PubMed Health⌕ Search

Biomedical subjects

Guy Marchal

Publications and source records attributed to Guy Marchal.

At least 19 recordsLinked to original sources

Fetal body volume: use at MR imaging to quantify relative lung volume in fetuses suspected of having pulmonary hypoplasia.

PURPOSE: To retrospectively determine an algorithm based on fetal body volume (FBV) by using magnetic resonance (MR) imaging to calculate relative lung volume in fetuses with normally developed lungs and prospectively assess the use of this algorithm in predicting pulmonary hypoplasia in the late second and early third trimesters for fetuses at risk for pulmonary hypoplasia. MATERIALS AND METHODS: Oral informed consent was obtained for the prospective component of this ethics committee-approved study. MR imaging lung volumetry was performed in 36 fetuses with normally developed lungs between 18 and 39 weeks gestational age by using T2-weighted single-shot fast spin-echo imaging in fetal transverse and sagittal planes. Findings were then correlated with biometric variables and gestational age. The best-performing algorithm was applied to 37 fetuses (between 18 and 29 weeks gestational age) at risk for pulmonary hypoplasia to determine observed-expected lung volume ratio. This group was stratified according to pregnancy management, and observed-expected ratios were correlated with outcome. In fetuses with isolated congenital diaphragmatic hernia (CDH) (n = 19), observed-expected ratio was correlated with lung-head ratio, neonatal survival in pregnancies managed expectantly (n = 13), and/or lung-body weight ratio at necropsy (n = 9). For that purpose, linear regression correlation was used with the Pearson correlation coefficient; P < .05 was considered to indicate a significant difference. RESULTS: Total fetal lung volume correlated best with total FBV (r = 0.96, P < .05). Observed-expected ratio based on FBV correlated with lung-head ratio in patients with CDH (r = 0.71, P < .001) and with lung-body weight ratio at necropsy (r = 0.68, P < .05) and could be used to help predict neonatal survival. CONCLUSION: FBV measured with MR imaging can be used as a single parameter in an algorithm and showed closest correlation with normal total fetal lung volume. In the transition from second to third trimester, this algorithm enabled calculation of the observed-expected ratio and prediction of outcome in fetuses at risk for pulmonary hypoplasia.

Algorithms↗

Delayed perfusion phenomenon in a rat stroke model at 1.5 T MR: an imaging sign parallel to spontaneous reperfusion and ischemic penumbra?

INTRODUCTION: Delayed perfusion (DP) sign at MR imaging was reported in stroke patients. We sought to experimentally elucidate its relation to spontaneous reperfusion and ischemic penumbra. METHODS: Stroke was induced by photothrombotic occlusion of middle cerebral artery in eight rats and studied up to 72 h using a 1.5 T MR scanner with T2 weighted imaging (T2WI), diffusion weighted imaging (DWI), and dynamic susceptibility contrast-enhanced perfusion weighted imaging (DSC-PWI). Relative signal intensity (rSI), relative lesion volume (rLV), relative cerebral blood flow (rCBF), PWI(rLV)-DWI(rLV) mismatch (penumbra) and DP(rLV) were quantified and correlated with neurological deficit score (NDS), triphenyl tetrazolium chloride (TTC) staining, microangiography (MA) and histopathology. RESULTS: The rSI and rLV characterized this stroke model on different MRI sequences and time points. DSC-PWI reproduced cortical DP in all rats, where rCBF evolved from 88.9% at 1 h through 64.9% at 6 h to 136.3% at 72 h. The PWI(rLV)-DWI(rLV) mismatch reached 10+/-5.4% at 1 h, remained positive through 12 h and decreased to -3.3+/-4.5% at 72 h. The incidence and rLV of the DP were well correlated with those of the penumbra (p<0.01, r(2)=0.85 and p<0.0001, r(2)=0.96, respectively). Shorter DP durations and more collateral arterioles occurred in rats without (n=4) than with (n=4) cortex involvement (p<0.05). Rats without cortex involvement tended to earlier reperfusion and a lower NDS. Microscopy confirmed MRI, MA and TTC findings. CONCLUSIONS: In this rat stroke model, we reproduced clinically observed DP on DSC-PWI, confirmed spontaneous reperfusion, and identified the penumbra extending to 12h post-ischemia, which appeared interrelated.

Animals↗

Assessment of bone segmentation quality of cone-beam CT versus multislice spiral CT: a pilot study.

OBJECTIVES: The objective of this study was to quantitatively assess the quality of jawbone models generated from cone beam computed tomography (CBCT) by comparison with similar models obtained from multislice spiral computed tomography (MSCT). MATERIAL AND METHODS: Three case studies were performed involving images of anthropomorphic head phantoms and real patients acquired with 3 CBCT (NewTom 9000 DVT, Accuitomo 3D, and i-CAT) and 2 MSCT scanners (Somatom VolumeZoom and Lightspeed). Bone was segmented from the CBCT and MSCT images using global thresholding. CBCT vs MSCT segmentation differences were assessed by comparing bone thickness measurements at anatomically corresponding sites, identified automatically by CBCT to MSCT image registration. RESULTS: There was a statistically significant difference between the MSCT and CBCT segmented bone thicknesses, varying from 0.05 +/- 0.47 mm (i-CAT) up to 1.2 +/- 1.00 mm (3D Accuitomo, posterior maxilla). CONCLUSIONS: An automated, reproducible, and observer-independent method has been developed to assess the quality of CBCT bone models using MSCT as a clinically established method of reference. Our validation method is generally applicable in cases where no geometric ground-truth is available.

Algorithms↗

Liver tumor model with implanted rhabdomyosarcoma in rats: MR imaging, microangiography, and histopathologic analysis.

In compliance with institutional regulations for care and use of laboratory animals, the aim of this study was to establish and characterize a rodent liver tumor model to provide a platform for preclinical assessment of new diagnostic and therapeutic strategies. A rhabdomyosarcoma tumor was implanted in the right and left liver lobes of 20 rats, for a total of 40 tumors. T1- and T2-weighted magnetic resonance (MR) images, diffusion-weighted images, and dynamic susceptibility contrast agent-enhanced perfusion-weighted images were obtained up to 16 days after tumor implantation and were compared with postmortem three-dimensional computed tomographic (CT) images, digital microangiograms, and histopathologic findings. Fifteen tumors were examined with proton ((1)H) MR spectroscopy. All tumors grew, with a mean volume doubling time of 2.2 days +/- 0.9 (standard deviation) and a final size of 591 mm(3)+/- 124. The rhabdomyosarcoma tumor showed hypervascularity at MR imaging, three-dimensional CT, microangiography, and histologic analysis. On dynamic susceptibility contrast-enhanced perfusion-weighted images, the maximum signal intensity decrease differed in time and extent between the tumor and the liver, with a significantly (P < .001) higher relative blood volume, relative blood flow, and permeability value in the tumor than in the liver. With (1)H MR spectroscopy, the rhabdomyosarcoma tumor and the liver featured significant (P < .001) choline and lipid peaks, respectively. Implantation of a rhabdomyosarcoma tumor in the livers of rats is feasible and reproducible, and this animal model seems promising for future testing of new diagnostic and therapeutic strategies.

Angiography↗

First preclinical evaluation of mono-[123I]iodohypericin as a necrosis-avid tracer agent.

PURPOSE: We have labelled hypericin, a polyphenolic polycyclic quinone found in St. John's wort (Hypericum perforatum), with( 123)I and evaluated mono-[(123)I]iodohypericin (MIH) as a potential necrosis-avid diagnostic tracer agent. METHODS: MIH was prepared by an electrophilic radioiodination method. The new tracer agent was evaluated in animal models of liver infarction in the rat and heart infarction in the rabbit using single-photon emission computed tomography (SPECT), triphenyltetrazolium chloride (TTC) histochemical staining, serial sectional autoradiography and microscopy, and radioactivity counting techniques. RESULTS: Using in vivo SPECT imaging, hepatic and cardiac infarctions were persistently visualised as well-defined hot spots over 48 h. Preferential uptake of the tracer agent in necrotic tissue was confirmed by perfect match of images from post-mortem TTC staining, autoradiography (ARX) and histology. Radioactivity concentration in infarcted tissues was over 10 times (liver; 3.51% ID/g in necrotic tissue vs 0.38% ID/g in normal tissue at 60 h p.i.) and over 6 times (myocardium; 0.36% ID/g in necrotic tissue vs 0.054% ID/g in normal tissue; ratios up to 18 for selected parts on ARX images) higher than in normal tissues. CONCLUSION: The results suggest that hypericin derivatives may serve as powerful necrosis-avid diagnostic agents for assessment of tissue viability.

Animals↗

Magnetic resonance imaging after radiofrequency ablation in a rodent model of liver tumor: tissue characterization using a novel necrosis-avid contrast agent.

We exploited a necrosis-avid contrast agent ECIV-7 for magnetic resonance imaging (MRI) in rodent liver tumors after radiofrequency ablation (RFA). Rats bearing liver rhabdomyosarcoma (R1) were randomly allocated to three groups: group I, complete RFA, group II, incomplete RFA, and group III, sham ablation. Within 24 h after RFA, T1-weighted (T1-w) MRI was performed before and after injection of ECIV-7 at 0.05 mmol/kg and followed up from 6-24 h. Signal intensities (SIs) were measured with relative enhancement (RE) and contrast ratio (CR) calculated. The MRI findings were verified histomorphologically. On plain T1-w MRI the contrasts between normal liver, RFA lesion, residual and/or intact tumor were vague. Early after administration of ECIV-7, the liver SI was strongly enhanced (RE=40-50%), leaving the RFA lesion as a hypointense region in groups I and II. At delayed phase, two striking peri-ablational enhancement patterns appeared (RE=90% and CR=1.89%), i.e., "O" type of hyperintense rim in group I and "C" type of incomplete rim in group II. These MRI manifestations could be proven histologically. In this study, tissue components after RFA could be characterized with discernable contrasts by necrosis-avid contrast agent (NACA)-enhanced MRI, especially at delayed phase. This approach may prove useful for defining the ablated area and identifying residual tumor after RFA.

Animals↗

Electrodes and multiple electrode systems for radio frequency ablation: a proposal for updated terminology.

OBJECTIVE: Research on technology for soft tissue radio frequency (RF) ablation is ever advancing. A recent proposal to standardize terminology of RF electrodes only deals with the most frequently used commercial electrodes. The aim of this study was to develop a logical, versatile, and unequivocal terminology to describe present and future RF electrodes and multiple electrode systems. MATERIALS AND METHODS: We have carried out a PubMed search for the period from January 1st 1990 to July 1st 2004 in seven languages and contacted the six major companies that produce commercial RF electrodes for use in the liver. In a first step, names have been defined for the five existing basic designs of single-shaft electrode. These names had to be unequivocal, descriptive of the electrode's main working principle and as short as possible. In a second step, these basic names have been used as building blocks to describe the single-shaft electrodes in combination designs. In a third step, using the same principles, a logical terminology has been developed for multiple electrode systems, defined as the combined use of more than one single-shaft RF electrode. RESULTS: Five basic electrode designs were identified and defined: plain, cooled, expandable, wet, and bipolar electrodes. Combination designs included cooled-wet, expandable-wet, bipolar-wet, bipolar-cooled, bipolar-expandable, and bipolar-cooled-wet electrodes. Multiple electrode systems could be characterized by describing several features: the number of electrodes that were used (dual, triple, etc.), the electric mode (monopolar or bipolar), the activation mode (consecutive, simultaneous or switching), the site of the inserted electrodes (monofocal or multifocal), and the type of single-shaft electrodes that were used. CONCLUSION: In this terminology, the naming ofthe basic electrode designs has been based on objective criteria. The short and unequivocal names of the basic designs can easily be combined to describe current and future combination electrodes. This terminology provides an exact and complete description of the versatile novel multiple electrode systems.

Catheter Ablation↗

Computer-aided detection of colonic polyps using low-dose CT acquisitions.

RATIONALE AND OBJECTIVES: This report proposes an alternative method for the automatic detection of colonic polyps that is robust enough to be directly applicable on low-dose computed tomographic data. MATERIALS AND METHODS: The polyp modeling process takes into account both the gray-level appearance of polyps (intensity profiles) and their geometry (extended Gaussian images). Spherical harmonic decompositions are used for comparison purposes, allowing fast estimation of the similarity between a candidate and a set of previously computed models. Starting from the original raw data (acquired at 55 mA), five patient data sets (prone and supine scans) are reconstructed at different dose levels (to 5 mA) by using different kernel filters, slice overlaps, and increments. Additionally, the efficacy of applying an edge-preserving smoothing filter before detection is assessed. RESULTS: Although image quality decreases when decreasing acquisition milliamperes, all polyps greater than 6 mm are detected successfully, even at 15 mA. Although not important at high doses, smoothing improves detection results for ultra-low-dose (tube current<15 mA) data. CONCLUSION: The advantage of low-dose scans is a significant decrease in effective dose from 4.93 to 1.61 mSv while retaining high detection values, particularly important when thinking of population screening.

Algorithms↗

The use of carbon dioxide wedged hepatic venography to identify the portal vein: comparison with direct catheter portography with iodinated contrast medium and analysis of predictive factors influencing level of opacification.

PURPOSE: This study was conducted to assess the value of wedged hepatic venography (WHV) with CO(2) as a contrast agent for identification of the portal venous system in patients with cirrhosis. Additionally, the predictive value of several parameters that potentially influence the level of portal vein opacification by CO(2) WHV was analyzed. MATERIALS AND METHODS: In 163 patients, CO(2) WHV was performed before transjugular intrahepatic portosystemic shunt creation to opacify and map the portal vein for subsequent targeting by intrahepatic puncture technique. Concordance between CO(2) WHV and direct catheter portography with iodinated contrast medium was assessed by analysis of sensitivity parameters. Additionally, analysis of factors potentially influencing the opacification of the portal vein with use of CO(2) WHV was assessed. RESULTS: CO(2) WHV was successfully performed in all 163 patients. In three patients (1.8%), CO(2) extravasation was noted, but without any clinical consequence. Sensitivity rates of CO(2) WHV for opacification of the right and left portal veins and the portal main trunk were 93.83% and 68.52%, respectively. Positive predictive factors (P < .05, Wilcoxon two-sample test) were high portosystemic gradient, spontaneous splenorenal shunt, esophageal varices, and reversed portal flow. One negative predictive factor was a patent umbilical vein. CONCLUSIONS: CO(2) WHV is safe, highly efficient, and reliable in the identification of the right and left portal veins. CO(2) WHV is clearly less effective in opacifying the entire portal main trunk. With use of CO(2) WHV, the portal venous system is most distinctly opacified in patients presenting with a high portosystemic gradient, a spontaneous splenorenal shunt, esophageal varices, and reversed portal flow.

Adult↗

Effect of vascular targeting agent in rat tumor model: dynamic contrast-enhanced versus diffusion-weighted MR imaging.

PURPOSE: To compare dynamic contrast material-enhanced magnetic resonance (MR) imaging and diffusion-weighted MR imaging for noninvasive evaluation of early and late effects of a vascular targeting agent in a rat tumor model. MATERIALS AND METHODS: The study protocol was approved by the local ethics committee for animal care and use. Thirteen rats with one rhabdomyosarcoma in each flank (26 tumors) underwent dynamic contrast-enhanced imaging and diffusion-weighted echo-planar imaging in a 1.5-T MR unit before intraperitoneal injection of combretastatin A4 phosphate and at early (1 and 6 hours) and later (2 and 9 days) follow-up examinations after the injection. Histopathologic examination was performed at each time point. The apparent diffusion coefficient (ADC) of each tumor was calculated separately on the basis of diffusion-weighted images obtained with low b gradient values (ADC(low); b = 0, 50, and 100 sec/mm(2)) and high b gradient values (ADC(high); b = 500, 750, and 1000 sec/mm(2)). The difference between ADC(low) and ADC(high) was used as a surrogate measure of tissue perfusion (ADC(low) - ADC(high) = ADC(perf)). From the dynamic contrast-enhanced MR images, the volume transfer constant k and the initial slope of the contrast enhancement-time curve were calculated. For statistical analyses, a paired two-tailed Student t test and linear regression analysis were used. RESULTS: Early after administration of combretastatin, all perfusion-related parameters (k, initial slope, and ADC(perf)) decreased significantly (P < .001); at 9 days after combretastatin administration, they increased significantly (P < .001). Changes in ADC(perf) were correlated with changes in k (R(2) = 0.46, P < .001) and the initial slope (R(2) = 0.67, P < .001). CONCLUSION: Both dynamic contrast-enhanced MR imaging and diffusion-weighted MR imaging allow monitoring of perfusion changes induced by vascular targeting agents in tumors. Diffusion-weighted imaging provides additional information about intratumoral cell viability versus necrosis after administration of combretastatin.

Animals↗

Magnetic resonance imaging study of the level of termination of the conus medullaris and the thecal sac: influence of age and gender.

STUDY DESIGN: Sequential study of magnetic resonance imaging (MRI) of the spine for assessing the level of termination of the conus medullaris (CMT) and thecal sac (TST). OBJECTIVES: To determine the variation in CMT and the TST as a function of age and gender in an adult population without spinal deformity and to investigate the relationship between CMT and TST. SUMMARY OF BACKGROUND DATA: It is generally accepted that the conus medullaris terminates in the lower third of L1; however, a wide range of values has been reported in cadaver studies as well as in MRI studies during life. There have been only a few reports on the influence of gender on the CMT, and the influence of age has not been studied at all. There have been few studies on the range of termination of the thecal sac, and the influence of age and gender remain unexplored. METHODS: We reviewed the 3-mm sagittal MR images of 635 patients, including 297 women and 338 men, with a mean age of 49.43 years. The CMT and TST were located in relation to spinal levels and assigned numerical values ranging from 0 to 13. Parametric and nonparametric statistical tests were used for the data analysis. RESULTS: Mean CMT was at the level of the middle third of L1. The range span extended from the lower third of Th11 to the upper third of L3. The CMT displayed a small but significant positive correlation with age and with gender. Mean TST was at the level of the upper third of S2. The range extended from the lower third of L3 to the upper third of S5. The TST was not affected by gender, but age had an effect on TST. CONCLUSIONS: The CMT and TST displayed a wide range of values in our study. We detected small but systematic influences of gender and age on CMT and of age on TST, as well as a positive correlation between CMT and TST. These effects are small in amplitude, but they met all the criteria for statistical significance and have practical value for clinicians, as well as theoretical value for the medical and biologic community.

Adolescent↗

Passive somatosensory discrimination tasks in healthy volunteers: differential networks involved in familiar versus unfamiliar shape and length discrimination.

Somatosensory discrimination of unseen objects relies on processing of proprioceptive and tactile information to detect spatial features, such as shape or length, as acquired by exploratory finger movements. This ability can be impaired after stroke, because of somatosensory-motor deficits. Passive somatosensory discrimination tasks are therefore used in therapy to improve motor function. Whereas the neural correlates of active discrimination have been addressed repeatedly, little is known about the neural networks activated during passive discrimination of somatosensory information. In the present study, we applied functional magnetic resonance imaging (fMRI) while the right index finger of ten healthy subjects was passively moved along various shapes and lengths by an fMRI compatible robot. Comparing discriminating versus non-discriminating passive movements, we identified a bilateral parieto-frontal network, including the precuneus, superior parietal gyrus, rostral intraparietal sulcus, and supramarginal gyrus as well as the supplementary motor area (SMA), dorsal premotor (PMd), and ventral premotor (PMv) areas. Additionally, we compared the discrimination of different spatial features, i.e., discrimination of length versus familiar (rectangles or triangles) and unfamiliar geometric shapes (arbitrary quadrilaterals). Length discrimination activated mainly medially located superior parietal and PMd circuits whereas discrimination of familiar geometric shapes activated more laterally located inferior parietal and PMv regions. These differential parieto-frontal circuits provide new insights into the neural basis of extracting spatial features from somatosensory input and suggest that different passive discrimination tasks could be used for lesion-specific training following stroke.

Acoustic Stimulation↗

Electrodes and multiple electrode systems for radiofrequency ablation: a proposal for updated terminology.

Research on technology for soft tissue radiofrequency (RF) ablation is ever advancing. A recent proposal to standardise terminology of RF electrodes only deals with the most frequently used commercial electrodes. The aim of this study was to develop a logical, versatile and unequivocal terminology to describe present and future RF electrodes and multiple electrode systems. We have carried out a PubMed search for the period from January 1 1990 to July 1 2004 in seven languages and contacted the six major companies that produce commercial RF electrodes for use in clinic. In a first step, names have been defined for the five existing basic designs of single-shaft electrode. These names had to be unequivocal, descriptive of the electrode's main working principle and as short as possible. In a second step, these basic names have been used as building blocks to describe the single-shaft electrodes in combination designs. In a third step, using the same principles, a logical terminology has been developed for multiple electrode systems, defined as the combined use of more than one single-shaft RF electrode. Five basic electrode designs were identified and defined: plain, cooled, expandable, wet and bipolar electrodes. Combination designs included cooled-wet, expandable-wet, bipolar-wet, bipolar-cooled, bipolar-expandable and bipolar-cooled-wet electrodes. Multiple electrode systems could be characterised by describing several features: the number of electrodes that were used (dual, triple, ...), the electric mode (monopolar or bipolar), the activation mode (consecutive, simultaneous or switching), the site of the inserted electrodes (monofocal or multifocal), and the type of single shaft electrodes that were used. In this terminology, the naming of the basic electrode designs has been based on objective criteria. The short and unequivocal names of the basic designs can easily be combined to describe current and future combination electrodes. This terminology provides an exact and complete description of the versatile novel multiple electrode systems.

Catheter Ablation↗

Dynamic susceptibility contrast-enhanced perfusion MR imaging at 1.5 T predicts final infarct size in a rat stroke model.

The purpose of the present animal experiment was to determine whether source images from dynamic susceptibility contrast-enhanced perfusion weighted imaging (DSC-PWI) at a 1.5T MR scanner, performed early after photochemically induced thrombosis (PIT) of cerebral middle artery (MCA), is feasible to predict final cerebral infarct size in a rat stroke model. Fifteen rats were subjected to PIT of proximal MCA. T2 weighted imaging (T2WI), diffusion-weighted imaging (DWI), and contrast-enhanced PWI were obtained at 1 h and 24 h after MCA occlusion. The relative lesion size (RLS) was defined as lesion volume/brain volume x 100% and measured for MR images, and compared with the final RLS on the gold standard triphenyl tetrazolium chloride (TTC) staining at 24 h. One hour after MCA occlusion, the RLS with DSC-PWI was 24.9 +/- 6.3%, which was significantly larger than 17.6 +/- 4.8% with DWI (P < 0.01). At 24 h, the final RLS on TTC was 24.3 +/- 4.8%, which was comparable to 25.1 +/- 3.5%, 24.6 +/- 3.6% and 27.9 +/- 6.8% with T2WI, DWI and DSC-PWI respectively (P > 0.05). The fact that at 1 h after MCA occlusion only the displayed perfusion deficit was similar to the final infarct size on TTC (P > 0.05) suggests that early source images from DSC-PWI at 1.5T MR scanner is feasible to noninvasively predict the final infarct size in rat models of stroke.

Animals↗

Computer aided detection for low-dose CT colonography.

The paper describes a method for automatic detection of colonic polyps, robust enough to be directly applied to low-dose CT colonographic datasets. Polyps are modeled using gray level intensity profiles and extended Gaussian images. Spherical harmonic decompositions ensure an easy comparison between a polyp candidate and a set of polypoid models, found in a previously built database. The detection sensitivity and specificity values are evaluated at different dose levels. Starting from the original raw-data (acquired at 55mAs), 5 patient datasets (prone and supine scans) are reconstructed at different dose levels (down to 5mAs), using different kernel filters and slice increments. Although the image quality decreases when lowering the acquisition mAs, all polyps above 6mm are successfully detected even at 15 mAs. Accordingly the effective dose can be reduced from 4.93mSv to 1.61 mSv, without affecting detection capabilities, particularly important when thinking of population screening.

Algorithms↗

Plaque and stent artifact reduction in subtraction CT angiography using nonrigid registration and a volume penalty.

Computed tomography angiography (CTA) is an established tool for vessel imaging. Yet, high-intense structures in the contrast image can seriously hamper luminal visualisation. This can be solved by subtraction CTA, where a native image is subtracted from the contrast image. However, patient and organ motion limit the application of this technique. Within this paper, a fully automated intensity-based nonrigid 3D registration algorithm for subtraction CT angiography is presented, using a penalty term to avoid volume change during registration. Visual and automated validation on four clinical datasets clearly show that the algorithm strongly reduces motion artifacts in subtraction CTA. With our method, 39% to 99% of the artifacts disappear, also those caused by minimal displacement of stents or calcified plaques. This results in a better visualisation of the vessel lumen, also of the smaller vessels, allowing a faster and more accurate inspection of the whole vascular structure, especially in case of stenosis.

Algorithms↗

Necrosis avid contrast agents: functional similarity versus structural diversity.

Two categories of necrosis-avid contrast agents (NACAs), namely porphyrin- and nonporphyrin-based complexes, have thus far been discovered as necrosis-targeting markers for noninvasive magnetic resonance imaging (MRI) identification of acute myocardial infarction, assessment of tissue or organ viability, and therapeutic evaluation after interventional therapies. In addition to necrosis labeling, other less-specific functions, such as first-pass perfusion, blood pool contrast effect, hepatobiliary contrast enhancement (CE), adrenal and spleen CE, and renal functional imaging, also are demonstrated with NACAs. Despite various investigations with a collection of clues in favor of certain hypotheses, the mechanisms of such a unique targetability for NACAs still remain to be elucidated. However, a few things have become clear that porphyrin-like structures are not necessary for necrosis avidity and the albumin binding is not the supposed driving force but only a parallel nonspecific feature shared by both NACAs and non-NACA substances. Although the research and development of NACAs still remain in preclinical stage at a relatively small scale, their significance rests upon striking enhancement effects, which may warrant their eventual versatile clinical applications. The present review article is intended to summarize the cumulated facts about the evolving research on this topic, to demonstrate experimental observations for better understanding of the mechanisms, to trigger broader public interests and more intensive research activities, and to advocate, toward both academics and industries, further promotion of preclinical and clinical development of this unique and promising class of contrast agents.

Animals↗