Hydrodynamic evaluation of kangaroo aortic valve matrices for tissue valve engineering.

We evaluated the hydrodynamic performance of kangaroo aortic valve matrices (KMs) (19, 21, and 23 mm), as potential scaffolds in tissue valve engineering using a pulsatile left heart model at low and high cardiac outputs (COs) and heart rates (HRs) of 60 and 90 beats/min. Data were measured in two samples of each type, pooled in two CO levels (2.1 +/- 0.7 and 4.2 +/- 0.6 L/min; mean +/- standard errors on the mean), and analyzed using analysis of variance with CO level, HR, and valve type as fixed factors and compared to similar porcine matrices (PMs). Transvalvular pressure gradient (DeltaP) was a function of HR (P < 0.001) and CO (P < 0.001) but not of valve type (P = 0.39). DeltaP was consistently lower in KMs but not significantly different from PMs. The effective orifice area and performance index of kangaroo matrices was statistically larger for all sizes at both COs and HRs.

Animals↗

Stentless vs. stented aortic valve replacement: left ventricular mass regression.

The aim of this retrospective study was to evaluate the time-related regression of left ventricular hypertrophy after stentless vs. stented aortic valve replacement. From January 1992 to December 2002, 145 patients had a Toronto stentless porcine valve and 106 had a stented Carpentier-Edwards aortic valve replacement. Over a 10-year follow-up, survival was superior in the Toronto group vs. the Carpentier-Edwards group (84% vs. 74% at 4 years; 78% vs. 68% at 6 years; p < 0.001). A significant and constant reduction of peak and mean transvalvular gradients after valve replacement resulted in substantial regression of left ventricular mass index in both groups, which did not reach statistical significance. However, this phenomenon stopped at 3 years, and left ventricular mass index increased slowly after 5 years. Stentless and stented bioprostheses both showed good early and late clinical and hemodynamic outcomes, with the advantage of better midterm survival for stentless xenografts.

Adult↗

Aortic valve replacement with Toronto SPV in elderly patients: 10-year results.

A retrospective assessment of clinical and echocardiographic variables was performed in 145 patients who received a Toronto SPV aortic valve replacement. The majority (90%) of these elderly patients (mean age, 75.5 +/- 7.4 years) were preoperatively in New York Heart Association class III-IV. Operative mortality was 4.8%. Follow-up was complete up to 10 years and revealed few valve-related complications: thromboembolism (7), bleeding (4), and prosthesis dysfunction necessitating reoperation (3). Late mortality was cardiac-related in 11.7% and noncardiac-related in 17.2%. Actuarial survival was 83% at 5 years and 63% at 8 years. Echocardiography showed low transvalvular gradients (peak, 17.5 +/- 7.5 mm Hg; mean, 9.2 +/- 4.2 mm Hg) resulting in a significant reduction in left ventricular mass index during the first 3 years. Independent of the transprosthetic gradient, left ventricular mass index tended to increase again beyond the 5th year, which correlated positively with the presence of arterial hypertension in this older population. The Toronto SPV bioprosthesis offers an aortic valve substitute with excellent long-term hemodynamics, resulting in significant early left ventricular mass regression. Considering the limitations of this selected elderly population, the clinical outcome and survival up to 10 years are encouraging, with few observed valve-related events.

Aged↗

Predicting ATS Open Pivot heart valve performance with computational fluid dynamics.

BACKGROUND AND AIM OF THE STUDY: In-vitro studies on the ATS heart valve have indicated that valve opening is less in an expanding conduit than in a straight conduit. METHODS: Bileaflet valve behavior was studied using a new computational fluid-structure interaction model. A three-dimensional model of the ATS valve was studied in two geometries, simulating the valve in a geometry with sudden expansion downstream of the valve, and in a straight conduit. Mitral and aortic flow patterns were simulated. RESULTS: The ATS valve in the expanding geometry showed opening to a maximum angle of 77.5 degrees; this was confirmed in previous clinical and in-vitro studies. The mean and maximum transvalvular Doppler pressure gradients were 1.1 and 4.3 mmHg, respectively. The maximum shear stress calculated on the leaflet was 25 Pa. Maximum opening of the valve was achieved in the straight conduit; with mean and maximum pressure gradients of 2.1 and 4.6 mmHg, respectively. The maximum shear stress calculated on the leaflet was 35 Pa. CONCLUSION: The results of this numerical study confirmed that valve hemodynamics and leaflet motion were dependent on the geometrical conditions of the valve: the presence of a diverging flow influenced the maximum opening angle of the valve leaflets. This model could be used to predict pressure gradients, effective orifice area, performance index and shear stress loading of mechanical heart valves, and in future will serve as a major research tool to characterize the hemodynamics of existing and new mechanical heart valves.

Aortic Valve↗

Bovine glue (BioGlue) is catabolized by enzymatic reaction in the vascular dog model.

PURPOSE: The aim of the study is to explore the feasibility, patency, and histologic changes of a sutureless vascular anastomotic technique using biological glue as sole fixation method. DESCRIPTION: Eight mongrel dogs (+/-15 kg) underwent direct reanastomosis of their transsected iliac arteries. Both ends were placed on a 5-mm balloon and the anastomosis was secured with biological glue (BioGlue, Cryolife, Kennesaw, GA). No intravascular suture material was used. All survivors were angiographically controlled for patency after 6 weeks and 3 months. Then the animals were euthanized and tissues were obtained for histologic and pathologic examination by light and electron microscopy. EVALUATION: All procedures were successful except for 1 animal that died of uncontrollable bleeding at the anastomotic site. All first-time angiographically controlled grafts except three were patent. One animal showed manifest signs of fungal infection. Histology detected early granulocyte infiltration with an important enzymatic reaction adjacent to the surface of glue. Later on, the glue gradually regressed to disappear completely. Fibroblastic neointimal lining was noticed in most of the anastomoses, with some marked differences in the endothelium compared with normal. CONCLUSIONS: Good permeability (57%) was observed in this new sutureless anastomotic technique in the canine model. In contrast to previous reported studies we noticed a clear enzymatic breakdown of the glue before total disappearance. It is not yet known to what extend use of the bovine glue was responsible for this phenomenon.

Anastomosis, Surgical↗

The initial experience with the ATS Medical mechanical cardiac valve prosthesis.

BACKGROUND: From May 1994 through October 2000, a total of 1,146 patients underwent valve replacement with the ATS Medical mechanical cardiac valve prosthesis under a study protocol approved by international ethics committees (non-United States participants) or under a United States Food and Drug Administration-approved Investigational Device Exemption study. The study took place at 19 domestic and three international centers. METHODS: As required by the Food and Drug Administration's Heart Valve Guidance Document, only isolated implants were included in the study (double-valve implants were excluded), with operative and follow-up data collected from each center. RESULTS: Aortic valve replacement (AVR) was conducted in 801 patients (309 with coronary bypass) and mitral valve replacement (MVR) in 345 patients (78 with coronary bypass). Overall operative (< or = 30 days post implant) mortality was 2.1% (17 AVR = 2.1%, 7 MVR = 2.0%), 7 of which (AVR = 4, MVR = 3) were valve related. In 2,086 patient-years (1,459 AVR patient-years, 627 MVR patient-years) of follow-up, there were an additional 50 patient deaths of these, 18 were valve related, 9 due to anticoagulant related bleeding, 5 sudden/unexplained, and 1 each after stroke, thrombosis, prosthetic valve endocarditis, and thromboembolism. Late (>30 days post implant) valve-related complications included: transient and chronic thromboembolism (27 AVR (linearized rate 1.85%/patient-year) and 20 MVR (3.19%/patient-year), of which 11/47 (0.53%/patient-year) had chronic deficits, thrombosis (1 AVR = 0.07%/patient-year and 4 MVR = 0.64%/patient-year), paravalvular leak (10 AVR = 0.69%/patient-year and 8 MVR = 1.28%/patient-year), anticoagulant related hemorrhage (34 AVR = 2.33%/patient-year and 8 MVR = 1.28%/patient-year), prosthetic valve endocarditis (3 AVR = 0.21%/patient-year and 2 MVR = 0.32%/patient-year), and structural valve failure or dysfunction (0%). Echocardiographic gradients were proportional to valve size and did not significantly change over the follow-up period. CONCLUSIONS: This study documented the ATS Medical mechanical cardiac valve prosthesis to be a valuable addition to the surgeon's armamentarium in the treatment of cardiac valvular disease.

Aged↗

Lower anticoagulation for mechanical heart valves: experience with the ATS bileaflet valve.

BACKGROUND: The design of the bileaflet ATS (ATS Medical Inc., Minneapolis, USA) mechanical valve incorporates an open pivot at the hinge mechanism. Total washout of the blood at the pivot area was observed using 3-D computational fluid dynamics modelling. This phenomenon could make the valve less vulnerable to clot formation in patients without major thromboembolic risk factors. METHODS: From January 1993 to June 1999, 286 consecutive patients had the ATS valve inserted in the aortic position. Patients were divided into two groups. Group 1 comprised all patients in regular sinus rhythm with good left ventricular function (144 patients). Group 2 included patients in non-sinus rhythm and/or with large hypocontractile left ventricles (142 patients). The anticoagulation regime in group 1 was used to obtain an international normalised ratio (INR) between 1.5 and 2.5. This contrasts with our regular aim to maintain the INR strictly between 2.5 and 3.5 for all mechanical valves, as achieved in group 2. RESULTS: The follow-up period (99% completeness) ranged from 18 to 84 months. Survival (Kaplan-Meier) was 97 and 98% and 92 and 81% at 1 and 5 years in group 1 and group 2, respectively (P = 0.12). Log rank analysis failed to detect a statistical difference in thromboembolism or bleeding between both groups (P > 0.05). However, trends were in favour of group 1. Univariate analysis selected poor ventricular function and an 'erratic' INR value (P = 0.002) as risk factors for death. The sole independent risk factor for bleeding was the use of aspirin (P = 0.025). CONCLUSIONS: The excellent group 1 data and outcome encouraged us to continue our low intensive anticoagulation regime and perhaps should be regarded as a new concept for treatment of selected mechanical valve patients.

Journal Article↗

Lower-intensity anticoagulation for mechanical heart valves: a new concept with the ATS bileaflet aortic valve.

BACKGROUND AND AIM OF THE STUDY: The design of the bileaflet ATS mechanical valve incorporates an open pivot at the hinge mechanism. Total washout of blood at the pivot area seen using three-dimensional computational fluid dynamics modeling may make the valve less vulnerable for clot formation in patients without major thromboembolic risk factors. METHODS: Between January 1993 and June 1999, the ATS valve was implanted in the aortic position in 286 consecutive patients. Patients were allocated prospectively to two groups: group 1 comprised patients in regular sinus rhythm with good left ventricular (LV) function (n = 144); group 2 included patients in non-sinus rhythm and/or with large hypocontractile left ventricles (n = 142). The anticoagulation regime in group 1 was to achieve an INR of 1.5-2.5, rather than to maintain INR strictly at 2.5-3.5 for mechanical valves (as in group 2). RESULTS: Follow up was 99% complete and ranged from 50 to 120 months. Survival (Kaplan-Meier) was respectively 95% and 90% and 90% and 83% at 2 and 5 years in favor of group 1 (p = 0.0055). Multivariate analysis selected advanced age, poor LV function and 'erratic' INR as risk factors for death. Log rank analysis failed to detect any statistical difference in thromboembolism. Bleeding occurred more frequently in group 2 (p = 0.018); independent risk factors for bleeding were the presence of aspirin (p = 0.0164) and advanced age (p = 0.02). CONCLUSION: The excellent group 1 data and outcome encouraged continuation of the low-intensity anticoagulation regime, and should be regarded as a new concept for the treatment of mechanical valve patients.

Aged↗