PubMed Health⌕ Search

Biomedical subjects

Guy Mareels

Publications and source records attributed to Guy Mareels.

2 recordsLinked to original sources

Three-dimensional numerical modeling and computational fluid dynamics simulations to analyze and improve oxygen availability in the AMC bioartificial liver.

A numerical model to investigate fluid flow and oxygen (O(2)) transport and consumption in the AMC-Bioartificial Liver (AMC-BAL) was developed and applied to two representative micro models of the AMC-BAL with two different gas capillary patterns, each combined with two proposed hepatocyte distributions. Parameter studies were performed on each configuration to gain insight in fluid flow, shear stress distribution and oxygen availability in the AMC-BAL. We assessed the function of the internal oxygenator, the effect of changes in hepatocyte oxygen consumption parameters in time and the effect of the change from an experimental to a clinical setting. In addition, different methodologies were studied to improve cellular oxygen availability, i.e. external oxygenation of culture medium, culture medium flow rate, culture gas oxygen content (pO(2)) and the number of oxygenation capillaries. Standard operating conditions did not adequately provide all hepatocytes in the AMC-BAL with sufficient oxygen to maintain O(2) consumption at minimally 90% of maximal uptake rate. Cellular oxygen availability was optimized by increasing the number of gas capillaries and pO(2) of the oxygenation gas by a factor two. Pressure drop over the AMC-BAL and maximal shear stresses were low and not considered to be harmful. This information can be used to increase cellular efficiency and may ultimately lead to a more productive AMC-BAL.

Cell Culture Techniques↗

Computational fluid dynamics-analysis of the Niagara hemodialysis catheter in a right heart model.

Central venous catheters are widely used as a hemoaccess method for dialysis therapy. In this study, the performance parameters (velocities, pressure drop, shear rates, access recirculation) of the Niagara catheter are analyzed using computational fluid dynamics. Side holes are left open, closed, or reduced in size to assess the influence of this design feature. Initially the catheter is inserted in a tube which represents the vena cava. In the "arterial" luminal tip, wall shear rates over 20,000 s(-1) are common and peaks attain 55,000 s(-1) at a 300 mL/min blood flow rate. The presence of side holes appears to affect the location but not the level of these elevated shear rates. Halving their diameter causes elevated shear rates to appear in a more extended region with peaks up to 80,000 s(-1). Simulated recirculation percentage is nil in normal catheter use, but attains 30% with reversed catheter connections. The results of the tube model are compared to those of an anatomically realistic right atrium model, which was three-dimensionally reconstructed. It is concluded that most catheter's specific hemodynamic properties can be deduced from the tube model.

Atrial Function, Right↗