Panoramic optical mapping reveals continuous epicardial reentry during ventricular fibrillation in the isolated swine heart.

During ventricular fibrillation (VF), activation waves are fragmented and the heart cannot contract synchronously. It has been proposed that VF waves emanate from stable sources ("mother rotors"). Previously, we used new optical mapping technology to image VF wavefronts from nearly the entire epicardial surface of six isolated swine hearts. We found that VF was not driven by epicardial rotors, but could not exclude the presence of stable rotors hidden within the ventricular walls. Here, we use graph theoretic analysis to show that, in all 17 VF episodes we analyzed, it was always possible to trace sequences of wavefronts through series of fragmentation and collision events from the beginning to the end of the episode. The set of wavefronts that were so related (the dominant component) consisted of 92%+/-1% of epicardial wavefronts. Because each such wavefront sequence constitutes a continuous activation front, this finding shows that complete reentrant pathways were always present on the epicardial surface and therefore, that wavefront infusion from nonepicardial sources was not strictly necessary for VF maintenance. These data suggest that VF in this model is not driven by localized sources; thus, new anti-VF treatments designed to target such sources may be less effective than global interventions.

Action Potentials↗

Lifetimes of epicardial rotors in panoramic optical maps of fibrillating swine ventricles.

During ventricular fibrillation (VF), electrical activation waves are fragmented, and the heart cannot contract in synchrony. It has been proposed that VF waves emanate from stable periodic sources (often called "mother rotors"). The objective of the present study was to determine if stable rotors are consistently present on the epicardial surface of hearts comparable in size to human hearts. Using new optical mapping technology, we imaged VF from nearly the entire ventricular surface of six isolated swine hearts. Using newly developed pattern analysis algorithms, we identified and tracked VF wave fronts and phase singularities (PS; the pivot point of a reentrant wave front). We introduce the notion of a compound rotor in which the rotor's central PS can change and describe an algorithm for automatically identifying such patterns. This prevents rotor lifetimes from being inappropriately abbreviated by wave front fragmentation and collision events near the PS. We found that stable epicardial rotors were not consistently present during VF: only 1 of 17 VF episodes contained a compound rotor that lasted for the entire mapped interval of 4 s. However, shorter-lived rotors were common; 12.2 (SD 3.3) compound rotors with lifetime >200 ms were visible on the epicardium at any given instant. We conclude that epicardial mother rotors do not drive VF in this experimental model; if mother rotors do exist, they are intramural or septal. This paucity of persistent rotors suggests that individual rotors will eventually terminate by themselves and therefore that the continual formation of new rotors is critical for VF maintenance.

Algorithms↗

Chronic myocardial infarction is a substrate for bradycardia-induced spontaneous tachyarrhythmias and sudden death in conscious animals.

INTRODUCTION: Patients with bradycardia can have severe tachyarrhythmias but it is unclear whether bradycardia alone can induce arrhythmias or whether an additional substrate is necessary. While several animal models of ventricular tachycardia (VT) exist, no model has been reported to mimic the clinical condition of spontaneous VT and sudden cardiac death (SCD) in the presence of bradycardia and chronic myocardial infarction (MI) in large animals without manipulation of the autonomic nervous system. We tested the hypothesis that MI and bradycardia cause more spontaneous sustained VT than does bradycardia alone. METHODS AND RESULTS: Sheep (42-56 kg) underwent atrioventricular (AV) node catheter ablation alone (n = 5) or AV node ablation and 150 minutes of angioplasty balloon occlusion of the left anterior descending coronary artery (n = 9). An implantable cardioverter defibrillator delivered rescue shocks and demand pacing at 90 beats per minute for the first week and at 40 beats per minute thereafter. Electrograms were continuously radiotelemetered and recorded for 6 weeks. Acute post-MI VT disappeared by day 4. The sudden bradycardia on day 8 triggered numerous premature ventricular contractions (PVCs) and episodes of sustained VT lasting >30 seconds during the next 5 weeks. There were 43 episodes of sustained VT and no spontaneous ventricular fibrillation (VF) with bradycardia alone. However, in the presence of both MI and bradycardia there were 970 episodes of VT/VF (P < 0.05) and three deaths at days 13, 15, and 34. The average 24-hour count of PVCs was similar at day 7 between the two groups but by days 11 and 40, the PVC counts were 35 times and 4 times greater, respectively, in the presence of bradycardia and chronic MI compared to bradycardia alone. No significant difference in the incidence of PVCs was detected because of large individual variation between the two groups (P = 0.21). A high PVC count did not appear to predict SCD. CONCLUSION: The combination of MI and bradycardia secondary to AV node ablation in sheep produces a higher incidence of VT than bradycardia alone, suggesting that this preparation can serve as a model for the study of VT and sudden cardiac death.

Animals↗

Mechanisms for the maintenance of ventricular fibrillation: the nonuniform dispersion of refractoriness, restitution properties, or anatomic heterogeneities?

INTRODUCTION: The relative importance of nonuniform dispersion of refractoriness, steep restitution slopes, and anatomic heterogeneities in causing conduction block during ventricular fibrillation (VF) remains unknown. METHODS AND RESULTS: In six open-chest pigs, ventricular refractoriness and restitution curves were estimated from activation recovery intervals (ARIs) calculated from 504 (21 x 24) unipolar electrode recordings 2 mm apart in a plaque sutured to the left ventricular (LV) free wall. A steady-state restitution protocol was performed twice at each of two pacing sites: the LV base and near the left anterior descending artery. VF was electrically induced four times and the incidence of conduction block at each electrode during the first 20 seconds was determined by an automated algorithm. The gradient of the ARI was calculated at each electrode to estimate the spatial dispersion of refractoriness. An exponential curve was fit to the restitution plots of ARIs versus the corresponding diastolic intervals (DIs) for all pacing cycle lengths at each electrode. The locations of epicardial blood vessels were noted after the study. Spatial patterns of conduction block were significantly correlated between the four VF episodes in the same animal (r = 0.66 +/- 0.07, P < 0.05). At the shortest pacing cycle length, the spatial distribution of ARIs, ARI gradients, and restitution slopes was not random but formed clusters of similar values. However, none of these variables was significantly correlated with the incidence of conduction block, even though ARI gradients >2 msec/mm were present between many clusters and approximately 90% of restitution slopes were >1. Instead, conduction block frequently appeared to cluster along epicardial vessels. CONCLUSION: Neither the dispersion of refractoriness nor action potential duration restitution determined during rapid pacing by itself is the major determinant of the location of conduction block during early VF in normal pigs. It may be that these factors interact synergistically with each other as well as with other factors, including anatomic heterogeneities such as those caused by blood vessels, which may be particularly important for the formation of conduction block and maintenance of VF.

Animals↗

Evidence that activation following failed defibrillation is not caused by triggered activity.

BACKGROUND: Earliest postshock activation following failed defibrillation shocks slightly lower than the defibrillation threshold (DFT) in large animals appears to arise from a focus. We tested the hypothesis that these foci are caused by early or delayed afterdepolarizations (EADs or DADs) by performing epicardial electrical mapping and giving the EAD inhibitor pinacidil or the DAD inhibitor flunarizine to see if the foci were extinguished or altered in timing or location. METHODS AND RESULTS: A sock containing 504 electrodes was placed over the entire ventricular epicardium of 12 open-chested pigs. After the DFT was determined and additional shocks given, pinacidil was administered to 6 pigs and flunarizine to 6 pigs. Then, the DFT was again determined and additional shocks were given. Pinacidil significantly shortened the effective refractory period (ERP) (162 +/- 16 vs 130 +/- 28 msec) and action potential duration (APD(90)) (179 +/- 6 vs 149 +/- 19 msec) and significantly increased the peak frequency of the power spectrum of a left ventricle (LV) electrode during ventricular fibrillation (VF) (9.3 +/- 0.6 vs 10.5 +/- 1.0 Hz), while flunarizine did not significantly alter the ERP (162 +/- 8 vs 167 +/- 18 msec) or APD(90) (187 +/- 12 vs 191 +/- 20) but significantly reduced the peak frequency (9.2 +/- 0.5 vs 7.5 +/- 1.0 Hz). These findings suggest the drugs had their expected electrophysiological effects. However, the DFT was not significantly changed by either drug. Following the same strength shock 10% below the predrug DFT, earliest postshock activation arose in a focal epicardial pattern from the anterior-apical LV both before and after the drugs. The time from the shock until the appearance of this activation was not significantly different before and after either drug. CONCLUSION: The lack of change in DFT as well as the lack of change in the incidence, location, and timing of the postshock focus with sub-DFT strength shocks before and after pinacidil and flunarizine provide evidence that these foci are not caused by triggered activity.

Analysis of Variance↗

Short-acting beta-adrenergic antagonist esmolol given at reperfusion improves survival after prolonged ventricular fibrillation.

BACKGROUND: High catecholamine concentrations are cytotoxic to cardiac myocytes. We hypothesized that myocardial interstitial catecholamine levels are greatly elevated immediately after long-duration ventricular fibrillation (VF), defibrillation, and reperfusion and that the short-acting beta-antagonist esmolol administered at reperfusion would protect against this catecholamine surge and improve survival. METHODS AND RESULTS: In part 1 of this study, catecholamines from myocardial interstitial fluid (ISF) and aortic and coronary sinus plasma were quantified by use of 3H-labeled radioenzymatic assay in 8 open-chest, anesthetized pigs. Eight minutes of electrically induced VF was followed by internal defibrillation and reperfusion. By 4 minutes of VF, ISF norepinephrine increased significantly, from 1.3+/-0.3 to 7.4+/-2.4 ng/mL. Epinephrine increased significantly, from 0.4+/-0.2 to 1.5+/-0.7 ng/mL. ISF norepinephrine and epinephrine peaked at 219.2+/-92.1 and 63.7+/-25.1 ng/mL after defibrillation and reperfusion and decreased significantly to 12.2+/-3.5 and 6.7+/-3.1 ng/mL 23 minutes after defibrillation. Transcardiac catecholamine changes were similar. In part 2, 8 minutes of VF was followed by external defibrillation in anesthetized, closed-chest pigs. Animals received 1.0 mg/kg esmolol (n=8) or saline (n=8) intravenously at the start of cardiopulmonary resuscitation (CPR). Advanced cardiac life support, including CPR and epinephrine, was delivered to both groups. Esmolol before reperfusion improved return of spontaneous circulation and 4-hour survival (7/8 versus 3/8 survivors, chi2 P<0.05). CONCLUSIONS: Transcardiac and ISF norepinephrine and epinephrine levels are briefly massively elevated after 8 minutes of VF, defibrillation, and reperfusion. A short-acting beta-antagonist administered immediately after defibrillation improves return of spontaneous circulation and 4-hour survival after this prolonged VF.

Adrenergic beta-Antagonists↗

Epicardial organization of human ventricular fibrillation.

OBJECTIVE: The objective of this study was to test the hypothesis that on the epicardium of the in vivo human heart, ventricular fibrillation (VF) consists of chaotic small wavefronts that constantly change paths. BACKGROUND: Despite the significance of VF to cardiovascular mortality, little is known about the wavefronts that constitute VF in humans. METHODS: In 9 patients undergoing cardiac surgery, a single VF episode was induced by rapid pacing immediately after institution of cardiopulmonary bypass while recordings were made from 504 electrodes spaced 2 mm apart in a 20 cm(2) plaque held against the anterior left ventricle epicardium. A total of 26 segments of VF, each 2 s long, were analyzed. A computer algorithm identified individual wavefronts and classified them into groups that followed similar activation sequences. RESULTS: The mean activation rate was 5.8 +/- 1.8 (mean +/- SD) cycles/s. The wavefronts during each epoch were grouped into 9.4 +/- 7.1 different activation pathways, and 8.3 +/- 2.3 wavefronts followed each pathway. Individual wavefronts spread to activate an area of 5.1 +/- 3.0 cm(2) in the mapped region. The majority of the wavefronts propagated into the mapped region and/or propagated out of the mapped region into adjacent tissue, suggesting that the wavefronts were larger than 5.1 cm(2). Reentry was identified in only 16 of the 26 (62%) 2-s segments, always completed <2 cycles, and lasted for 9.5 +/- 6.6% of these 16 epochs, which is 5.8% of the total duration of all the segments analyzed. CONCLUSION: VF wavefronts on the human epicardium are usually large, repeatedly follow distinct pathways, and only occasionally reenter. If these results for the left ventricular epicardium are representative of those for the entire ventricular mass, they do not support the hypothesis that human VF consists of small, constantly changing wavefronts, but rather suggest that there is significant organization of human VF.

Action Potentials↗

Activation sequences following failed atrial defibrillation.

OBJECTIVES: The purposes of this study were to examine the first activations following atrial defibrillation shocks to help understand how and where atrial fibrillation (AF) relapsed following failed shocks and to assess the difference in postshock activation between failed and successful shocks. BACKGROUND: While many studies have investigated the mechanism of ventricular defibrillation, much less is known about the mechanisms of AF. METHODS: Sustained AF was induced electrically after pericardial infusion of methylcholine in 10 sheep. Biphasic subthreshold shocks were delivered to three configurations: right atrium to distal coronary sinus (RA-CS), sequential shocks with RA-CS as the first pathway followed by proximal CS to superior vena cava as the second pathway (Sequential), and right ventricle to superior vena cava plus can (V-triad). In eight sheep, global atrial mapping was performed with 504 electrodes spaced 3 to 4 mm apart. RESULTS: Earliest postshock activations mostly arose from the left atrium for V-triad but arose from either atrium for RA-CS and Sequential. Preshock AF cycle lengths were significantly shorter at the earliest activation sites than at seven of eight other sites globally distributed over both atria. In all type B successful episodes in which one or more rapid activations occurred after the shock and in 50 of the 72 failed episodes analyzed, activation fronts spread away from the earliest site in a focal pattern, and discrete nonfragmented activation complexes were present in the first derivatives of the electrograms. In the other 22 failed episodes, earliest activation fronts spread in a nonfocal pattern, and earliest postshock electrogram derivatives were fractionated. To better interpret the activation pattern in the fragmented regions, a 504 electrode plaque with 1.5-mm electrode spacing was placed on the right atrial appendage in two additional sheep. In 11 of 108 failed episodes, earliest postshock activation appeared inside the plaque and spread in a focal pattern with nonfragmented electrogram derivatives in 10 episodes and in a reentrant pattern with fragmented electrogram derivatives in the other. CONCLUSIONS: (1) The electrode configuration influenced the location of earliest postshock activation. (2) Earliest postshock activation occurred where the preshock AF cycle length was short. (3) Earliest activations following all type B successful and most failed episodes were not fragmented and spread in a focal pattern. (4) The region of earliest postshock activation in the failed episodes without a focal postshock activation pattern exhibited regions of fragmented electrogram derivatives that may represent conduction block and possibly reentry.

Animals↗

Effects of burst stimulation during ventricular fibrillation on cardiac function after defibrillation.

The purpose of defibrillation is to rapidly restore blood flow and tissue perfusion following ventricular fibrillation (VF) and shock delivery. We tested the hypotheses that 1) a series of 1-ms pulses of various amplitudes delivered before the defibrillation shock can improve hemodynamics following the shock, and 2) this hemodynamic improvement is due to stimulation of cardiac or thoracic sympathetic nerves. Ten anesthetized pigs received a burst of either 15 or 30 1-ms pulses (0.1-10 A in strength) during VF, after which defibrillation was performed. ECG, arterial blood pressure, and left ventricular (LV) pressure were recorded. Defibrillation shocks and burst pulses were delivered from a right ventricular coil electrode to superior vena cava coil and left chest wall electrodes. Sympathetic blockade was induced with 1 mg/kg timolol and trials were repeated. The first half of this protocol was repeated in two animals that were pretreated with reserpine. Heart rate (HR) after 1-, 2-, 5-, and 10-A pulses was significantly higher than after control shocks without preceding pulse therapy. Mean and peak LV pressure measurements increased 38 and 72%, respectively, following shocks preceded by 5- and 10-A pulses compared with shocks preceded by no burst pulses. Mean and peak arterial pressures increased 36 and 43%, respectively, following shocks preceded by 5- and 10-A pulses compared with shocks preceded by no burst pulses. After beta-blockade, HR, mean and peak arterial pressures, and mean LV pressure were not significantly different after pulses of any strength compared with control shocks. LV peak pressure following the 10-A pulses was significantly higher than with no burst pulses but was significantly lower than the response to the 10-A pulses delivered without beta-blockade. HR, mean and peak arterial pressures, and mean and peak LV pressure responses after 15 or 30 5- or 10-A pulses were similar to the responses to the same pulses after beta-blockade. We conclude that a burst of 15-30 1-ms pulses delivered during VF can increase HR, arterial pressure, and LV pressure following defibrillation. beta-Blockade or reserpine pretreatment prevents most of this postshock increase in HR, arterial pressure, and LV pressure.

Adrenergic Uptake Inhibitors↗

Comparison of six clinically used external defibrillators in swine.

BACKGROUND: External defibrillation has long been practiced with two types of monophasic waveforms, and now four biphasic waveforms are also widely available. Although waveforms and clinical dosing protocols differ among defibrillators, no studies have adequately compared performance of the monophasic or the biphasic waveforms. This is the first study to compare defibrillation efficacy among biphasic external defibrillators, and does so as part of a study comparing all commonly available waveforms using their respective manufacturer-provided and clinically used doses. METHODS AND RESULTS: Efficacy of six waveforms was tested in 852 short-duration ventricular fibrillation episodes in 14 swine. Protocol 1: 200-J monophasic damped sine (MDS) and monophasic truncated exponential (MTE) shocks were compared to 150-J biphasic shocks in six swine at the low-impedance of these animals. Protocol 2: Four commercially available biphasic defibrillators were compared using their respective manufacturer-recommended dose protocols in eight swine at low and simulated high-impedance. At low-impedance, all biphasic shocks achieved near-perfect success, while efficacy was significantly lower for MDS (67%) and MTE (30%) shocks. In protocol 2, first-shock success rates of the four biphasic defibrillators were uniformly high (97, 100, 100, and 94%) for low-impedance shocks, and decreased for high-impedance shocks (62, 92, 82, and 64%). There were statistically significant differences in efficacy among devices. CONCLUSIONS: Commonly used MDS and MTE waveforms provide markedly dissimilar efficacies. Despite impedance-compensation schemes in biphasic defibrillators, impedance has an impact on their efficacy. At high-impedance, modest efficacy differences exist among clinically available biphasic defibrillators, reflecting differences in both waveforms and manufacturer-provided doses.

Animals↗

Do clinically relevant transthoracic defibrillation energies cause myocardial damage and dysfunction?

Sufficiently strong defibrillation shocks will cause temporary or permanent damage to the heart. Weak defibrillation shocks do not cause any damage to the heart but also do not defibrillate. A relevant and practical question is what range of shock energies is most likely to defibrillate while not causing damage to the heart. This question is most difficult to answer in the pre-hospital defibrillation setting where the patients' size and shape vary, placement of the defibrillation patches vary, and the etiology of their arrhythmia varies. Unlike internal defibrillators, which are tested at implantation, efficacy of an external defibrillator is determined only once, when it is most needed. This review discusses shock damage and dysfunction caused by monophasic waveforms as well as biphasic waveforms. Evidence is presented suggesting that for perfused hearts, the threshold for damage is well above any shock size delivered clinically. For non-perfused hearts, both in humans and animals, evidence is presented that monophasic shocks of up to 5 J/kg do not cause any more cardiac damage/dysfunction than that associated with smaller shocks and that much of this damage is caused by the ischemic period itself rather than the shock. Although many patients can be defibrillated with 150 J (2.2 J/kg) biphasic shocks, some patients may require biphasic shocks up to 360 J (5 J/kg) to be defibrillated. Studies still need to be performed comparing the efficacy and damaging effects of 360 J biphasic shocks to 150 J biphasic shocks. Until those studies are completed, it seems reasonable to use the same 360 J (5 J/kg) energy limit for biphasic shocks as for monophasic shocks.

Animals↗

Identification of transmural necrosis along a linear catheter ablation lesion during atrial fibrillation and sinus rhythm.

BACKGROUND: Determining whether a linear catheter radio frequency (RF) ablation lesion is transmural may be difficult, especially during atrial fibrillation. We hypothesized that changes in pacing thresholds and electrogram amplitude during atrial fibrillation and sinus rhythm could be used to assess whether a radiofrequency ablation resulted in transmural necrosis. METHODS: A hexapolar, linear, RF ablation catheter was positioned between the caval veins in the right atrium of seven sheep. Pacing thresholds and electrogram amplitudes during atrial fibrillation and sinus rhythm were measured before and after the application of RF energy. Sites along the linear lesion were assessed histologically. RESULTS: The electrogram amplitude in atrial fibrillation decreased significantly more at transmural sites (unipolar recording: 33 +/- 11% transmural vs. 22 +/- 13% non-transmural, p < or = 0.01; bipolar recording: 62 +/- 9% transmural vs. 43 +/- 15% non-transmural, p < or = 0.01). The electrogram amplitude in sinus rhythm decreased significantly more at transmural sites (unipolar recording: 49 +/- 18% transmural vs. 15 +/- 20% non-transmural, p < 0.001; bipolar recording: 63 +/- 17% transmural vs. 42 +/- 19% non-transmural, p = 0.002). The pacing threshold increased significantly more at sites with transmural necrosis (unipolar: increased by 378 +/- 103% transmural vs. 207 +/- 93% non-transmural, p < 0.001; bipolar: 370 +/- 80% transmural vs. 259 +/- 60% non-transmural, p < 0.001). CONCLUSIONS: The amplitude of the atrial electrogram from an ablation catheter can be used to discriminate areas with transmural necrosis from those without transmural necrosis during either atrial fibrillation or sinus rhythm. Termination of atrial fibrillation may not be necessary to estimate the histologic characteristics of an ablation lesion.

Animals↗

Emission ratiometry for simultaneous calcium and action potential measurements with coloaded dyes in rabbit hearts: reduction of motion and drift.

INTRODUCTION: Optical measurements of the cardiac calcium transient (Ca) and transmembrane action potential (AP) may be performed simultaneously with emission ratiometry to lessen motion artifacts and photobleaching effects. We examined changes in emission spectrum in perfused rabbit hearts coloaded with Rh237 and a green-emitting Ca dye (Fluo-4 or Oregon Green BAPTA 1) to determine wavelength bands for emission ratiometry and to test whether ratiometry reduces motion artifacts and drift. METHODS AND RESULTS: A 488-nm laser illuminated hearts while a spectrofluorometer collected fluorescence from 489 to 838 nm at 1 kHz. Ratiometry with the Ca- and AP-insensitive emission band 663 to 685 nm (IS) as denominator and the Ca-sensitive band 510 to 532 nm as numerator lessened motion artifacts, which was quantified as a 1.4-fold increase in relative amplitude of the Ca (P < 0.05). Ratiometry with the AP-sensitive band 772 to 794 nm as denominator and the IS as numerator produced a 1.7-fold increase in relative amplitude of the AP (P < 0.05). The ratiometry decreased photobleaching-dependent drift by a factor of 0.6 (P < 0.05) for Ca and 0.45 (P < 0.05) for AP. CONCLUSION: Simultaneous Ca and AP emission ratiometry reduces motion artifacts and drift in hearts with coloaded dyes.

Action Potentials↗

Impact of myocardial ischemia and reperfusion on ventricular defibrillation patterns, energy requirements, and detection of recovery.

BACKGROUND: Shocks that have defibrillated spontaneous ventricular fibrillation (VF) during acute ischemia or reperfusion may seem to have failed if VF recurs before the ECG amplifier recovers after shock. This could explain why the defibrillation threshold (DFT) for spontaneous VF appears markedly higher than for electrically induced VF. METHODS AND RESULTS: The DFT for electrically induced VF (E-DFT) was determined in 15 pigs before ischemia, followed by left anterior ascending or left circumflex artery occlusion. VF was electrically induced 20 minutes after occlusion, followed 5 minutes later by reperfusion. Whether spontaneous or electrically induced, VF during occlusion or reperfusion was treated with up to 3 shocks at 1.5xE-DFT. If all 3 shocks failed, shock strength was increased. Thirty minutes after reperfusion, the other artery was occluded and the protocol was repeated. Defibrillation was considered successful if postshock sinus/idioventricular rhythm was present for > or = 30 seconds. VF recurring within 30 seconds after the shock was considered immediate or delayed if the first postshock activation complex in a rapidly restored ECG recording was VF or sinus/idioventricular rhythm, respectively. Defibrillation efficacy at 1.5xE-DFT was significantly higher for electrically induced ischemic VF (76%) than for spontaneous VF (31%). The incidence of delayed recurrence after electrically induced nonischemic (3%) or ischemic (20%) VF was significantly lower than after spontaneous VF (75%). Mean VF recurrence time after spontaneous VF was 4.6+/-5.3 seconds. CONCLUSIONS: Spontaneous VF can be halted by a shock but then quickly restart before a standard ECG amplifier has recovered from postshock saturation, making it appear that the shock failed.

Animals↗

Biphasic waveform external defibrillation thresholds for spontaneous ventricular fibrillation secondary to acute ischemia.

OBJECTIVES: The goal of this study was to determine if the defibrillation threshold (DFT) after spontaneous ventricular fibrillation (VF) secondary to acute ischemia differs from the DFT for electrically induced VF in the absence of ischemia in anesthetized, closed-chest dogs and pigs. BACKGROUND: The efficacy of external defibrillators has been tested mainly in animals and humans using E-VF, yet external defibrillators are often used in patients to halt S-VF. METHODS: Protocol 1: biphasic truncated exponential (BTE) waveform shocks were delivered through electrodes placed in an anterior-anterior (A-A) position (left and right lateral thorax) in nine dogs. After measuring the E-VF DFT, acute ischemia was induced with an angioplasty balloon in either the left anterior descending or left circumflex coronary artery, and the S-VF DFT was determined. Protocol 2: in a group of 12 pigs, the E-VF DFT and S-VF DFT were determined for electrodes in the A-A position and in the anterior-posterior position (A-P). Protocol 3: the E-VF DFT was determined in seven pigs. Then up to three shocks 1.5x the E-VF DFT were delivered to S-VF. If defibrillation did not occur, a step-up protocol was used until defibrillation occurred. RESULTS: Protocol 1: the DFT for E-VF was 65 +/- 28 J (mean +/- SD) compared with 226 +/- 97 J for S-VF, p < 0.05. Protocol 2: the DFT was 152 +/- 58 J for E-VF and 315 +/- 123 J for S-VF for A-A electrodes. The DFT was 100 +/- 43 J for E-VF and 206 +/- 114 J for S-VF for A-P electrodes. Protocol 3: 11/37 shocks of strength 1.5x E-VF DFT (182 +/- 40 J) stopped the arrhythmia. The episodes of S-VF not halted by these shocks required energy levels of up to 400 J for defibrillation. CONCLUSIONS: External defibrillation of S-VF induced by acute ischemia requires significantly more energy than VF induced by 60-Hz current in the absence of ischemia. A safety margin >1.5x the DFT for electrically induced VF may be necessary in BTE external defibrillators to defibrillate S-VF.

Animals↗

Endocardial wave front organization during ventricular fibrillation in humans.

OBJECTIVES: This study was designed to characterize the organization of ventricular fibrillation (VF) on the endocardium of humans. BACKGROUND: Most proposed mechanisms for the maintenance of VF postulate the propagation of a number of activation wave fronts that reenter to maintain the arrhythmia. We tested the hypothesis that, in patients undergoing internal cardioverter-defibrillator implantation, VF consists primarily of a few large wave fronts on the endocardium. METHODS: Electrograms were recorded from a 36-electrode catheter in the left ventricle of 16 patients during VF. Activation times were chosen for a 2-s epoch for each fibrillation episode, and a two-dimensional Kolmogorov-Smirnov test was performed to determine if activation occurred randomly along the catheter over that time interval. The maximum cross-correlation was found for all possible pairs of electrodes on the catheter, and these values were plotted relative to the distance between the two electrodes. An exponential curve was then fit to the data, and a length constant was determined. Activation times were grouped into wave fronts along the catheter, and the lengths of the wave fronts were estimated. RESULTS: The Kolmogorov-Smirnov test showed that activation was not random along the catheter in any of the patients studied. The correlation length determined was 9 +/- 2 cm. The number of wave fronts recorded by the catheter was 9.2 +/- 2.9 wave fronts/s. The length of the pathway of each wave front along the catheter was 6.5 +/- 4.5 cm. CONCLUSIONS: Ventricular fibrillation is well organized on the endocardial surface of humans, consisting primarily of a few large wave fronts on the order of 6 to 9 cm.

Adult↗