PubMed Health⌕ Search

Biomedical subjects

H A M Seelen

Publications and source records attributed to H A M Seelen.

6 recordsLinked to original sources

Assessment of upper extremity muscle function in persons with tetraplegia.

The objective was to investigate the actual level of muscle function impairment in tetraplegic persons and, inextricably related to this, the possibilities to compensate function loss using new muscle coalitions. In this cross-sectional group study, 20 persons with a cervical spinal cord injury (SCI) at segmental levels C5C6 or C7C8 and 10 control persons participated. Activity from 21 upper extremity and trunk muscles was recorded during standardised gross upper extremity task performance. No substantial differences in main activation patterns were found between C7C8 and control subjects. In contrast, main activation patterns in C5C6 persons showed an absence of selectivity, which may be explained by the participants activating every controllable muscle in an attempt to perform maximally. In order to identify more intricate differences in muscle activation between control and C7C8 persons a fine motor function task may be necessary. Muscle activation patterns during arm task performance were stable in all three groups.

Adult↗

Measuring change in arm hand skilled performance in persons with a cervical spinal cord injury: responsiveness of the Van Lieshout Test.

OBJECTIVES: To asses whether the Van Lieshout Test (VLT) is responsive to measure changes in arm hand skilled performance (AHSP) over time during active rehabilitation in persons with cervical spinal cord injury (C-SCI) and in different subgroups of persons with C-SCI according to lesion completeness and to lesion level. STUDY DESIGN: Longitudinal cohort study. SETTING: Spinal Cord Injury Units in eight rehabilitation centres across the Netherlands. METHODS: In the present study, data from a national SCI cohort study are used. Data from the VLT, the Grasp Release Test (GRT), the Functional Independence Measure (FIM) and the Quadriplegia Index of Function (QIF) were recorded at three moments during active rehabilitation: at the start of active rehabilitation (t1), 3 months after t1 (t2) and at discharge (t3). Data have been analysed using three responsiveness measures, that is, the standardized response mean, the effect size and comparison of test scores measured at different times. RESULTS: The VLT is responsive for the intervals t1-3, t1-2 and t2-3. The VLT can be used to measure changes in AHSP in persons with a C-SCI with an American Spinal Injury Association Impairment Scale (AIS) A or B score or an AIS C or D score, as well as in persons with a C3-C6 lesion or a C7-T1 lesion. The responsiveness of the VLT is significantly correlated to the GRT, but not to the FIM and the QIF. CONCLUSION: The VLT is responsive in measuring changes in AHSP during rehabilitation in persons with C-SCI.

Activities of Daily Living↗

Measurement properties of the short version of the Van Lieshout test for arm/hand function of persons with tetraplegia after spinal cord injury.

STUDY DESIGN: Two validation studies. OBJECTIVES: To assess the measurement properties of the short version of the Van Lieshout test (VLT-SV), a new test for arm/hand function of persons with tetraplegia after spinal cord injury (SCI). SETTING: Two specialized rehabilitation centres in The Netherlands. METHODS: Study 1 (N=12)--assessment of inter-rater reliability (intraclass correlations (ICC); weighted kappa; Bland-Altman plots). Study 2 (N=55)--assessment of convergent validity by computing Spearman's correlations with the Grasp-Release test (GRT; criterion standard) and with motor level of injury, ASIA impairment scale, international classification for surgery of the hand, and the self-care and transfer scales of the functional independence measure. All statistics were computed separately for the right- and the left-hand scores. RESULTS: Inter-rater reliability was excellent (ICC 0.98 and 0.99). Agreement was independent of the height of the scores and the limits of agreement were +/-0.5 points on a 0-5 scale. Convergent validity was very good with a Spearman correlation of 0.87 and 0.90 between the VLT-SV and the GRT and correlations between 0.35 and 0.85 with the other indicators of arm/hand function. CONCLUSION: The VLT-SV seems a reliable and valid test to assess arm/hand function of persons with tetraplegia after SCI.

Activities of Daily Living↗

Effects of prosthesis alignment on pressure distribution at the stump/socket interface in transtibial amputees during unsupported stance and gait.

OBJECTIVE: To assess the effects of antero-posterior realignment of the prosthesis on pressure distribution at the stump/socket interface in unilateral transtibial amputees during unsupported stance and gait. DESIGN: Cross-sectional group study. SETTING: Outpatient rehabilitation clinic. SUBJECTS: Seventeen unilateral transtibial amputees. INTERVENTION: Antero-posterior prosthesis realignment using 0.5 cm heel or forefoot wedging. MEASURES: Pressure distribution changes at several sites at the stump/socket interface, expressed as peak pressure, peak pressure time, sustained submaximal load (MP80+) and time period of MP80+ (TP80+). RESULTS: During stance, heel wedging led to a 30.4% decrease in mean pressure near the patella tendon and a 40.0% increase near the distal tibia site, whereas forefoot wedging led to a 30.0% decrease in pressure in the tibial end region. Antero-posterior ankle realignment did not lead to significant changes near the fibular head. During gait only heel wedging led to a 11.5% increase in peak pressure in the tibia end region. Mean peak pressure time increased 22.7% using heel wedging and decreased 8.8% using forefoot wedging. MP80+ increased 23.8% in the tibia end region during heel wedging and 17.0% in the subpatellar region during forefoot wedging. CONCLUSIONS: Antero-posterior realignment of the ankle joint led to an inverse loading and unloading of the subpatellar region versus tibial end region. However, results indicate that stump/socket interface pressure during stance seems not to be highly predictive as to pressure behaviour during gait. Ankle joint realignment led to significant differences in temporal sequences of tissue (un-)loading in the subpatellar area during gait.

Amputation, Surgical↗

Evaluation of upper extremity motor function tests in tetraplegics.

OBJECTIVE: To provide an overview of arm-hand function tests useful in tetraplegic subjects. Considerations for selection of an appropriate test are also provided. DATA SOURCES: A Medline literature search was conducted covering the period from 1967 to March 2001. Relevant references cited in the selected papers were also considered, regardless of the year of publication. STUDY SELECTION: This review was restricted to strength tests, functional and ADL tests. Only general tests and tests designed specifically to test tetraplegic persons written in English, or in Dutch were included in the review. RESULTS: Information is provided on four types of strength tests, 10 general and five specific functional tests and eight ADL tests. CONCLUSION: Many tests are available to measure upper extremity motor function in tetraplegics. Selection of a test is at first determined by the outcome value in which the investigator is interested. When the type of outcome value has been determined, the most suitable test has to be selected from the range of available tests. When two tests appear to be equally suitable, the availability of information on psychometric properties of the test when used in tetraplegic patients is a decisive factor. When information on the reliability, validity and sensitivity of a test is missing, it should be gathered before using the test.

Activities of Daily Living↗

Ankle-foot orthosis has limited effect on walking test parameters among patients with peripheral ankle dorsiflexor paresis.

The aim of this study was to determine the relationship between ankle dorsiflexor strength and performances on several walking tests and to determine the effect of ankle-foot orthosis (AFO) use on walking tests. The following tests were used: 10-metre walking test (with and without three stairs), a complex walking task (6-minute walk with cognitive loading) and a subjective evaluation (SIP68 mobility scale and questionnaire). Isometric strength of the ankle dorsiflexors was measured. All walking tests were performed with and without AFO in random order. When relating torque values to walking performances, the highest correlation was found with the "10 metre" and "10 metre with stairs" test (r = -0.51, i.e. an inverse relationship). No threshold in the degree of paresis was found below which walking disability suddenly increased. No significant improvement could be demonstrated from AFO use on the 10-metre tests. Improvement on the 6-minute test was nearly significant (p = 0.06), the questionnaire revealed a positive opinion on AFO use related to overall walking function and effort. Thus, we have to conclude that these walking tests do not aid the clinician in estimating the severity of (progression of) the paresis nor to detect differences in degree of paresis between subjects.

Adult↗