PubMed Health⌕ Search

Biomedical subjects

Guor-Rong Her

Publications and source records attributed to Guor-Rong Her.

13 recordsLinked to original sources

Rapid protein identification using a disposable on-line clean-up/concentrating device and electrospray ionization mass spectrometry.

A simple, low-cost, expedient method has been developed for identification of proteins isolated from two-dimensional (2D) gels. The method described uses a disposable on-line clean-up device, a syringe infusion pump and electrospray ionization mass spectrometry (ESI-MS). The on-line clean-up and concentrating device is a tapered capillary column filled with 1.5 cm of 5 microm C18 particles. The short column was easily prepared and was connected directly to the ESI source through a low-flow ESI sprayer. Peptides resulting from enzymatic digestion of proteins were eluted from the short column isocratically using a syringe infusion pump and analyzed by ESI-MS. This simple set-up was found useful in the analysis of proteins isolated from 2D gels. Compared to the more conventional micro-liquid chromatography/tandem mass spectrometry (microLC/MS/MS), this method can identify proteins rapidly without the need for an HPLC pump and removes the problem of cross-contamination caused by system carryover. These advantages make the method described competitive with conventional LC/MS even though the latter method gives slightly expanded sequence coverage.

Amino Acid Sequence↗

Linkage and branch determination of N-linked oligosaccharides using sequential degradation/closed-ring chromophore labeling/negative ion trap mass spectrometry.

A method based on sequential degradation, p-aminobenzoic ethyl ester (ABEE) closed-ring labeling, and negative ion electrospray ionization tandem mass spectrometry is presented for the study of linkage and branch determination for N-linked oligosaccharides. Closed-ring labeling provides greater linkage information than the more popular open-ring reductive amination approach. In addition, after high-performance liquid chromatography (HPLC) separation, closed-ring labeling allows for regeneration of the underivatized oligosaccharide, a requirement for alkaline sequential degradation. The analytical scheme presented here uses HPLC separation of closed-ring labeled oligosaccharides to resolve the mixture into individual forms that undergo subsequent structural analysis by negative ion tandem mass spectrometry. To facilitate complete structural analysis, particularly for larger sugars, the closed-ring labels are removed and the sugars are sequentially degraded by controlled alkaline hydrolysis. It is noteworthy that for sugars containing sialic acid moieties, a protecting group must be used to stabilize sialic acid groups during sequential alkaline degradation. This described approach was applied to two high mannose oligosaccharides M5G2, M6G2 cleaved from the ribonuclease B and a complex oligosaccharide A2 cleaved from transferrin.

4-Aminobenzoic Acid↗

Development of a multiplexed interface for capillary electrophoresis-electrospray ion trap mass spectrometry.

A four-channel multiplexed electrospray capillary electrophoresis interface has been developed. This new interface permits up to four capillary electrophoresis columns to be sampled sequentially by means of a stepper motor and a notched rotating plate assembly, which at any instant occludes all but a single sprayer. In this design, four sheath liquid electrospray probes are oriented in a circular array situated 90 degrees relative to one another. The rotating metal disk, which contains a one-quarter notch, is mounted to the stepper motor assembly and is located between the sprayers and the entrance aperture of an ion trap mass spectrometer. By using the data acquisition signal from the ion trap mass spectrometer, the scan event is synchronized with the rotation of the metal disk. With this device, four discrete sample streams can be simultaneously analyzed, resulting in a 4-fold increase in analytical throughput.

Electrophoresis, Capillary↗

Sheathless capillary electrophoresis-mass spectrometry using a pulsed electrospray ionization source.

A sheathless interface has been developed for coupling CE with electrospray IT mass spectrometer. This interface utilized a pulsed ESI source. The use of a pulsed electrospray source allows the use of a sprayer with larger orifice, and thus alleviates the problem of column clogging during conductive coating and CE analysis. A pulsed ESI source operated at 20 Hz and 20% duty cycle was found to produce the optimal signals. For better signals, the maximum ion injection time in the IT mass spectrometer has to be set to a value close to the actual spraying time (10 ms). Using a sprayer with 50 microm od, more stable and enhanced signals were obtained in comparison with continuous CE-ESI-MS under the same flow rate (150 nL/min). The utility of this design is demonstrated with the analysis of synthetic drugs by CE-MS.

Electrophoresis, Capillary↗

Analysis of triazines by capillary electrochromatography/electrospray ionization-mass spectrometry using a low-flow sheath liquid interface.

CEC-MS has been used for the analysis of eight-triazine herbicides. It showed significantly better S/N ratio than reversed EOF CE-MS and MEKC-MS, due to the lack of a surfactant in the separation buffer. By optimizing the pH, the organic content of the running buffer, and the separation potential, optimal separation was achieved within 18 min using a running buffer of pH 7.0, containing 70% v/v ACN, and an applied voltage of 17 kV. Gradient CEC showed superior separation when compared with isocratic elution. The combination of a tapered CEC column and a low-flow interface confers several advantages including better sensitivity, low dead volume, and independent control of the conditions used for CEC separation and ESI analysis.

Capillary Electrochromatography↗

Design and performance of a low-flow capillary electrophoresis-electrospray-mass spectrometry interface using an emitter with dual beveled edge.

A low-flow electrophoresis-mass spectrometry (CE-MS) interface has been developed for interfacing capillary zone electrophoresis (CZE) with electrospray- ionization-mass spectrometry (ESI-MS). The interface consists of two parallel capillary columns (a separation column and a makeup column), and an emitter with a dual beveled edge. While maintaining a relatively low optimum flow rate, the dual-beveled-edge ESI emitter allows the use of a tip with larger orifice. Therefore, this interface is less prone to column blocking in comparison with a flat tip. Primarily attributed to low sample dilution and smaller initial droplet, the interface showed better sensitivity than a conventional sheath liquid interface. Furthermore, the interface was found to be more resistant to the presence of nonvolatile salts. By using 40 mM borate and 20 mM alpha-cyclodextrin (alpha-CD) as the running buffer, four major forms of gangliosides were detected by CE-MS.

Electrophoresis, Capillary↗

A low-makeup beveled tip capillary electrophoresis /electrospray ionization mass spectrometry interface for micellar electrokinetic chromatography and nonvolatile buffer capillary electrophoresis.

A robust interface has been developed for interfacing micellar electrokinetic chromatography (MEKC) and nonvolatile buffer capillary electrophoresis (CE) to electrospray ionization mass spectrometry (ESI-MS). The interface consists of two parallel capillaries for separation (50 microm i.d. x 155 microm o.d.) and makeup (50 microm i.d. x 155 microm o.d.) housed within a larger capillary (530 microm i.d. x 690 microm o.d.). The capillaries terminate in a single tapered tip having a beveled edge. The use of a tapered beveled edge results in a greater tip orifice diameter (75 microm) than in a previous design from our laboratory (25 microm) that used a flat tip. While maintaining a similar optimum flow rate and consequently similar sample dilution, a 75-microm beveled emitter is more rugged than a 25-microm flat tip. Furthermore, the incorporation of a sheath liquid capillary allows the compositions of the final spray solution to be controlled. The application of this novel CE/ESI-MS interface was demonstrated for MEKC using mixtures of triazines (positive ion mode) and phenols (negative ion mode). The ability to perform CE/ESI-MS using a nonvolatile buffer was demonstrated by the analysis of gangliosides with a buffer consisting of 40 mM borate and 20 mM alpha-cyclodextrin.

Journal Article↗

A beveled tip sheath liquid interface for capillary electrophoresis-electrospray ionization-mass spectrometry.

A simple and durable sheath liquid interface for capillary zone electrophoresis-electrospray ionization-mass spectrometry (CZE-ESI-MS) has been developed. This interface utilized a beveled tip emitter and was found to be more sensitive than the conventional sheath liquid interface. The use of a beveled tip reduces the optimal flow rate and therefore decreases sample dilution. The interface utilized a 380 microm inner diameter and 400 microm outer diameter beveled tapered tip. Because of the large inner diameter and outer diameter of the tip, the interface is robust and can be easily implemented. The performance of this interface for CZE-ESI-MS and micelle electrokinetic capillary electrophoresis-electrospray-mass spectrometry, as demonstrated by the analysis of synthetic drugs and triazine mixtures, was significantly better than results obtained using a conventional sheath liquid interface.

Electrophoresis, Capillary↗

A low-flow ce/electrospray ionization MS interface for capillary zone electrophoresis, large-volume sample stacking, and micellar electrokinetic chromatography.

A simple and versatile low-flow interface has been developed for interfacing capillary electrophoresis (CE) with electrospray ionization (ESI) mass spectrometry. This low-flow interface showed better sensitivity than a conventional sheath liquid interface, primarily attributed to a low dilution factor and a reduction in the sprayer orifice size. The interface was also found to be more tolerant to the presence of nonvolatile salts. Because of tolerance to the surfactant SDS, this interface can be used to couple micellar electrokinetic chromatography (MEKC) with ESI-MS. The performance of the interface in an MEKC-MS application, as demonstrated in the analysis of triazines, was significantly better than that obtained with a conventional sheath liquid interface. Moreover, this interface can be easily used for large-volume sample-stacking (LVSS) applications. Using a series of phenols as a test case, an approximate 500-fold enrichment was achieved by LVSS in conjunction with the low-flow CE/MS interface described.

Journal Article↗

A simple method for fabrication of silver-coated sheathless electrospray emitters.

A simple and time-saving procedure is proposed for preparing a silver-coated fused-silica capillary tip. The tapered capillary tip was coated with silver using an acrylic-based silver conductive pen. The fabrication of a silver-coated fused-silica capillary tip takes less than 5 minutes. The silver-coated fused-silica capillary tip is rugged and durable for sheathless capillary electrophoresis/electrospray mass spectrometry and also for microspray applications.

Animals↗

Self-complementarity of oligo-2-aminopyridines: a new class of hydrogen-bonded ladders.

A new class of hydrogen-bonded ladders based on hydrogen-bonded dimerization of oligo-alpha-aminopryidines has been demonstrated. Jorgensen's model can be successfully applied to this hydrogen-bonding system in nonpolar solvents. The results show the competitive enthalpy/entropy compensation relationship upon dimerization. Although increasing the number of hydrogen-bonding interactions would enhance the hydrogen-bonding stabilization enthalpy, this stabilization enthalpy per unit would be partially sacrificed to compensate for the entropy loss due to dimerization. These results clearly support the importance of preorganization in designing hydrogen-bonding guest-host molecules.

Journal Article↗

Analysis of N-glycosylation of phospholipase A2 from venom of individual bees by microbore high-performance liquid chromatography-electrospray mass spectrometry using an ion trap mass spectrometer.

The N-linked oligosaccharides were released from the phospholipase A2 (PLA) with glycopeptidases and reductively aminated with the chromophore, p-aminobenzoic acid ethyl ester (ABEE). The ABEE-labeled oligosaccharides were separated by microbore high-performance liquid chromatography (micro-HPLC) using a reversed-phase column and analyzed by electrospray mass spectrometry. Differentiation between alpha-1,3 and alpha-1,6 core-fucosylated glycans was achieved by comparison the glycans released by glycopeptidases peptide-N-glycanase A (PNase A) and peptide-N-glycanase F (PNase F). All N-linked oligosaccharides except 3B and 3C could be identified in this approach. The analysis of PLA oligosaccharides from the venom of individual bees indicated that glycosylation patterns between the younger and the older bees were similar.

Animals↗