PubMed Health⌕ Search

Biomedical subjects

Gunter Eder

Publications and source records attributed to Gunter Eder.

4 recordsLinked to original sources

Genomewide linkage analysis identifies novel genetic Loci for lung function in mice.

RATIONALE: Pulmonary function, including lung volumes and compliance, may be genetically determined, but few genetic polymorphisms have been identified that control these traits. We used an experimental approach and performed the first whole genome scan for pulmonary function in mice. OBJECTIVES AND METHODS: To identify novel chromosomal regions contributing to lung function, quantitative trait locus linkage analysis was applied in N(2) backcross and F(2) intercross mice derived from two inbred strains-C3H/HeJ and JF1/Msf-with extremely divergent phenotypes. MAIN RESULTS: Significant linkages to total lung capacity with LOD (logarithm of the odds) scores up to 6.0 were detected on chromosomes 15 and 17, to dead space volume and lung compliance on chromosomes 5 and 15 (LOD scores higher than 4.0), to lung compliance also on chromosome 19 (LOD score of 5.8), and to diffusing capacity on chromosomes 15 and 17 (LOD scores up to 5.0). The region of interest on chromosome 17 near D17Mit133 contains a syntenic region to human chromosome 6q27, which was recently identified to be linked to lung function in humans. The identified intervals harbor valuable candidate genes, such as the relaxin1 and transforming growth factor beta receptor 3 gene, which revealed missense polymorphisms between the parental strains. CONCLUSION: The study provides evidence for linkage of different measures of lung function on murine chromosomes 5, 15, 17, and 19 and suggests novel candidate genes that may also affect the expression of human pulmonary function.

Animals↗

Labeled carbon dioxide (C18O2): an indicator gas for phase II in expirograms.

Carbon dioxide labeled with 18O (C18O2) was used as a tracer gas for single-breath measurements in six anesthetized, mechanically ventilated beagle dogs. C18O2 is taken up quasi-instantaneously in the gas-exchanging region of the lungs but much less so in the conducting airways. Its use allows a clear separation of phase II in an expirogram even from diseased individuals and excludes the influence of alveolar concentration differences. Phase II of a C18O2 expirogram mathematically corresponds to the cumulative distribution of bronchial pathways to be traversed completely in the course of exhalation. The derivative of this cumulative distribution with respect to respired volume was submitted to a power moment analysis to characterize volumetric mean (position), standard deviation (broadness), and skewness (asymmetry) of phase II. Position is an estimate of dead space volume, whereas broadness and skewness are measures of the range and asymmetry of functional airway pathway lengths. The effects of changing ventilatory patterns and of changes in airway size (via carbachol-induced bronchoconstriction) were studied. Increasing inspiratory or expiratory flow rates or tidal volume had only minor influence on position and shape of phase II. With the introduction of a postinspiratory breath hold, phase II was continually shifted toward the airway opening (maximum 45% at 16 s) and became steeper by up to 16%, whereas skewness showed a biphasic response with a moderate decrease at short breath holding and a significant increase at longer breath holds. Stepwise bronchoconstriction decreased position up to 45 +/- 2% and broadness of phase II up to 43 +/- 4%, whereas skewness was increased up to twofold at high-carbachol concentrations. Under all circumstances, position of phase II by power moment analysis and dead space volume by the Fowler technique agreed closely in our healthy dogs. Overall, power moment analysis provides a more comprehensive view on phase II of single-breath expirograms than conventional dead space volume determinations and may be useful for respiratory physiology studies as well as for the study of diseased lungs.

Airway Resistance↗

Lung volume is a determinant of aerosol bolus dispersion.

The technique of inhaling a small volume element labeled with particles ("aerosol bolus") can be used to assess convective gas mixing in the lung. While a bolus undergoes mixing in the lung, particles are dispersed in an increasing volume of the respired air. However, determining factors of bolus dispersion are not yet completely understood. The present study tested the hypothesis that bolus dispersion is related, among others, to the total volume in which the bolus is allowed to mix--i.e., to the individual lung size. Bolus dispersion was measured in 32 anesthetized, mechanically ventilated dogs with total lung capacities (TLCs) of 1.1-2.5 L. Six-milliliter aerosol boluses were introduced at various preselected time-points during inspiration to probe different volumetric lung depths. Dispersion (SD) was determined by moment analysis of particle concentrations in the expired air. We found linear correlations between SD at a given lung depth and the individual end-inspiratory lung volume (V(L)). The relationship was tightest for boluses inhaled deepest into the lungs: SD(40) = 0.068 V(L) - 1.77, r(2) = 0.59. Normalizing SD to V(L) abolished this dependency and resulted in a considerable reduction of inter-individual variability as compared to the uncorrected measurements. These data indicate that lung size influences measurements of bolus dispersion. It therefore appears reasonable to apply a normalization procedure before interpreting the data. Apart from a reduction in measurement variability, this should help to separate the effects on bolus dispersion of altered lung volumes and altered mixing processes in diseased lungs.

Administration, Inhalation↗

Inbred strain variation in lung function.

The purpose of the present study was to determine the strain-specific phenotype variance of lung function parameters among common inbred laboratory mouse strains. In accordance with the "Mouse Phenome Project" run by The Jackson Laboratory (http://www.jax.org/phenome), lung volumes, lung mechanics, and diffusing capacity of 16 males and 16 females of the strains C3H/HeJ, BALB/cByJ, C57B1/6J, A/J, FVB/J, 129SV/ImJ, and SWR/J were determined in a standardized manner. The defined respiratory maneuvers for lung function testing were performed with a custom-made, computer-controlled servo-ventilator in anesthetized animals. Sex differences within the strains were found in most (83%) of the absolute lung function parameters. Usually, normalization to body or lung size completely compensates for the observed gender differences. There was great diversity between strains for all of the lung function parameters studied; for example, the total lung capacity as well as the pulmonary diffusing capacity for carbon monoxide varied by 50% and the static lung compliance by a factor of almost two among the strains. Little, but statistically significant variability was detectable for the dead space volume and the respiratory system resistance. There was no clear-cut evidence for any strain exhibiting either the smallest or the largest values for all parameters studied, suggesting that there were no simple allometric relationships of lung size between the strains. Well-established genealogical relationships among strains were not constantly reflected in phenotype similarities of pulmonary function. Therefore, these data strongly support heritable genetic traits for pulmonary function. Moreover, it constitutes a basis for further genetic lung function-related studies.

Animals↗