PubMed Health⌕ Search

Biomedical subjects

Gwo-Bin Lee

Publications and source records attributed to Gwo-Bin Lee.

6 recordsLinked to original sources

Liquid biopsy-based detection of circulating and exfoliated cholangiocarcinoma tumor cells from blood and bile using heparan sulfate octasaccharides on integrated microfluidic systems.

Early diagnosis of cholangiocarcinoma (CCA) remains challenging because existing diagnostic approaches often lack sufficient sensitivity for reliable detection of early-stage disease. Circulating tumor cells (CTCs) in blood and exfoliated tumor cells (ETCs) in bile represent valuable targets for liquid biopsy-based detection; however, their low abundance and the complexity of clinical sample analysis pose substantial technical challenges for reliable enrichment and identification. Herein, we present a reproducible workflow for isolating and identifying CCA tumor cells from blood for CTCs and bile for ETCs using synthetic cell-surface heparan sulfate (HS) octasaccharide-functionalized magnetic beads (MBs) on integrated microfluidic systems. The method combined sample pre-processing, magnetic bead-based enrichment, controlled low-shear mixing and immunofluorescence-based identification into a unified workflow compatible with distinct clinical sample types. Key operational parameters, including MB concentration, mixing frequency, and pressure settings, were detailed to facilitate consistent performance. Using this workflow, tumor cell capture rates of approximately 70% in bile (for ETCs) and blood (for CTCs) were achieved, with a total processing time of 60-90 min per sample under clinically relevant low-abundance conditions. The platform enables reliable detection of as few as 1 tumor cell per mL of blood or bile. This method provides a practical and adaptable strategy for glycosaminoglycan-mediated liquid biopsy applications and may be extended to other tumor-cell enrichment workflows involving heterogeneous cell-surface interactions.

Humans↗

Electrokinetic focusing injection methods on microfluidic devices.

This paper presents an experimental and numerical investigation into electrokinetic focusing injection on microfluidic chips. The valving characteristics on microfluidic devices are controlled through appropriate manipulations of the electric potential strengths during the sample loading and dispensing steps. The present study also addresses the design and testing of various injection systems used to deliver a sample plug. A novel double-cross injection microfluidic chip is fabricated, which employs electrokinetic focusing to deliver sample plugs of variable volume. The proposed design combines several functions of traditional sample plug injection systems on a single microfluidic chip. The injection technique uses an unique sequence of loading steps with different electric potential distributions and magnitudes within the various channels to effectuate a virtual valve.

Journal Article↗

Multiple injection techniques for microfluidic sample handling.

This paper presents an experimental and numerical investigation into electrokinetic focusing flow injection for bioanalytical applications on 1 x N (i.e., 1 sample inlet port and N outlet ports) and M x N (i.e., M sample inlet ports and N outlet ports) microfluidic chips. A novel device is presented which integrates two important microfluidic phenomena, namely electrokinetic focusing and valveless flow switching within multiported microchannels. The study proposes a voltage control model which achieves electrokinetic focusing in a prefocusing sample injection system and which allows the volume of the sample to be controlled. Using the developed methods, the study shows how the sample may be prefocused electrokinetically into a narrow stream prior to being injected continuously into specified outlet ports. The microfluidic chips presented within this paper possess an exciting potential for use in a variety of techniques, including high-throughput chemical analysis, cell fusion, fraction collection, fast sample mixing, and many other applications within the micrototalanalysis systems field.

Automation↗

Flow-through sampling for electrophoresis-based microchips and their applications for protein analysis.

This work presents a model behind the operation of a flow-through sampling chip and its application for immunoseparation, as well as its integration with a wash/elution bed for protein purification, concentration, and detection. This device used hydrodynamic pressure to drive the sample flow, and a gating voltage was applied to the electrophoretic channel on the microchip to control the sample loading for the separation and to inhibit sample leakage. The deduced model indicates that the critical gating voltage (VC) that is defined as the minimum gating voltage applied to the microchip for sampling is a function of the pump flow rate, the configuration of the microchannel on the chip, and the electroosmosis of the buffer solution. It was found that the theoretical V(C) values calculated from the measured electroosmotic mobilities and flow split ratios were comparable to those experimentally obtained from two microchips with different sampling channel sizes. This had an error percentage ranging from 1 to 20%. Because the hydrodynamic flow is insensitive to electrophoretic mobility, this electrophoresis-based microchip device was free of injection bias due to different ionic strength and electrophoretic mobility in the sample. Additionally, the usefulness of this device was demonstrated for the study of affinity interactions. Mixtures of Cy5-labeled bovine serum albumin (Cy5-BSA) and anti-BSA in various proportions were introduced into the microchip via a syringe pump, and the immunocomplex was electrophoretically separated from the free Cy5-BSA on the microchip. Based on the relative intensity of the free and complex BSA, the binding constant of BSA and anti-BSA was estimated as 3.3 x 10(7) M(-1). Furthermore, a C18 microcartridge (20 microL) was connected to the hydrodynamic inlet of the microchip. Using this device, the wash/elution step can be integrated on-line with the electrophoretic separation and detection on the microchip. Results show that the calibration curve of Cy5-BSA obtained from this integrated device has an R2 value greater than 0.99 and a minimum of quantitation at approximately 10 ng. This direct sampling method is another means of subfractionation, resulting in a relatively greater concentration factor than the average concentration of the whole fraction. Moreover, the electrical field-free bed ensures that the protein interaction will not be affected by the electric field during the wash/elution step.

Algorithms↗

Analysis of geometry effects on band spreading of microchip electrophoresis.

The geometry and the flow field conditions in the separation microchannel of an electrophoresis chip system may have important impact on the system's separation efficiency. Understanding the geometry effect on the flow field physics in the separation microchannel is beneficial to the design or operation of an electrophoresis system. The turns in a microfabricated separation microchannel generally results in degraded separation quality. To avoid this limitation, channels are constructed with different types of turns to determine the optimum design that minimizes turn-induced band broadening. We have designed and tested various geometric bend ratios to greatly reduce this so-called "racetrack" effect. The effects of the separation channel geometry, fluid velocity profile and bend ratio on the band distribution in the detection area are discussed. Results show that the folded square U-shaped channel is better for miniaturization and simplification. The band tilting was corrected and the racetrack effect reduced in the detection area when the bend ratio is 4:1. The detection time obtained from the present numerical solution matches very well with the experimental data.

DNA↗

Automation for continuous analysis on microchip electrophoresis using flow-through sampling.

Automation of electrophoretic microchips for sequential analysis of different samples is demonstrated. This system used an autosampler, which was on-line connected to the microchip and the whole process including sample loading and injection, analysis and data acquisition as well as washing were all automated. Rhodamin B at different concentrations was first loaded into a hydrodynamic flow stream by an autosampler, delivered to the microchip, and then sequentially injected into the electrophoretic microchannel for analysis and detection. Automation was achieved by running two independent programs, one for sample loading by an autosampler and the other one for electrophoretic injection by voltage switching, on the same computer. Using this sampling chip, each loaded volume (0.2-1 microL) can be injected for dozens of electrophoretic analyses (1-10 nL for each injection). The variances caused by the external connections, which did not affect the electrophoretic analysis but would cause band broadening of the loaded sample in the hydrodynamic flow stream, were theoretically deduced. Results indicate that the dead volume (approximately 300 nL) due to the connection fitting on the chip could lead to dilution of the loaded sample by a factor of one when 0.2 microL of sample was loaded. Such a design allows sequential analysis of a series of samples while the running buffer is continuously pumped into the connection capillary as well as microchannels for washing between two loaded samples to minimize cross contamination without human intervention. Using this sampling chip, the required sample amount and handling time can be greatly reduced compared to the manual method.

Automation↗