PubMed Health⌕ Search

Biomedical subjects

Gustav J Strijkers

Publications and source records attributed to Gustav J Strijkers.

15 recordsLinked to original sources

Early in vivo assessment of angiostatic therapy efficacy by molecular MRI.

Noninvasive diagnostic imaging methods to establish the efficacy of angiostatic therapies are becoming increasingly important with the first Food and Drug Administration approvals of such agents. Magnetic resonance molecular imaging is an imaging technique that allows the visualization of pathological processes in vivo with a better spatial resolution as compared with nuclear methods, such as photon emission tomography and single photon emission computed tomography. In this study, we used alpha(v)beta3 targeted bimodal liposomes to quantitate angiogenesis in a tumor mouse model with magnetic resonance imaging (MRI) and to evaluate the therapeutic efficacy of the angiogenesis inhibitors anginex and endostatin. The MRI findings were validated with fluorescence microscopy and showed a very good correlation with the microvessel density. In conclusion, this study provides evidence that molecular MRI can be used to noninvasively measure the efficacy of angiogenesis inhibitors during the course of therapy.

Angiogenesis Inhibitors↗

Comparison between prospective and retrospective triggering for mouse cardiac MRI.

High-resolution magnetic resonance imaging (MRI) has evolved into one of the major non-invasive tools to study the healthy and diseased mouse heart. This study presents a Cartesian CINE MRI protocol based on a fast low-angle shot sequence with a navigator echo to generate cardiac triggering and respiratory gating signals retrospectively, making the use of ECG leads and respiratory motion sensors obsolete. MRI of the in vivo mouse heart using this sequence resulted in CINE images with no detectable cardiac and respiratory motion artefacts. The retrospective method allows for steady-state imaging of the mouse heart, which is essential for quantitative contrast-enhanced MRI studies. A comparison was made between prospective and retrospective methods in terms of the signal-to-noise ratio and the contrast-to-noise ratio between blood and myocardial wall, as well as global cardiac functional indices: end-diastolic volume, end-systolic volume, stroke volume and ejection fraction. The retrospective method resulted in almost constant left-ventricle wall signal intensity throughout the cardiac cycle, at the expense of a decrease in the signal-to-noise ratio and the contrast-to-noise ratio between blood and myocardial wall as compared with the prospective method. Prospective and retrospective sequences yielded comparable global cardiac functional indices. The largest mean relative difference found was 8% for the end-systolic volume.

Algorithms↗

Liposome-enhanced MRI of neointimal lesions in the ApoE-KO mouse.

Conventional high-resolution MRI is capable of detecting lipid-rich atherosclerotic plaques in both human atherosclerosis and animal models of atherosclerosis. In this study we induced neointimal lesions in ApoE-KO mice by placing a constrictive collar around the right carotid artery. The model was imaged with conventional multispectral MRI, and the thickened wall could not be distinguished from surrounding tissue. We then tested paramagnetic liposomes (mean size=90 nm) for their ability to improve MRI visualization of induced thickening, using Gd-DTPA as a control. T1-weighted (T1-w), black-blood MRI of the neck area of the mice was performed before and 15 min, 45 min, and 24 hr after intravenous injection of either paramagnetic liposomes or Gd-DTPA. The collared vessel wall of mice that were injected with liposomes showed a pronounced signal enhancement of approximately 100% immediately after injection, which was sustained largely until 24 hr postinjection. In contrast, the vessel wall of all controls (left carotid artery and animals injected with Gd-DTPA) did not show significant contrast enhancement at those time points. This study demonstrates that intimal thickening in ApoE-KO mice can be effectively detected by contrast-enhanced (CE)-MRI upon injection of paramagnetic liposomes.

Animals↗

DTI-based assessment of ischemia-reperfusion in mouse skeletal muscle.

Diffusion tensor imaging (DTI) is frequently applied to characterize the microscopic geometrical properties of tissue. To establish whether and how diffusion MRI responds to transient ischemia of skeletal muscle, we studied the effects of ischemia and reperfusion using DTI and T2-weighted MRI before and during ischemia and up to 24 hr after reperfusion. Ischemia was induced by 50 min of hindlimb occlusion with or without dorsal flexor stimulation. During ischemia the apparent diffusion coefficient (ADC) tended to decrease (up to 15%), whereas the fractional anisotropy (FA) and T2 showed a varied response depending on the protocol and muscle type. During reperfusion the ADC and T2 initially increased and subsequently renormalized for the occlusion protocol. For the occlusion plus stimulation (OS) protocol, the FA was decreased by 13% and the ADC and T2 were increased by 20% and 57%, respectively, after 24 hr in the stimulated muscle complex. In the latter tissue the three DTI eigenvalues gradually increased upon reperfusion. The smallest eigenvalue (lambda3) showed the largest relative increase. Changes in DTI indices in the reperfusion phases followed a similar time course as the changes in T2. The changes in MR indices after 24 hr correlated with the tissue damage quantified with histology. The highest correlation was observed for lambda3 (R2 = 0.81). This study shows that DTI can be used to assess ischemia-induced damage to skeletal muscle.

Analysis of Variance↗

Lipid-based nanoparticles for contrast-enhanced MRI and molecular imaging.

In the field of MR imaging and especially in the emerging field of cellular and molecular MR imaging, flexible strategies to synthesize contrast agents that can be manipulated in terms of size and composition and that can be easily conjugated with targeting ligands are required. Furthermore, the relaxivity of the contrast agents, especially for molecular imaging applications, should be very high to deal with the low sensitivity of MRI. Lipid-based nanoparticles, such as liposomes or micelles, have been used extensively in recent decades as drug carrier vehicles. A relatively new and promising application of lipidic nanoparticles is their use as multimodal MR contrast agents. Lipids are amphiphilic molecules with both a hydrophobic and a hydrophilic part, which spontaneously assemble into aggregates in an aqueous environment. In these aggregates, the amphiphiles are arranged such that the hydrophobic parts cluster together and the hydrophilic parts face the water. In the low concentration regime, a wide variety of structures can be formed, ranging from spherical micelles to disks or liposomes. Furthermore, a monolayer of lipids can serve as a shell to enclose a hydrophobic core. Hydrophobic iron oxide particles, quantum dots or perfluorocarbon emulsions can be solubilized using this approach. MR-detectable and fluorescent amphiphilic molecules can easily be incorporated in lipidic nanoparticles. Furthermore, targeting ligands can be conjugated to lipidic particles by incorporating lipids with a functional moiety to allow a specific interaction with molecular markers and to achieve accumulation of the particles at disease sites. In this review, an overview of different lipidic nanoparticles for use in MRI is given, with the main emphasis on Gd-based contrast agents. The mechanisms of particle formation, conjugation strategies and applications in the field of contrast-enhanced, cellular and molecular MRI are discussed.

Contrast Media↗

Dynamic MRS and MRI of skeletal muscle function and biomechanics.

MR is a powerful technique for studying the biomechanical and functional properties of skeletal muscle in vivo in health and disease. This review focuses on 31P, 1H and 13C MR spectroscopy for assessment of the dynamics of muscle metabolism and on dynamic 1H MRI methods for non-invasive measurement of the biomechanical and functional properties of skeletal muscle. The information thus obtained ranges from the microscopic level of the metabolism of the myocyte to the macroscopic level of the contractile function of muscle complexes. The MR technology presented plays a vital role in achieving a better understanding of many basic aspects of muscle function, including the regulation of mitochondrial activity and the intricate interplay between muscle fiber organization and contractile function. In addition, these tools are increasingly being employed to establish novel diagnostic procedures as well as to monitor the effects of therapeutic and lifestyle interventions for muscle disorders that have an increasing impact in modern society.

Adenosine Triphosphate↗

MRI-guided immunotherapy development for multiple sclerosis in a primate.

Multiple sclerosis is a serious neurological disease that affects 1 in 1000 young adults in Europe and the USA. The development of an effective therapy for this enigmatic disease is plagued by the failure of many treatments to reproduce in patients the promising effects observed in animal models. This review describes a new preclinical model in a non-human primate that might help to bridge the gap between currently used animal models and the patients.

Animals↗

Quantum dots with a paramagnetic coating as a bimodal molecular imaging probe.

MRI detectable and targeted quantum dots were developed. To that aim, quantum dots were coated with paramagnetic and pegylated lipids, which resulted in a relaxivity, r(1), of nearly 2000 mM(-1)s(-1) per quantum dot. The quantum dots were functionalized by covalently linking alphavbeta3-specific RGD peptides, and the specificity was assessed and confirmed on cultured endothelial cells. The bimodal character, the high relaxivity, and the specificity of this nanoparticulate probe make it an excellent contrast agent for molecular imaging purposes.

Cells, Cultured↗

MR molecular imaging and fluorescence microscopy for identification of activated tumor endothelium using a bimodal lipidic nanoparticle.

In oncological research, there is a great need for imaging techniques that specifically identify angiogenic blood vessels in tumors on the basis of differences in the expression level of biomolecular markers. In the angiogenic cascade, different cell surface receptors, including the alphavbeta3-integrin, are strongly expressed on activated endothelial cells. In the present study, we aimed to image angiogenesis by detecting the expression of alphavbeta3 in tumor bearing mice with a combination of magnetic resonance imaging (MRI) and fluorescence microscopy. To that end, we prepared MR-detectable and fluorescent liposomes, which carry approximately 700 alphavbeta3-specific RGD peptides per liposome. RGD competition experiments and RAD-conjugated liposomes were used as controls for specificity. In vivo, both RAD liposomes and RGD liposomes gave rise to signal increase on T1-weighted MR images. It was established by the use of ex vivo fluorescence microscopy that RGD liposomes and RAD liposomes accumulated in the tumor by different mechanisms. RGD liposomes were specifically associated with activated tumor endothelium, while RAD liposomes were located in the extravascular compartment. This study demonstrates that MR molecular imaging of angiogenesis is feasible by using a targeted contrast agent specific for the alphavbeta3-integrin, and that the multimodality imaging approach gave insight into the exact mechanism of accumulation in the tumor.

Animals↗

Determination of mouse skeletal muscle architecture using three-dimensional diffusion tensor imaging.

Muscle architecture is the main determinant of the mechanical behavior of skeletal muscles. This study explored the feasibility of diffusion tensor imaging (DTI) and fiber tracking to noninvasively determine the in vivo three-dimensional (3D) architecture of skeletal muscle in mouse hind leg. In six mice, the hindlimb was imaged with a diffusion-weighted (DW) 3D fast spin-echo (FSE) sequence followed by the acquisition of an exercise-induced, T(2)-enhanced data set. The data showed the expected fiber organization, from which the physiological cross-sectional area (PCSA), fiber length, and pennation angle for the tibialis anterior (TA) were obtained. The values of these parameters ranged from 5.4-9.1 mm(2), 5.8-7.8 mm, and 21-24 degrees , respectively, which is in agreement with values obtained previously with the use of invasive methods. This study shows that 3D DT acquisition and fiber tracking is feasible for the skeletal muscle of mice, and thus enables the quantitative determination of muscle architecture.

Animals↗

The use of high-resolution magnetic resonance imaging for monitoring interbody fusion and bioabsorbable cages: an ex vivo pilot study.

OBJECT: Interbody fusion is a gradual process of graft resorption and tissue formation, ideally resulting in a bone bridge between two adjacent vertebral bodies. Initially, fibrous tissue and cartilage are formed, which subsequently are replaced by bone through the process of endochondral ossification. When cages and/or their contents are made of resorbable polymers like lactic or glycolic acids, there is a simultaneous process of implant degradation, which is eventually accompanied by reactions in the surrounding tissues. The purpose of this study was to explore the use of highresolution magnetic resonance (MR) imaging for monitoring tissue differentiation, spinal fusion, cage degradation, and eventually tissue reactions as a function of time. METHODS: Lumbar vertebral segments obtained in 14 goats with 3, 6, and 12 months of follow up (three, four, and seven animals, respectively) were available from a study of the feasibility of poly(L,D-lactic acid) cages for spinal fusion. Plain x-ray films, MR images, and histological sections were used to evaluate spinal fusion and cage resorption. The first follow-up tests revealed that MR imaging noninvasively provided three-dimensional information on cage placement, cage degradation and bone formation, and that it has potential to differentiate between the various soft tissues. CONCLUSIONS: Although the magnetic field strength and thus the resolution used were higher than normal in clinical practice, MR imaging appears to be a promising modality for the noninvasive clinical follow up of patients who undergo fusion with resorbable cages. Tissue reactions were not encountered in this study, and thus could not be evaluated.

Absorbable Implants↗

An MR-compatible device for the in situ assessment of isometric contractile performance of mouse hind-limb ankle flexors.

The goal of the present study was to develop and evaluate an isometric dynamometer for measuring mouse ankle flexor torque after electric stimulation of the nerve. The dynamometer was to be used within an magnetic resonance (MR) apparatus and should require minimal surgical intervention. To quantify the effect of the magnetic field on contractile parameters, measurements were performed both outside and inside the MR apparatus. The effect of magnetic field gradient switching that accompanies rapid MR scanning was tested also. The set-up required no surgical intervention except for chronic implantation of an electrode. The dynamometer has a high mechanical frequency response (270 Hz). Measured muscle strengths were identical outside and inside the MR scanner. However, during fast magnetic field gradient switching, the variability increased and the measured strength decreased slightly (7%). The noise level of the dynamometer (0.02-0.03 N.mm) was low compared with the strength of the dorsal flexors (2 N.mm). Fast gradient switching increased the noise level (0.07 N.mm). The dynamometer had no observable adverse effects on the quality of the MR images of the mouse hind limb. We conclude that the dynamometer enables accurate measurements of mechanical muscle performance during exercise protocols within an MR apparatus under physiological conditions.

Animals↗

A liposomal system for contrast-enhanced magnetic resonance imaging of molecular targets.

Pegylated paramagnetic and fluorescent immunoliposomes were designed to enable the parallel detection of the induced expression of molecular markers on endothelial cells with magnetic resonance imaging (MRI) and fluorescence microscopy. MRI is capable of three-dimensional noninvasive imaging of opaque tissues at near cellular resolution, while fluorescence microscopy can be used to investigate processes at the subcellular level. As a model for the expression of a molecular marker, human umbilical vein endothelial cells (HUVEC) were treated with the pro-inflammatory cytokine tumor necrosis factor alpha (TNFalpha) to upregulate the expression of the adhesion molecule E-selectin/CD62E. E-selectin-expressing HUVEC were incubated with pegylated paramagnetic fluorescently labeled liposomes carrying anti-E-selectin monoclonal antibody as a targeting ligand. Both MRI and fluorescence microscopy revealed the specific association of the liposomal MR contrast agent with stimulated HUVEC. This study suggests that this newly developed system may serve as a useful diagnostic tool to investigate pathological processes in vivo with MRI.

Antibodies↗

Annexin A5-functionalized bimodal lipid-based contrast agents for the detection of apoptosis.

Apoptosis, or programmed cell death, plays an important role in the etiology of a variety of diseases, including cancer and myocardial infarction. Visualization of apoptosis would allow both early detection of therapy efficiency and evaluation of disease progression. To that aim, we synthesized two types of lipid-based bimodal contrast agents that enable the detection of apoptotic cells with both MRI and optical techniques. MR contrast was provided either by entrapment of iron oxide particles within pegylated micelles or by incorporation of Gd-DTPA-bis(stearylamide) (Gd-DTPA-BSA) lipids within the lipid bilayer of pegylated liposomes. The resulting contrast agents were approximately 10 and 100 nm in diameter, respectively. Additional fluorescent lipids were incorporated in the lipid (bi)layer of the contrast agents to allow parallel detection with optical methods. Multiple human recombinant annexin A5 molecules were covalently coupled to introduce specificity for apoptotic cells. Both annexin A5-conjugated contrast agents were shown to significantly increase the relaxation rates of apoptotic cell pellets compared to untreated control cells and apoptotic cells that were treated with nonfunctionalized nanoparticles. Increased relaxation rates were confirmed to originate from association of the contrast agents to apoptotic cells by confocal microscopy. The targeted nanoparticles presented in this study, which differ both in size and in magnetic properties, may have applications for the in vivo detection of apoptosis.

Annexin A5↗

Annexin A5-conjugated quantum dots with a paramagnetic lipidic coating for the multimodal detection of apoptotic cells.

Apoptosis, or programmed cell death, plays an important role in the etiology of a variety of diseases, including cancer. Visualization of apoptosis would allow both early detection of therapy efficiency and evaluation of disease progression. To that aim we developed a novel annexin A5-conjugated bimodal nanoparticle. The nanoparticle is composed of a quantum dot that is encapsulated in a paramagnetic micelle to enable its use both for optical imaging and MRI. Multiple recombinant human annexin A5 protein molecules were covalently coupled to the nanoparticle for targeting. In this study the specificity of the annexin A5-conjugated nanoparticles for apoptotic cells was demonstrated both with fluorescence microscopy and MRI, which confirms its potential for the detection of apoptosis with both imaging modalities in vivo.

Annexin A5↗