pixel quality digital cameras and the transition to digital radiology operation by hospitals. One problem that clinicians, medical educators, and basic scientists encounter when handling images is the difficulty of using business and graphic arts commercial-off-the-shelf (COTS) software in multicontext authoring and interactive teaching environments. The authors investigated and developed software-supported methodologies to help clinicians, medical educators, and basic scientists become more efficient and effective in their digital imaging environments. The software that the authors developed provides the ability to annotate images based on a multispecialty methodology for annotation and visual knowledge representation. This annotation methodology is designed by consensus, with contributions from the authors and physicians, medical educators, and basic scientists in the Departments of Radiology, Neurobiology and Anatomy, Dermatology, and Ophthalmology at the University of Utah. The annotation methodology functions as a foundation for creating, using, reusing, and extending dynamic annotations in a context-appropriate, interactive digital environment. The annotation methodology supports the authoring process as well as output and presentation mechanisms. The annotation methodology is the foundation for a Windows implementation that allows annotated elements to be represented as structured eXtensible Markup Language and stored separate from the image(s).

Academic Medical Centers↗

The need for phase-encoding flow compensation in high-resolution intracranial magnetic resonance angiography.

PURPOSE: To demonstrate that the time delay between phase and frequency encoding and the presence of pulsatile blood flow in high-resolution time-of-flight (TOF) imaging of the intracranial arteries (especially near the circle of Willis) can distort the appearance of blood vessels and result in a cross-hatch-appearing artifact in surrounding tissue. MATERIALS AND METHODS: Two techniques to reduce the artifact, tri-directional flow compensation (3DFC) and elliptical-centric (EC) phase-encoding order, are investigated in five volunteer studies. RESULTS: 3DFC eliminates the pulsation-related artifacts and the vessel distortion. A residual amplitude variation artifact is observed. EC phase encoding nearly eliminates the pulsatile motion-related artifact, but it does not eliminate vessel distortion. CONCLUSION: The combination of 3DFC and EC phase encoding appears to provide the greatest artifact reduction in the five volunteer studies performed.

Adult↗

CD/DVD technology.

For storage of large amounts of data, there are many options to consider, including both CD and DVD methods. Given that these are now becoming very cheap alternatives, and that we work in a specialty which generates large volumes of digital data, it is now obvious why CD and DVD burning is of interest to radiologists. These technologies can most assuredly be of great benefit to both our professional and personal lives.

CD-ROM↗

Improved efficiency in double-inversion fast spin-echo imaging.

Double-inversion fast spin-echo (FSE) pulse sequences can be designed to provide excellent suppression of blood signal in black-blood MRI. However, because a nonselective inversion is used, these sequences typically have been highly inefficient. In this work it is demonstrated that the efficiency of double-inversion sequences can be greatly improved by a form of interleaving in which all of the slices to be imaged in a single pass are reinverted each time a signal is obtained from any single slice. To date, several studies have demonstrated a high level of blood suppression with these more efficient techniques.

Aged↗

Magnetoencephalographically directed review of high-spatial-resolution surface-coil MR images improves lesion detection in patients with extratemporal epilepsy.

PURPOSE: To determine whether (a) interictal magnetoencephalographic (MEG) epileptiform activity corresponds to anatomic abnormalities at magnetic resonance (MR) imaging, (b) high-spatial-resolution MR imaging depicts lesions in regions without MEG spike activity, (c) MEG-directed review of high-spatial-resolution MR images enables detection of abnormalities not apparent on conventional MR images, and (d) MEG information results in a greater number of diagnosed lesions at re-review of conventional MR images. MATERIALS AND METHODS: Twenty patients with neocortical epilepsy were evaluated with MEG, conventional brain MR imaging with a head coil, and high-spatial-resolution MR imaging with either a surface coil (n = 17) or a high-spatial-resolution birdcage coil (n = 3). Abnormal MEG foci were compared with corresponding anatomic areas on conventional and high-spatial-resolution MR images to determine the presence (concordance) or absence (discordance) of anatomic lesions corresponding to foci of abnormal MEG activity. RESULTS: Forty-four epileptiform MEG foci were identified. Twelve foci (27%) were concordant with an anatomic abnormality at high-spatial-resolution MR imaging, and 32 foci (73%) were discordant. Results of high-spatial-resolution MR imaging were normal in eight patients, and 23 lesions were detected in the remaining 12 patients. Twelve lesions (52%) were concordant with abnormal MEG epileptiform activity, and 11 (48%) were discordant (ie, there was normal MEG activity in the region of the anatomic abnormality). At retrospective reevaluation of conventional MR images with MEG guidance, four occult gray matter migration lesions that had initially been missed were observed. An additional patient with MEG-concordant postoperative gliosis was readily identified with high-spatial-resolution MR images but not with conventional MR images. CONCLUSION: Review of MEG-localized epileptiform areas on high-spatial-resolution MR images enables detection of epileptogenic neocortical lesions, some of which are occult on conventional MR images.

Adult↗