PubMed Health⌕ Search

Biomedical subjects

Guilherme Cardoso

Publications and source records attributed to Guilherme Cardoso.

2 recordsLinked to original sources

A successive parameter estimation algorithm for chirplet signal decomposition.

In ultrasonic imaging systems, the patterns of detected echoes correspond to the shape, size, and orientation of the reflectors and the physical properties of the propagation path. However, these echoes often are overlapped due to closely spaced reflectors and/or microstructure scattering. The decomposition of these echoes is a major and challenging problem. Therefore, signal modeling and parameter estimation of the nonstationary ultrasonic echoes is critical for image analysis, target detection, and object recognition. In this paper, a successive parameter estimation algorithm based on the chirplet transform is presented. The chirplet transform is used not only as a means for time-frequency representation, but also to estimate the echo parameters, including the amplitude, time-of-arrival, center frequency, bandwidth, phase, and chirp rate. Furthermore, noise performance analysis using the Cramer Rao lower bounds demonstrates that the parameter estimator based on the chirplet transform is a minimum variance and unbiased estimator for signal-to-noise ratio (SNR) as low as 2.5 dB. To demonstrate the superior time-frequency and parameter estimation performance of the chirplet decomposition, ultrasonic flaw echoes embedded in grain scattering, and multiple interfering chirplets emitted by a large, brown bat have been analyzed. It has been shown that the chirplet signal decomposition algorithm performs robustly, yields accurate echo estimation, and results in SNR enhancements. Numerical and analytical results show that the algorithm is efficient and successful in high-fidelity signal representation.

Algorithms↗

Ultrasonic data compression via parameter estimation.

Ultrasonic imaging in medical and industrial applications often requires a large amount of data collection. Consequently, it is desirable to use data compression techniques to reduce data and to facilitate the analysis and remote access of ultrasonic information. The precise data representation is paramount to the accurate analysis of the shape, size, and orientation of ultrasonic reflectors, as well as to the determination of the properties of the propagation path. In this study, a successive parameter estimation algorithm based on a modified version of the continuous wavelet transform (CWT) to compress and denoise ultrasonic signals is presented. It has been shown analytically that the CWT (i.e., time x frequency representation) yields an exact solution for the time-of-arrival and a biased solution for the center frequency. Consequently, a modified CWT (MCWT) based on the Gabor-Helstrom transform is introduced as a means to exactly estimate both time-of-arrival and center frequency of ultrasonic echoes. Furthermore, the MCWT also has been used to generate a phase x bandwidth representation of the ultrasonic echo. This representation allows the exact estimation of the phase and the bandwidth. The performance of this algorithm for data compression and signal analysis is studied using simulated and experimental ultrasonic signals. The successive parameter estimation algorithm achieves a data compression ratio of (1-5N/J), where J is the number of samples and N is the number of echoes in the signal. For a signal with 10 echoes and 2048 samples, a compression ratio of 96% is achieved with a signal-to-noise ratio (SNR) improvement above 20 dB. Furthermore, this algorithm performs robustly, yields accurate echo estimation, and results in SNR enhancements ranging from 10 to 60 dB for composite signals having SNR as low as -10 dB.

Algorithms↗