PubMed Health⌕ Search

Biomedical subjects

Gudrun Olthoff

Publications and source records attributed to Gudrun Olthoff.

2 recordsLinked to original sources

Parameters affecting primary stability of orthodontic mini-implants.

AIM: Treatment options in orthodontics have been expanded by skeletal anchorage via mini-implants over the last few years. Sufficient primary stability is imperative to minimize implant loss rate. The aim of this study was to quantitatively analyze the factors influencing primary stability: bone quality, implant-design, diameter, and depth of pilot drilling. MATERIAL AND METHODS: Thirty-six pelvic bone segments (ilium) of country pigs were dissected and embedded in resin. To determine the primary stability, we measured the insertion torque of five different mini-implant types (tomas-pin [Dentaurum, Ispringen, Germany] 08 and 10 mm, and Dual Top [Jeil Medical Corporation, Seoul, Korea] 1.6 x 8 and 10 mm plus 2 x 10 mm). Twenty-five or 30 implants were inserted into each pelvic bone segment following preparation of the implant sites using pilot drill diameters of 1.0, 1.1, 1.2 and 1.3 mm and pilot drill depths of 1, 2, 3, 6 and 10 mm. Five implants were inserted for reference purposes to establish comparability. Thicknesses of bone compacta were measured via micro-computer tomography. RESULTS: Insertion torques of orthodontic mini-implants and therefore primary stability varied greatly, depending on bone quality, implant-design, and preparation of implant site. Compared with the tomas-pin, the Dual Top screw showed significantly greater primary stability. Torque moments beyond 230 Nmm caused fractures of 9 Dual Top screws. CONCLUSION: Compacta thickness, implant design and implant site preparation have a strong impact on the primary stability of mini-implants for orthodontic anchorage. Depending on the insertion site and local bone quality, the clinician should choose an optimum combination of implant and pilot-drilling diameter and depth.

Animals↗

Effect of three different sealers on the sealing ability of both thermafil obturators and cold laterally compacted Gutta-Percha.

The purpose of this study was to assess the seal obtained in straight and curved root canals filled with either laterally compacted gutta-percha or Thermafil obturators. Each technique was used in combination with three different sealers (RSA RoekoSeal, AH Plus, AH 26). Thermafil obturators were also used without sealer, resulting in a total of 14 test groups of 16 teeth each. Sixty teeth served as positive or negative controls. Included in the study were 142 extracted teeth with straight and 142 with curved root canals. All canals were enlarged up to size 40. After obturation, all roots were placed in India ink for 48 h and rendered transparent to measure the maximum linear dye penetration. Canals filled with Thermafil obturators had significantly more extrusion of filling material than canals filled by lateral compaction (p < 0.01). Thermafil without sealer showed significantly greater dye penetration compared with all other groups both in straight and in curved canals (p < 0.05). As long as a sealer was used, the seal obturated with Thermafil was equivalent in terms of dye penetration to lateral compaction. There were no statistical differences in the mean apical dye penetration among the three sealers. The differences between the dye penetration in straight and in curved canals were insignificant for all groups (p > 0.05). Under the conditions of this study, Thermafil obturators achieved seals comparable to lateral compaction, as long as a sealer was used.

Analysis of Variance↗