Griffith E Altmann

Publications and source records attributed to Griffith E Altmann.

2 recordsLinked to original sources

Optical performance of 3 intraocular lens designs in the presence of decentration.

PURPOSE: To study the theoretical optical performance of 3 intraocular lens (IOL) designs in the presence of IOL decentration. SETTING: Optics Center, Bausch & Lomb, Rochester, New York, USA. METHODS: A ray-tracing program was used to evaluate the effect of IOL decentration on the optical performance of 3 silicone IOLs (LI61U, Bausch & Lomb; Tecnis Z9000, Advanced Medical Optics; and a new aberration-free IOL [SofPort AO, Bausch & Lomb]) in an experimental model eye. The study was done using pupil diameters of 3.0 mm, 4.0 mm, and 5.0 mm and IOL decentrations of 0 mm, 0.25 mm, 0.50 mm, 0.75 mm, and 1.00 mm. The modulation transfer functions were computed and plotted. A Monte Carlo simulation analysis with 1000 trials with IOL decentration randomly varying for each pupil size was performed. RESULTS: Decentration of LI61U and Tecnis Z9000 IOLs led to asymmetrical higher-order aberrations that adversely affected the optical performance of the model eye; performance was not affected with the aberration-free IOL because it lacks inherent spherical aberration. Optical performance with the aberration-free IOL was better than with the LI61U IOL as the former has less spherical aberration and did not introduce other aberrations when decentered. Performance with the aberration-free IOL was better than with the Tecnis Z9000 IOL for 3.0 mm, 4.0 mm, and 5.0 mm pupils when decentration exceeded 0.15 mm, 0.30 mm, and 0.38 mm, respectively. Performance with the LI61U IOL was better than with the Tecnis Z9000 IOL for 3.0 mm, 4.0 mm, and 5.0 mm pupils when decentration exceeded 0.3 mm, 0.5 mm, and 0.5 mm, respectively. Monte Carlo simulations showed the expected postoperative results of the LI61U IOL and aberration-free IOL would be repeatable and predictable, whereas the outcomes with the Tecnis Z9000 IOL would vary widely. CONCLUSIONS: The optical performance of the model eye was not affected by decentration of an aspheric IOL designed to have no inherent spherical aberration. With decentration, the performance with the new IOL was better than with a conventional spherical IOL and an aspheric IOL designed to offset the spherical aberration of an average cornea.

Biocompatible Materials↗

Wavefront-customized intraocular lenses.

PURPOSE OF REVIEW: Recent advances in ocular wavefront measurement and in intraocular lens materials and manufacturing methods have brought cataract surgery to the brink of a period in which customized correction of higher-order aberrations with intraocular lenses may become standard practice. RECENT FINDINGS: Retinal image quality in pseudophakic eyes is limited by the wavefront aberrations of the cornea and the intraocular lens. The Tecnis Z9000 is the first commercially available intraocular lens designed to account for the wavefront aberrations of the cornea, specifically spherical aberration. Clinical findings with the Tecnis Z9000 intraocular lens show improved contrast sensitivity at low and mid spatial frequencies. However, if the lens decenters or tilts modestly, higher-order aberrations are created, and the lens may underperform relative to standard intraocular lenses. At present, one firm is developing an intraocular lens that may be modified in vivo with near ultraviolet energy. Such a technology offers tremendous potential for a fully customized intraocular lens. SUMMARY: Wavefront-customized intraocular lenses offer the promise of near perfect retinal image quality, such that only diffraction, chromatic aberration, retinal sampling and neural factors will limit vision in pseudophakic eyes.

Cornea↗