PubMed Health⌕ Search

Biomedical subjects

Gwynedd E Pickett

Publications and source records attributed to Gwynedd E Pickett.

9 recordsLinked to original sources

Epidemiology of traumatic spinal cord injury in Canada.

STUDY DESIGN: Retrospective review. OBJECTIVE: To describe the incidence, clinical features, and treatment of traumatic spinal cord injury (SCI) treated at a Canadian tertiary care center. SUMMARY OF BACKGROUND DATA: Understanding the current epidemiology of acute traumatic SCI is essential for public resource allocation and primary prevention. Recent reports suggest that the mean age of patients with SCI may be increasing. METHODS: We retrospectively reviewed hospital records on all patients with traumatic SCI between January 1997 and June 2001 (n = 151). Variables assessed included age, gender, length of hospitalization, type and mechanism of injury, associated spinal fractures, neurologic deficit, and treatment. RESULTS: Annual age-adjusted incidence rates were 42.4 per million for adults aged 15-64 years, and 51.4 per million for those 65 years and older. Motor vehicle accidents accounted for 35% of SCI. Falls were responsible for 63% of SCI among patients older than 65 years and for 31% of injuries overall. Cervical SCI was most common, particularly in the elderly, and was associated with fracture in only 56% of cases. Thoracic and lumbar SCI were associated with spinal fractures in 100% and 85% of cases, respectively. In-hospital mortality was 8%. Mortality was significantly higher among the elderly. Treatment of thoracic and lumbar fractures associated with SCI was predominantly surgical, whereas cervical fractures were equally likely to be treated with external immobilization alone or with surgery. CONCLUSION: A large proportion of injuries was seen among older adults, predominantly as a result of falls. Prevention programs should expand their focus to include home safety and avoidance of falls in the elderly.

Accidental Falls↗

Complications with cervical arthroplasty.

OBJECT: Spinal arthroplasty is becoming more widely performed in the treatment of degenerative cervical disc disease. Although this new technology may offer benefits over arthrodesis, it also requires that the surgeon acquire new operative techniques, and new potential complications are introduced. To determine the incidence and distribution of perioperative complications, the authors analyzed their early data obtained in a series of patients treated with the Bryan Cervical Disc prosthesis. METHODS: The authors prospectively recorded operative data, complications, and clinical and radiographic outcome data in all patients treated with Bryan prosthesis-based arthroplasty at two tertiary care centers since 2001. Patients underwent standard anterior cervical discectomy followed by one- to three-level arthroplasty. Ninety-six discs were implanted in 74 patients. The perioperative complication rate was 6.2% per treated level. In one patient a retropharyngeal hematoma developed, requiring evacuation. Neurological worsening occurred in three patients. Intraoperative migration of the prosthesis was observed in one two-level case, whereas delayed migration occurred in one patient with postoperative segmental kyphosis. In another patient with severe postoperative segmental kyphosis, revision was required with a customized lordotic prosthesis. Heterotopic ossification and spontaneous fusion occurred in two cases; motion was preserved in the remaining 94 prostheses. Partial dislocation of the prosthesis in extension occurred in one patient with preoperative segmental hypermobility, the first reported failure of a Bryan prosthesis. Twenty-five percent of patients reported neck and shoulder pain during the late follow-up period. There was a trend toward increased kyphosis of the C2-7 curvature postoperatively. CONCLUSIONS: The Bryan prosthesis was effective in maintaining spinal motion. Major perioperative and device-related complications were infrequent.

Adult↗

Kinematic analysis of the cervical spine following implantation of an artificial cervical disc.

STUDY DESIGN: Prospective cohort study. OBJECTIVE: To assess the biomechanical profile of the cervical spine following cervical arthroplasty. SUMMARY OF BACKGROUND DATA: Spinal arthroplasty offers the promise of maintaining functional spinal motion, thereby potentially avoiding adjacent segment disease. Disc replacement may become the next gold standard for the treatment of degenerative cervical spine disease, and must be studied rigorously to ensure in vivo efficacy and safety. METHODS: A total of 20 patients underwent single or 2-level implantation of the Bryan artificial cervical disc (Medtronic Sofamor Danek, Memphis TN) for treatment of cervical degenerative disc disease producing radiculopathy and/or myelopathy. Lateral neutral, flexion, and extension cervical radiographs were obtained before surgery and at intervals up to 24 months after surgery. Kinematic parameters, including sagittal rotation, horizontal translation, change in disc height, and center of rotation (COR), were assessed for each spinal level using quantitative motion analysis software. RESULTS: Motion was preserved in the operated spinal segments (mean range of motion 7.8 degrees) up to 24 months following surgery. The relative contribution of each spinal segment to overall spinal sagittal rotation differed depending on whether the disc was placed at C5-C6 or C6-C7. Overall cervical motion (C2-C7) was moderately but significantly increased during late follow-up. Sagittal rotation, anterior and posterior disc height, translation, and COR coordinates did not change significantly following surgery. The COR was most frequently located posterior and inferior to the center of the disc space. CONCLUSIONS: The Bryan artificial cervical disc provided in vivo functional spinal motion at the operated level, reproducing the preoperative kinematics of the spondylotic disc.

Arthroplasty, Replacement↗

Cervical total disc replacement, part two: clinical results.

This article focuses on the clinical results of three prostheses (the Bryan Cervical Disc, the Bristol Disc, and the ProDisc-C) for cervical total disc replacement. Background on the development, design, and biomechanical characteristics of each prosthesis is given and surgical indications and clinical results are summarized and analyzed.

Adult↗

Percutaneous retrogasserian glycerol rhizotomy in the treatment of tic douloureux associated with multiple sclerosis.

OBJECTIVE: Patients with multiple sclerosis (MS) have a relatively high incidence of tic douloureux (TD) and often do not tolerate medical therapy well. The minimally invasive nature of percutaneous retrogasserian glycerol rhizotomy (PRGR) renders it ideal for first-line surgical treatment of TD. We sought to ascertain the benefits of PRGR in patients with MS and to determine whether hypalgesia after PRGR correlates with efficacy. METHODS: We assessed 97 glycerol procedures performed in 53 patients followed prospectively for treatment of TD associated with MS. Factors assessed included degree of pain relief, postoperative hypalgesia, procedural morbidity, medication use, time to pain recurrence, and number and type of subsequent procedures. RESULTS: Complete pain relief was obtained in 78% of patients after the initial glycerol injection, and partial relief was obtained in 13% of patients. Long-term follow-up (mean, 81 mo) demonstrated a recurrence rate of 59%, with a mean time to recurrence of 17 months. Actuarial recurrence rates were 50% at 12 months and 60% at 24 months. Twenty-four patients underwent a second or subsequent PRGR for recurrent pain and achieved similar rates of pain relief and time to recurrence. Facial sensory loss was associated with a higher likelihood of pain relief (P < 0.05), with longer time to pain recurrence (P < 0.05), and with decreased use of medication after surgery (P < 0.01.) CONCLUSION: PRGR is an effective, low-morbidity surgical procedure in the management of TD complicating MS. The presence of facial sensory loss after PRGR is associated with prolonged efficacy.

Adult↗

Effects of a cervical disc prosthesis on segmental and cervical spine alignment.

OBJECT: Cervical arthroplasty offers the promise of maintaining motion of the functional spinal unit (FSU) after anterior cervical discectomy. The impact of cervical arthroplasty on sagittal alignment of the FSU needs to be addressed, together with its effect on overall sagittal balance of the cervical spine. METHODS: The authors prospectively reviewed radiographic and clinical outcomes in 14 patients who received the Bryan Cervical Disc prosthesis (Medtronic Sofamor Danek, Memphis, TN), for whom early (< 6 months) and late (6-24 months) follow-up data were available. Static and dynamic radiographs were measured by hand and computer to determine the angles formed by the endplates of the natural disc preoperatively, those formed by the shells of the implanted prosthesis, the angle of the FSU, and the C2-7 Cobb angle. The range of motion (ROM) was also determined radiographically, whereas clinical outcomes were assessed using the Neck Disability Index (NDI), and Short Form-36 (SF-36) questionnaires. The ROM was preserved following surgery, with a mean preoperative sagittal rotation angle of 8.96 degrees , which was not significantly different from the late postoperative value of 8.25 degrees . When compared with the preoperative disc space angle, the shell endplate angle in the neutral position became kyphotic in the early and late postoperative periods (mean change -3.8 degrees in the late follow-up period; p = 0.0035). The FSU angles also became significantly more kyphotic postoperatively, with a mean change of -6 degrees (p = 0.0006). The Cobb angles varied widely preoperatively and did not change significantly after surgery. There was no statistical correlation between the NDI and SF-36 outcomes and cervical kyphosis. CONCLUSIONS: Cervical arthroplasty preserves motion of the FSU. Both the endplate angle of the treated disc space and the angle of the FSU became kyphotic after insertion of the Bryan prosthesis. The overall sagittal balance of the cervical spine, however, was preserved.

Adult↗

Early clinical and biomechanical results following cervical arthroplasty.

OBJECT: Spinal arthroplasty may become the next gold standard for the treatment of degenerative cervical spine disease. This new modality must be studied rigorously to ensure in vivo efficacy and safety. The authors review the preliminary clinical experience and radiographic outcomes following insertion of the Bryan Cervical Disc Prosthesis (Medtronic Sofamor Danek, Memphis, TN). METHODS: This prospective cohort study included 26 patients undergoing single- or two-level implantation of the Bryan artificial cervical disc for treatment of cervical degenerative disc disease resulting in radiculopathy and/or myelopathy. Radiographic and clinical assessments were made preoperatively 1.5, 3 months, and at 6, 12, and up to 24 months postoperatively. The Neck Disability Index (NDI) and Short Form-36 (SF-36) questionnaires were used to assess pain and functional outcomes. Segmental sagittal rotation from C2-3 to C6-7 was measured using quantitative motion analysis software. A total of 30 Bryan discs were placed in 26 patients. A single-level procedure was performed in 22 patients and a two-level procedure in the other four. Follow-up duration ranged from 1.5 to 27 months, with a mean duration of 12.3 months. A statistically significant improvement in the mean NDI scores was seen between pre- and late postoperative follow-up evaluations. A trend toward improvement in the SF-36 physical component was also found. Motion was preserved in the treated spinal segments (mean range of motion 7.8 degrees ) for up to 24 months postsurgery. The relative contribution of each segment to overall spinal sagittal rotation differed depending on whether the disc was placed at C5-6 or C6-7. Overall cervical motion (C2-7) was moderately increased on late follow-up evaluations. CONCLUSIONS: The Bryan artificial cervical disc provided in vivo functional spinal motion at the treated level. Overall cervical spinal motion was not significantly altered. Sagittal rotation did not change significantly at any level after surgery.

Adult↗

Controversies in cervical discectomy and fusion: practice patterns among Canadian surgeons.

OBJECTIVE: Optimal fusion technique and peri-operative management of patients undergoing anterior cervical discectomy (ACD) is unclear. We document current practice patterns among Canadian spinal surgeons regarding the surgical management of single level degenerative cervical spondylosis. METHODS: We conducted a web-based survey of neurosurgeons and spinal orthopedic surgeons in Canada. We asked questions pertaining to the management of single level cervical degenerative disc disease causing radiculopathy and/or myelopathy, including frequency of fusion following single-level discectomy, preferred fusion technique, indications and frequency of use of anterior plating, and use of an external cervical orthosis following surgery. Demographic factors assessed included training background, type and length of practice. RESULTS: Sixty respondents indicated that their practice involved at least 5% spine surgery and were included in further analysis. Neurosurgeons comprised 59% of respondents, and orthopedic surgeons 41%. Fusion was employed 93% of the time following ACD; autologous bone was the preferred fusion material, used in 76% of cases. Neurosurgeons employed anterior cervical plates in 42% of anterior cervical discectomy and fusion cases, whereas orthopedic surgeons used them 70% of the time. External cervical orthoses were recommended for 92% of patients without plates and 61% of patients with plates. Surgeons who had been in practice for less than five years were most likely to be performing spinal surgery, using anterior cervical plates, and recommending the postoperative use of cervical orthoses. CONCLUSION: Practice patterns vary among Canadian surgeons, although nearly all employ fusion and many use instrumentation for single-level ACD. Training background, and type and length of practice influence practice habits.

Adult↗

Artificial disc insertion following anterior cervical discectomy.

OBJECTIVE AND IMPORTANCE: Fusion following anterior cervical discectomy has been implicated in the acceleration of degenerative changes in the adjacent spinal segments. Discectomy followed by implantation of an artificial cervical disc maintains the functionality of the spinal unit, while still providing excellent symptomatic relief. We describe our preliminary experience with implantation of the Bryan Cervical Disc System in two cases of single-level cervical disc herniation. CLINICAL PRESENTATION: Two male patients presented with a left C6 radiculopathy, without evidence of myelopathy. Magnetic resonance imaging revealed a disc herniation at C5-6 in both cases. Pre-operative flexion and extension radiographs demonstrated preserved motion at the involved levels. INTERVENTION/TECHNIQUE: Following a standard anterior cervical decompression, precision drilling of the vertebral endplates was carried out using a drill attached to a bed-mounted, gravitationally-referenced retraction frame. An artificial cervical disc, composed of a polyurethane nucleus with titanium endplates, was fitted between the contoured endplates without fixation to the vertebral bodies. No complications were experienced during the insertion of the prosthesis, or in the postoperative course. Both patients experienced immediate postoperative resolution of their radicular pain and were discharged from hospital the following day. At nine months following surgery, both patients continue to have complete relief of radicular symptoms. Postoperative radiographs at six months following surgery confirm accurate placement of the prosthesis and preserved mobility of the functional spinal unit. CONCLUSION: Insertion of the Bryan artificial cervical disc prosthesis following anterior cervical discectomy is a relatively straightforward procedure, which appears to be safe and provides good clinical results, without requiring additional surgical time. Long-term follow-up is required to assess its safety, efficacy, and ability to prevent adjacent segment degeneration.

Adult↗