PubMed Health⌕ Search

Biomedical subjects

Guy Cloutier

Publications and source records attributed to Guy Cloutier.

At least 19 recordsLinked to original sources

Optimization of spatial resolution for peripheral magnetic resonance angiography.

RATIONALE AND OBJECTIVES: To determine optimum spatial resolution when imaging peripheral arteries with magnetic resonance angiography (MRA). MATERIALS AND METHODS: Eight vessel diameters ranging from 1.0 to 8.0 mm were simulated in a vascular phantom. A total of 40 three-dimensional flash MRA sequences were acquired with incremental variations of fields of view, matrix size, and slice thickness. The accurately known eight diameters were combined pairwise to generate 22 "exact" degrees of stenosis ranging from 42% to 87%. Then, the diameters were measured in the MRA images by three independent observers and with quantitative angiography (QA) software and used to compute the degrees of stenosis corresponding to the 22 "exact" ones. The accuracy and reproducibility of vessel diameter measurements and stenosis calculations were assessed for vessel size ranging from 6 to 8 mm (iliac artery), 4 to 5 mm (femoro-popliteal arteries), and 1 to 3 mm (infrapopliteal arteries). Maximum pixel dimension and slice thickness to obtain a mean error in stenosis evaluation of less than 10% were determined by linear regression analysis. RESULTS: Mean errors on stenosis quantification were 8.8% +/- 6.3% for 6- to 8-mm vessels, 15.5% +/- 8.2% for 4- to 5-mm vessels, and 18.9% +/- 7.5% for 1- to 3-mm vessels. Mean errors on stenosis calculation were 12.3% +/- 8.2% for observers and 11.4% +/- 15.1% for QA software (P = .0342). To evaluate stenosis with a mean error of less than 10%, maximum pixel surface, the pixel size in the phase direction, and the slice thickness should be less than 1.56 mm2, 1.34 mm, 1.70 mm, respectively (voxel size 2.65 mm3) for 6- to 8-mm vessels; 1.31 mm2, 1.10 mm, 1.34 mm (voxel size 1.76 mm3), for 4- to 5-mm vessels; and 1.17 mm2, 0.90 mm, 0.9 mm (voxel size 1.05 mm3) for 1- to 3-mm vessels. CONCLUSION: Higher spatial resolution than currently used should be selected for imaging peripheral vessels.

Constriction, Pathologic↗

Characterization of circulatory disorders in beta-thalassemic mice by noninvasive ultrasound biomicroscopy.

Beta-thalassemia is an inherited hematological disease caused by a decrease or absence of production of beta-globin that requires chronic therapeutic interventions. This condition leads to important arterial and venous thromboembolic events, transitory ischemic attacks, and microcirculatory obstructions, indicative of circulatory disturbances. To investigate the presence of microcirculatory disorders without the confounding effect of treatments, we used beta-thalassemic mice with typical clinical characteristics of human beta-thalassemia major. One impediment to the understanding of microcirculatory physiology, in particular for beta-thalassemic mice, has been the lack of an appropriate noninvasive imaging approach. We thus developed a novel noninvasive high-frequency ultrasound imaging method to evaluate murine vascular hemodynamic properties. In our beta-thalassemic mice, total peripheral vascular resistance was significantly increased (P < 0.01) compared with wildtype littermates, whereas mean blood pressure, heart rate, and cardiac output were similar (P = nonsignificant). Importantly, the vascular hemodynamics in beta-thalassemic mice were significantly affected according to the Pourcelot indexes measured in the common carotid artery and abdominal aorta (P < 0.01 and P < 0.05, respectively). Hence, our beta-thalassemia characterization of vascular hemodynamics by noninvasive ultrasonic approaches proves the existence and provides unique quantitative assessment of microcirculatory flow disturbances in those mice.

Animals↗

Influence of multiple stenoses on echo-Doppler functional diagnosis of peripheral arterial disease: a numerical and experimental study.

The objective of this paper was to evaluate the ability of the peak systolic velocity ratio (PSVR) and pressure drop (DeltaP) to detect and grade multiple stenoses in lower limb mimicking arteries. Numerical simulations and experiments in vascular phantoms allowing ultrasound duplex scanning and pressure measurements were used to investigate simple and double stenotic arterial segments. Inter-stenotic distance, severity of the distal stenosis, flow rate and flow profile (steady or pulsatile) were the tested parameters. The three-dimensional simulations considered the turbulent two-equation Wilcox model. Agreements were observed between the experimental and numerical results for DeltaP and PSVR. The maximum PSVR along the artery was shown to be mainly influenced by the severity of the most important stenosis. However, mutual interactions of both stenoses on hemodynamics were noted. By using the clinical PSVR threshold used to diagnose critical lesions (PSVR > or = 2), its longitudinal evolution along the artery poorly reflected the length of the lesion or the impact of surrounding stenoses. This investigation confirms the interaction between adjacent stenoses on hemodynamics and its impact on the Doppler ultrasound index PSVR.

Animals↗

Assessment by transient elastography of the viscoelastic properties of blood during clotting.

Blood clotting is a natural process that can be both beneficial and life-threatening for the human body. It allows the maintenance of hemostasis after vascular injury, but it can also cause deep vein thrombosis and heart stroke. This study aimed better to understand the clotting process from a biomechanical point of view by using an acoustic method. The long-term objective is the staging of the age of clots in deep veins for therapy planning. The transient elastography method using a shear elasticity probe served to evaluate the shear wave velocity (V(S)) and shear wave attenuation (alpha(S)) of porcine whole blood during in vitro clot formation. By solving an inverse problem, it was then possible to provide images of the elasticity (mu(B)) and of the viscosity (eta(B)) from clotting blood. The time-varying elasticity and viscosity were very similar to what has been observed for the sol-gel transition of polymers. The mechanical properties of blood clot, which were modified by varying the hematocrit and by adding heparin or fibrinogen, were clearly assessed by the transient elastography technique. It is concluded that the shear elasticity probe is an appropriate tool to quantify and follow the sol-gel transition of blood during clotting.

Animals↗

Intravascular ultrasound image segmentation: a three-dimensional fast-marching method based on gray level distributions.

Intravascular ultrasound (IVUS) is a catheter based medical imaging technique particularly useful for studying atherosclerotic disease. It produces cross-sectional images of blood vessels that provide quantitative assessment of the vascular wall, information about the nature of atherosclerotic lesions as well as plaque shape and size. Automatic processing of large IVUS data sets represents an important challenge due to ultrasound speckle, catheter artifacts or calcification shadows. A new three-dimensional (3-D) IVUS segmentation model, that is based on the fast-marching method and uses gray level probability density functions (PDFs) of the vessel wall structures, was developed. The gray level distribution of the whole IVUS pullback was modeled with a mixture of Rayleigh PDFs. With multiple interface fast-marching segmentation, the lumen, intima plus plaque structure, and media layers of the vessel wall were computed simultaneously. The PDF-based fast-marching was applied to 9 in vivo IVUS pullbacks of superficial femoral arteries and to a simulated IVUS pullback. Accurate results were obtained on simulated data with average point to point distances between detected vessel wall borders and ground truth <0.072 mm. On in vivo IVUS, a good overall performance was obtained with average distance between segmentation results and manually traced contours <0.16 mm. Moreover, the worst point to point variation between detected and manually traced contours stayed low with Hausdorff distances <0.40 mm, indicating a good performance in regions lacking information or containing artifacts. In conclusion, segmentation results demonstrated the potential of gray level PDF and fast-marching methods in 3-D IVUS image processing.

Algorithms↗

Sol-gel transition in agar-gelatin mixtures studied with transient elastography.

Using the shear wave propagation in solids, the transient elastography technique has been developed to assess the elastic properties of soft tissues. Here, a new approach of transient elastography allows assessing the viscoelastic properties of soft tissues. In this paper, the method is used to follow-up the sol-gel transition of an agar-gelatin mixture noninvasively. The shear wave velocity and shear wave attenuation through the mixture were continuously monitored in the audible range of frequencies (from 50 Hz to 200 Hz). The observed changes in velocities and attenuations as a function of frequency confirmed the validity of the Voigt's model to describe the gel at its stable mechanical state. By a simple inverse problem approach, based on the one-dimensional (1-D) Helmholtz equation, the elasticity and the viscosity of such a mixture were recovered as a function of time. The results obtained are in good agreement with the literature and theoretical predictions. Overall, they demonstrate the high sensitivity of the transient elastography measurements to the rheological parameter changes in agar-gelatin mixtures during gelation.

Agar↗

Implant degradation and poor healing after endovascular repair of abdominal aortic aneurysms: an analysis of explanted stent-grafts.

PURPOSE: To study explanted stent-grafts to achieve a better understanding of the mechanisms of failure after endovascular treatment of abdominal aortic aneurysms (AAA). METHODS: Twelve stent-grafts were harvested at autopsy (n=3) or during surgical conversion (n=9). Device alterations were investigated by macroscopic examination, radiography, and surface analysis techniques. Healing around the implants was studied via histology and immunohistochemistry, with particular attention to the stent-graft/tissue interface. RESULTS: Degradation was more important with Vanguard stent-grafts (off the market) than with AneuRx and Talent stent-grafts, but rupture of nitinol wires and poor surface finish in Talent stent-grafts raise concern about their corrosion resistance and long-term stability. Poor healing was observed around stent-grafts even after several years of implantation, with absence of vascular smooth muscle cells, fibroblasts, and collagen formation. In addition to the well-known foreign body reaction around the graft, numerous polymorphonuclear cells characteristic of the first step of healing were present in tissues around stent-grafts retrieved at surgical conversion. Factors explaining the lack of tissue organization around stent-grafts are discussed. CONCLUSION: The long-term stability of implants remains a concern and requires more transparency from manufacturers regarding the surface properties of their devices. Lack of neointima formation impairs biological fixation of the implant to the vessel wall, leading to possible endoleaks and migration. New-generation stent-grafts promoting biological fixation should be developed to improve clinical outcomes of this minimally invasive treatment.

Aged↗

Non-invasive high-frequency vascular ultrasound elastography.

Non-invasive vascular elastography (NIVE) was recently introduced to characterize mechanical properties of superficial arteries. In this paper, the feasibility of NIVE and its applicability in the context of high-frequency ultrasound imaging is investigated. First, experiments were performed in vitro on vessel-mimicking phantoms. Polyvinyl alcohol cryogel was used to create two double-layer vessels with different mechanical properties. In both cases, the stiffness of the inner layer was made softer. Radial stress was applied within the lumen of the phantoms by applying incremental static pressure steps with a column of a flowing mixture of water-glycerol. The vessel phantoms were insonified at 32 MHz with an ultrasound biomicroscope to provide cross-section sequences of radio-frequency (RF) ultrasound data. The Lagrangian speckle model estimator (LSME) was used to assess the two-dimensional-strain tensors, and the composite Von Mises elastograms were computed. A new implementation of the LSME based on the optical flow equations was introduced. Deformation parameters were estimated using an inversion algorithm. For each in vitro experiment, both layers of approximately 1 mm were distinguished. Second, the use of the method for the purpose of studying small vessels (MicroNIVE) in genetically engineered rodents was introduced. Longitudinal scans of the carotid artery were performed at 40 MHz. The in vivo results give confidence in the feasibility of MicroNIVE as a potential tool to non-invasively study the impact of targeted genes on vascular remodelling in rodents.

Algorithms↗

Automatic 3D segmentation of intravascular ultrasound images using region and contour information.

Intravascular ultrasound (IVUS) produces images of arteries that show the lumen in addition to the layered structure of the vessel wall. A new automatic 3D IVUS fast-marching segmentation model is presented. The method is based on a combination of region and contour information, namely the gray level probability density functions (PDFs) of the vessel structures and the image gradient. Accurate results were obtained on in-vivo and simulated data with average point to point distances between detected vessel wall boundaries and validation contours below 0.105 mm. Moreover, Hausdorff distances (that represent the worst point to point variations) resulted in values below 0.344 mm, which demonstrate the potential of combining region and contour information in a fast-marching scheme for 3D automatic IVUS image processing.

Algorithms↗

3D elastic registration of vessel structures from IVUS data on biplane angiography.

RATIONALE AND OBJECTIVES: Planar angiograms and intravascular ultrasound (IVUS) imaging provide important insight for the evaluation of atherosclerotic diseases and blood flow abnormalities. The construction of realistic three-dimensional models is essential to efficiently follow the progression of arterial plaque. This requires an explicit localization of IVUS frames from angiograms. Because of the difficulties encountered when trying to track the position of an IVUS transducer, we propose an elastic registration approach that relies on a virtual catheter path. MATERIALS AND METHODS: Deformable surface models of the lumen and external wall are constructed from segmented IVUS contours. A crude registration is obtained using a three-dimensional vessel centerline, reconstructed from two calibrated angiograms. Robust optimization of the virtual catheter path, position, absolute orientation, and regulation of the external wall shape is performed until near-perfect alignment of the back-projected silhouettes on image edges is reached. RESULTS: Visual assessment of the reconstructed vessels showed a good superposition of virtual models on the angiograms. We measured a 0.4-mm residual error value. A preliminary study of convergence properties on 15 datasets showed that initial absolute orientation may affect the solution. However, for follow-ups, coherent solutions were found among datasets. CONCLUSION: The advantages of the virtual catheter path approach are demonstrated. Future work will look at ways to single out the true solution with a better use of the available information in both modalities and additional validation studies on improved datasets.

Algorithms↗

On the potential of the Lagrangian speckle model estimator to characterize atherosclerotic plaques in endovascular elastography: in vitro experiments using an excised human carotid artery.

Endovascular ultrasound (US) elastography (EVE) was introduced to supplement endovascular US echograms in the assessment of vessel lesions and for endovascular therapy planning. Indeed, changes in the vascular tissue stiffness are characteristic of vessel wall pathologies and EVE appears as a very appropriate imaging technique to outline the elastic properties of vessel walls. Recently, a model-based approach was proposed to assess tissue motion in EVE. It specifically consists of a nonlinear minimization algorithm that was adapted to speckle motion estimation. Regarding the theoretical framework, such an approach considers the speckle as a material property; this assumption then led to the derivation of the optical flow equations, which were suitably combined with the Lagrangian speckle model estimator to provide the full 2-D polar strain tensor. In this study, the proposed algorithm was validated in vitro using a fresh excised human carotid artery. The experimental setup consisted of a cardiovascular imaging system (CVIS) US scanner, working with a 30-MHz mechanical rotating single-element transducer, a digital oscilloscope and a pressuring system. A sequence of radiofrequency (RF) images was collected while incrementally adjusting the intraluminal static pressure steps. The results showed the potential of this 2-D algorithm to characterize and to distinguish an atherosclerotic plaque from the normal vascular tissue. Namely, the geometry as well as some mechanical characteristics of the detected plaque were in good agreement with histology. The results also suggested that there might exist a range of intraluminal pressures for which plaque detectability is optimal.

Algorithms↗

Effect of red cell clustering and anisotropy on ultrasound blood backscatter: a Monte Carlo study.

When flowing at a low shear rate, blood appears hyperechogenic on ultrasound B-scans. The formation of red blood cell (RBC) aggregates that also alters blood viscosity is the microscopic mechanism explaining this acoustical phenomenon. In this study, Monte Carlo simulations were performed to predict how RBC clustering increases ultrasound scattering by blood. A bidimensional Gibbs-Markov random point process parameterized by the adhesion energy epsilon and an anisotropy index nu was used to describe RBC positions for a hematocrit H = 40%. The frequency dependence of the backscattering coefficient chi(f) was computed using Born approximation. The backscattering coefficient chi0 at 5 MHz and the spectral slopes n(x) and n(y) (chi alpha f(nx) or f(ny)) measured, respectively, when the insonification is parallel and perpendicular with the RBC cluster axis were then extracted. Under isotropic conditions, chi0 increased up to 7 dB with epsilon and n(x) = n(y) decreased from 4.2 to 3.4. Under anisotropic conditions, the backscattering was stronger perpendicularly to aggregate axis, resulting in n(x) < n(y). The anisotropy in scattering appeared more pronounced when epsilon or nu increased. These two dimensional results generally predict that low-frequency blood backscatter is related to cluster dimension, and higher-frequency properties are affected by finer morphological features as anisotropy. This numerically establishes that ultrasound backscatter spectroscopy on a large frequency range is pertinent to characterize in situ hemorheology.

Algorithms↗

Effects of aggregation of red cells and linear velocity gradients on the correlation-based method for quantitative IVUS blood flow at 20 MHz.

Recent computer simulations suggest that the presence of aggregates of red blood cells (RBCs), at random angles and lengths, does not affect the measurements of blood flow transverse to the ultrasound (US) beam direction using a correlation-based method and an intravascular (IV) US array catheter. However, in case of aggregates of RBCs aligned with the flow, measurements of simulated blood velocity are affected. Blood velocity gradients were also shown not to influence the correlation-based method for blood velocity estimation. The objective of this study was to quantify the influence of aggregates of RBCs and blood velocity gradients on the correlation-based method during in vitro experiments. For this purpose, measurements were performed on washed RBCs (no aggregation), normal human blood, and two types of diseased blood in which a lower or a higher level of aggregation was present. The decorrelation pattern of a circular US transducer as a function of transverse blood flow was studied using a Couette system. Changing the shear rate of the Couette system modified the aggregation level of RBCs and the velocity gradient. With the exception of the results at low shear rates and abnormally high aggregation levels, agreements were found between the autoconvolution of the acoustical beam (reference curve) and the radiofrequency (RF) decorrelation patterns. For the high shear rate present in coronary arteries, the correlation-based method for blood flow estimation should not be influenced by these phenomena.

Adult↗

CT and MR imaging of nitinol stents with radiopaque distal markers.

PURPOSE: To evaluate imaging characteristics and artifacts of a nitinol stent with distal tantalum markers with computed tomography (CT) angiography and magnetic resonance (MR) angiography. MATERIALS AND METHODS: A vascular phantom was built to simulate in-stent restenosis. A nitinol stent with tantalum markers (Luminexx stent) was evaluated with CT angiography in different orientations relative to the z-axis and with MR angiography in different positions relative to both B0 and the readout gradient. Stenosis measurements were compared with conventional digital subtraction angiography for both modalities. In-stent signal intensity obtained with different flip angles was assessed in two nitinol stents with distal markers (Luminexx stent and SMART stent) and one without markers (Memotherm-FLEXX stent). RESULTS: Stenosis detection was not possible with CT angiography when the stent was perpendicular to the z-axis because of streak-like artifacts induced by tantalum markers. Stenosis evaluation with multiplanar reformation was accurate when the stent was in parallel and oblique orientations relative to the table axis. With MR angiography, metallic artifacts were mostly related to the stent orientation with B0, whereas orientation of the readout gradient had little influence. The mean error (overestimation) for stenosis measurements varied between 0.1% and 7.4% for CT imaging in parallel and oblique positions and 3.6% and 9.5% for MR imaging. Higher flip angles did not improve signal intensity inside the three stents tested. CONCLUSION: CT and MR angiography can be used for evaluating the patency of stents with distal markers that are parallel or oblique relative to the table axis (iliac, carotid, or femoral stents). MR angiography is preferred if the stent is perpendicular to the table axis (renal stent).

Alloys↗

Endovascular aortic aneurysm repair with stent-grafts: experimental models can reproduce endoleaks.

PURPOSE: To develop canine aneurysm models that can reproduce type II endoleaks after endovascular aneurysm repair (EVAR) with stent-grafts. MATERIALS AND METHODS: A fusiform infrarenal abdominal aortic aneurysm model (AAA) was surgically created with a jugular vein patch, while preserving collateral vessels (n = 3). To allow comparative studies within the same animal, a bilateral iliac aneurysm model was also constructed with venous patches and surgical re-implantation of the sacroiliac trunk (n = 3). Stent-grafts were implanted by femoral approach at least 2 months later in both aortic and iliac models. Follow-up imaging was performed by Doppler ultrasound (US) and angiography until animals were killed 3 months after EVAR. RESULTS: Angiography revealed immediate type II leaks in all cases. Leaks were still present at autopsy 3 months after EVAR in all cases, and were revealed at pre-death angiography in all but one case. At autopsy, leaks were characterized by the presence of large endothelialized channels that formed within the thrombus between the stent-graft and the aneurysmal wall. CONCLUSION: As shown in this pilot study, persistent type II leaks after EVAR can be reproduced in aortic and iliac animal models. The iliac model can be created bilaterally in the same animal, thus allowing for comparative evaluation of different therapies. These models could be used to better understand the mechanisms of endoleak, and to assess future developments aimed to improve the outcomes after EVAR.

Aneurysm↗

Noninvasive vascular elastography: theoretical framework.

Changes in vessel wall elasticity may be indicative of vessel pathologies. It is known, for example, that the presence of plaque stiffens the vascular wall, and that the heterogeneity of its composition may lead to plaque rupture and thrombosis. Another domain of application where ultrasound elastography may be of interest is the study of vascular wall elasticity to predict the risk of aneurysmal tissue rupture. In this paper, this technology is introduced as an approach to noninvasively characterize superficial arteries. In such a case, a linear array ultrasound transducer is applied on the skin over the region of interest, and the arterial tissue is dilated by the normal cardiac pulsation. The elastograms, the equivalent elasticity images, are computed from the assessment of the vascular tissue motion. Investigating the forward problem, it is shown that motion parameters might be difficult to interpret; that is because tissue motion occurs radially within the vessel wall while the ultrasound beam propagates axially. As a consequence of that, the elastograms are subjected to hardening and softening artefacts, which are to be counteracted. In this paper, the Von Mises (VM) coefficient is proposed as a new parameter to circumvent such mechanical artefacts and to appropriately characterize the vessel wall. Regarding the motion assessment, the Lagrangian estimator was used; that is because it provides the full two-dimensional strain tensor necessary to compute the VM coefficient. The theoretical model was validated with biomechanical simulations of the vascular wall properties. The results allow believing in the potential of the method to differentiate hard plaques and lipid pools from normal vascular tissue. Potential in vivo implementation of noninvasive vascular elastography to characterize abdominal aneurysms and superficial arteries such as the femoral and the carotid is discussed.

Algorithms↗

A multimodality vascular imaging phantom with fiducial markers visible in DSA, CTA, MRA, and ultrasound.

The objective was to design a vascular phantom compatible with digital subtraction angiography, computerized tomography angiography, ultrasound and magnetic resonance angiography (MRA). Fiducial markers were implanted at precise known locations in the phantom to facilitate identification and orientation of plane views from three-dimensional (3-D) reconstructed images. A vascular conduit connected to tubing at the extremities of the phantom ran through an agar-based gel filling it. A vessel wall in latex was included around the conduit to avoid diffusion of contrast agents. Using a lost-material casting technique based on a low melting point metal, geometries of pathological vessels were modeled. During the experimental testing, fiducial markers were detectable in all modalities without distortion. No leak of gadolinium through the vascular wall was observed on MRA after 5 hours. Moreover, no significant deformation of the vascular conduit was noted during the fabrication process (confirmed by microtome slicing along the vessel). The potential use of the phantom for calibration, rescaling, and fusion of 3-D images obtained from the different modalities as well as its use for the evaluation of intra- and inter-modality comparative studies of imaging systems are discussed. In conclusion, the vascular phantom can allow accurate calibration of radiological imaging devices based on x-ray, magnetic resonance and ultrasound and quantitative comparisons of the geometric accuracy of the vessel lumen obtained with each of these methods on a given well defined 3-D geometry.

Agar↗

Geometrical accuracy and fusion of multimodal vascular images: a phantom study.

The aim of this work was to compare the geometrical accuracy of x-ray angiography, magnetic resonance imaging (MRI), x-ray computed tomography (XCT), and ultrasound imaging (B-mode and IVUS, or intravascular ultrasound) for measuring the lumen diameters of blood vessels. An image fusion method was also developed to improve these measurements. The images were acquired from a phantom that mimic vessels of known diameters. After acquisition, the multimodal images were coregistered by manual alignment of fiducial markers, and then by maximization of mutual information. The fusion method was performed by means of a fuzzy logic modeling approach followed by a combination process based on a possibilistic theory. The results showed (i) the better geometrical accuracy of XCT and IVUS compared to the other modalities, and (ii) the better accuracy and smaller variability of fused images compared to single modalities, with respect to most diameters investigated. For XCT, the error varied from 0.4% to 5.4%, depending on the vessel diameter that ranged from 0.93 to 6.24 mm. For IVUS, the error ranged from -0.3% to 1.7% but the smallest vessel (0.93 mm) could not be investigated because of the probe size. Compared to others fusion schemes, the XCT-MRI fused images provided the best results for both accuracy (from -1.6% to 0.2% for the three largest vessels) and robustness (mean relative error of 1.9%). To conclude, this work underlined both the usefulness of the multimodality vascular phantom as a validation tool and the utility of image fusion in the vascular context.

Angiography↗