PubMed Health⌕ Search

Biomedical subjects

Guido Moro

Publications and source records attributed to Guido Moro.

6 recordsLinked to original sources

Scar detection by contrast-enhanced magnetic resonance imaging in chronic coronary artery disease: a comparison with nuclear imaging and echocardiography.

We compared contrast-enhanced MRI (CeMRI) with the most widely used imaging techniques for myocardial infarct (MI) diagnosis, SPECT and Echo, in unselected patients with chronic coronary artery disease (CAD). Two blinded operators assessed scars on MRI, SPECT and Echo images using a 16-segments LV model. We studied 105 consecutive patients: 50 had Q-wave MI (Q-MI), 19 non Q-wave MI or rest angina (nonQ-MI/RA) and 36 effort angina (EA) history. CeMRI was positive, respectively, in 96%, 37%, and 6%, SPECT in 90%, 53%, and 44%, and Echo in 84%, 32%, and 28% of patients (within Q-MI: CeMRI vs. SPECT p < 0.03, vs. Echo p < 0.001; within EA CeMRI vs. SPECT and ECHO p < 0.001; all trends p < 0.001, pseudo r-square: 0.56-0.75 for CeMRI, 0.18-0.28 for SPECT and 0.23-0.37 for Echo). CeMRI and SPECT agreed in 83 patients (79%); negative SPECT with 1 +/- 0 segments subendocardial delayed enhancement (DE) was found in 4 (4%); negative CeMRI with 4 +/- 3 segments perfusion defects in 18 (17%), 16 of whom were obese or showed LBB or sub-occlusion of related coronary. CeMRI and Echo agreed in 78 patients (75%); negative Echo with 2 +/- 1 segments subendocardial DE was found in 13 (12%) and negative CeMRI with 11 +/- 7 segments kinetic abnormalities in 14 (13%), in 10 confirmed by Cine-MRI. In Q-MI, CeMRI detects DE more frequently than perfusion defects and, especially, kinetic abnormalities are found by SPECT and Echo, respectively. CeMRI identifies small areas of DE also in some patients with nonQ-MI or RA but usually not in patients with EA. This biologically plausible decreasing trend is shown by CeMRI more clearly than by SPECT and Echo. Disagreement between CeMRI and SPECT or Echo may be reduced, but perhaps not fully eluded, performing dobutamine Echo and SPECT after maximal epicardial coronary dilatation.

Aged↗

Contrast-enhanced magnetic resonance imaging assessment of scar size in patients with chronic myocardial infarction.

BACKGROUND: In the assessment of myocardial infarction (MI) mass, contrast-enhanced magnetic resonance imaging (CE-MRI) is comparable to single-photon emission computed tomography (SPECT). The aim of the present study was to determine whether the MI area, as assessed at CE-MRI and SPECT, is comparable to mass evaluation. We also compared CE-MRI and SPECT estimates of the MI area with functional evaluations made at echocardiography and kinetic MRI (cine-MRI). METHODS: We used a 1.0 Tesla MRI scanner and an inversion-recovery turboFLASH sequence, a tomographic gamma-camera and second-harmonic ultrasound systems. Two blinded operators assessed the extent of scarring, expressed as a percentage of the whole left ventricle (LV), using a 16-segment model. We studied 55 consecutive patients with a clinically stable healed MI (50 Q wave, 5 non-Q wave). RESULTS: The scar mass was 19+/-23% of the LV at CE-MRI and 21+/-25% at SPECT; the scar area was 29+/-23% of the LV at CE-MRI, 41+/-28% at SPECT, 29+/-31% at cine-MRI, and 32+/-29% at echocardiography. The Bland-Altman bias between CE-MRI and SPECT mass estimations was -2% of the LV with a+/-23% limit of agreement (LOA), while the bias between the area assessments was -12% with a+/-42% LOA. Bias between CE-MRI and functional evaluation by cine-MRI and echocardiography was 0% with a+/-39% LOA and -3% with a+/-36% LOA respectively. Comparing SPECT with cine-MRI and echocardiography the bias was 12% with a+/-52% LOA and 9% with a+/-56% LOA respectively. CONCLUSIONS: CE-MRI has proved to be comparable to SPECT in the assessment of the healed MI mass. Conversely, a high systematic error (high bias and LOA) renders CE-MRI and SPECT assessments of the MI area incomparable. Similarly (high bias and/or LOA) CE-MRI and SPECT estimations of the MI area cannot be compared with functional evaluation by echocardiography or cine-MRI.

Aged↗

Primary dietary prevention of food allergy.

OBJECTIVE: To present research and clinical evidence on the use of primary dietary prevention in food allergy management. DATA SOURCES: We conducted MEDLINE searches for pertinent articles published between January 1986 and October 2001 with use of the following keywords or phrases: prevention and diet and allergy, food allergy and prevention, and dietary prevention and food allergy or allergens. Also included are information and commentary reflecting the authors' cumulative clinical experience in an allergy unit of a city hospital. RESULTS: We define as "proactive" those strategies centered on "success factors," such as the early postnatal environment, prolonged breast-feeding, and use of formula and probiotic supplementation, in contrast to earlier "prohibitionist" approaches to prevention of food allergy. These two approaches are not antagonistic and may even be synergistic. We introduce this distinction in light of epidemiologic evidence and out of concern about compliance and the quality of life for patients. CONCLUSIONS: Inasmuch as nutritional and immune maturation are implicated, the prohibitionist measures that are most effective in primary prevention of food allergy are exclusive breast-feeding for at least 6 months (for lifelong immunity and other benefits), delayed (after the sixth month) introduction of solid foods, and on-indication use of "hypoallergenic" formulas. Whether proactive strategies can be contemplated remains a debatable issue. Evidence for and against the scientific use of probiotics as well as microbiologic, epidemiologic, and clinical data are discussed. Review of published epidemiologic studies and randomized clinical trials is essential before planning dietary intervention or prevention.

Allergens↗

Whey predominant, whey modified infant formula with protein/energy ratio of 1.8 g/100 kcal: adequate and safe for term infants from birth to four months.

BACKGROUND: Protein quality of breast milk is superior to that of formula proteins. To ensure that the protein intake is sufficient, starter formulas with conventional protein composition provide a protein/energy ratio of 2.2-2.5 g per 100 kcal to infants, which is much higher than that supplied with breast milk. Several studies have shown that formula-fed infants have higher plasma or serum urea concentrations than breast-fed infants do. We tested if feeding formulas with improved protein quality and a protein content corresponding to the minimum level that is consistent with international recommendations (1.8 g/100 kcal) allows patients to achieve normal growth and plasma urea concentrations. METHODS: Healthy term infants were enrolled into the study and were either breast-fed or randomly assigned to three formula-fed groups. Formula-fed infants received either a standard formula with a protein/energy ratio of 2.2 g/100 kcal, whereas the two other groups received formulas with a protein/energy ratio of 1.8g/100 kcal differing mainly by their source of protein. Subjects received breast milk or these formulas ad libitum as the sole source of energy from birth to four months of age in a controlled blind design (except for the breast-fed group). Anthropometric measurements (body weight and length) were obtained at birth, at 30, 60, 90, and 120 days. Energy and protein intakes were calculated from three-day dietary records. Blood was collected for biochemical measurements at 30, 60, and 120 days. RESULTS: No differences were found between the four feeding groups for weight- and length-gains or for body mass indices (BMI). No differences in energy intakes between the formula-fed groups could be found, whereas protein intakes were less in infants fed the 1.8 g/100 kcal formulas. Plasma urea levels of the infants fed the 1.8 g/100 kcal formulas were closer to those found in the breast-fed infants. CONCLUSION: Improvement of the amino acid profile permits a whey predominant starter formula with 1.8 g protein per 100 kcal to meet the needs of normal term infants during the first four months of life.

Amino Acids↗

Retrorectal tumours: a case report.

The authors describe a case of retrorectal tumour in a 48-year-old female. Retrorectal tumours are rare, and their diagnosis is notoriously difficult and late. In this case the first-step diagnosis was made on the basis of clinical findings and radiological investigations such as abdominal ultrasonography. The second step included pelvic CT scans and MR imaging which yielded more precise anatomical details and information for the best surgical approach. We opted for a posterior approach with complete, easy removal of the tumour mass which, after pathological examination, turned out to be an epidermoid cyst. The postoperative course was uneventful and, one year after operation, the patient complains only of mild, irregular perineal pain with completely negative radiological investigations (US and CT scan).

Epidermal Cyst↗