Attenuation correction of PET cardiac data with low-dose average CT in PET/CT.

We proposed a low-dose average computer tomography (ACT) for attenuation correction (AC) of the PET cardiac data in PET/CT. The ACT was obtained from a cine CT scan of over one breath cycle per couch position while the patient was free breathing. We applied this technique on four patients who underwent tumor imaging with 18F-FDG in PET/CT, whose PET data showed high uptake of 18F-FDG in the heart and whose CT and PET data had misregistration. All four patients did not have known myocardiac infarction or ischemia. The patients were injected with 555-740 MBq of 18F-FDG and scanned 1 h after injection. The helical CT (HCT) data were acquired in 16 s for the coverage of 100 cm. The PET acquisition was 3 min per bed of 15 cm. The duration of cine CT acquisition per 2 cm was 5.9 s. We used a fast gantry rotation cycle time of 0.5 s to minimize motion induced reconstruction artifacts in the cine CT images, which were averaged to become the ACT images for AC of the PET data. The radiation dose was about 5 mGy for 5.9 s cine duration. The selection of 5.9 s was based on our analysis of the respiratory signals of 600 patients; 87% of the patients had average breath cycles of less than 6 s and 90% had standard deviations of less than 1 s in the period of breath cycle. In all four patient studies, registrations between the CT and the PET data were improved. An increase of average uptake in the anterior and the lateral walls up to 48% and a decrease of average uptake in the septal and the inferior walls up to 16% with ACT were observed. We also compared ACT and conventional slow scan CT (SSCT) of 4 s duration in one patient study and found ACT was better than SSCT in depicting average respiratory motion and the SSCT images showed motion-induced reconstruction artifacts. In conclusion, low-dose ACT improved registration of the CT and the PET data in the heart region in our study of four patients. ACT was superior than SSCT for depicting average respiration motion in a patient study.

Artifacts↗

Attenuation correction of PET images with respiration-averaged CT images in PET/CT.

UNLABELLED: Attenuation correction (AC) of PET images with helical CT (HCT) in PET/CT matches only the spatial resolution of CT and PET, not the temporal resolution. We therefore proposed the use of respiration-averaged CT (ACT) to match the temporal resolution of CT and PET and evaluated the improvement of tumor quantification in PET images of the thorax with ACT. METHODS: First, we examined 100 consecutive clinical PET/CT studies for the frequency and magnitude of misalignment at the diaphragm position between the HCT and the PET data. Patients were injected with 555-740 MBq of (18)F-FDG and scanned 1 h after injection. The HCT data were acquired at the following settings: 120 kV, 300 mA, pitch of 1.35:1, collimation of 8 x 1.25 mm, and rotation cycle of 0.5 s. Patients were instructed to hold their breath at midexpiration during HCT of the thorax. The PET acquisition was 3 min per bed. Second, we retrospectively analyzed studies of 8 patients (1 with esophageal cancer and 7 with lung cancer). Each study included regular PET/CT followed by 4-dimensional (4D) CT for radiation treatment planning. We compared the results of AC of the PET data with HCT and ACT. There were 13 tumors in these 8 patients. The 4D CT data were acquired at the following settings: 120 kV, 50-150 mA, cine duration of 1 breathing cycle plus 1 s, collimation of 8 x 1.25 mm, and rotation cycle of 0.5 s. The acquisition was taken when the patient was in the free-breathing state. We averaged the 10 phases of the 4D CT data to obtain ACT for AC of the PET data. Both the ACT and the HCT data were used for AC of the same PET data. RESULTS: There was a misalignment between the HCT and the PET data in 50 of 100 patient studies. In 34 studies, the misalignment was greater than 2 cm. In a comparison of HCT and ACT, 5 tumors had differences in standardized uptake values (SUV) between HCT-and ACT-attenuation-corrected PET of less than 20%, and 4 tumors had differences in SUV of more than 50%. The latter 4 tumors were found in the patient with esophageal cancer and in 2 of the patients with lung cancer. The PET data from these 3 patients had a misalignment of 2-4.5 cm relative to the HCT data. Breathing artifacts were significantly reduced by ACT. Seven of the 8 patients had a lower diaphragm position on HCT than on ACT, suggesting that the patients tended to hold a deeper breath during HCT than during ACT. CONCLUSION: The high rate of misalignment suggested a potential mismatch between the HCT and the PET data with the limited-breath-hold CT protocol. In the comparison of HCT and ACT, significant differences (>50%) in SUV were attributable to different breathing states between HCT and PET. The PET data corrected by ACT did not show breathing artifacts, suggesting that ACT may be more accurate than HCT for AC of the PET data.

Aged↗

Qualitative and quantitative comparison between images obtained with filtered back projection and iterative reconstruction in prostate cancer lesions of (18)F-FDG PET.

BACKGROUND: Recently, iterative reconstruction with segmented attenuation corrections (IRSAC) has been introduced for reconstruction of (18)F-FDG PET images. IRSAC produces images that are more pleasing to the eye, but qualitative and quantitative comparisons between IRSAC and filtered back projection (FBP) have not been reported for metastatic cancer. Since quantitative data has been widely used as an adjunct to interpretation of PET scans, comparison between IRSAC and FBP is needed. The purpose of this study was to compare image quality and the maximum standardized uptake value (SUVmax) obtained with FBP and with IRSAC in metastatic lesions from prostate cancer. METHODS: Twenty (18)F-FDG PET scans (10 baseline and 10 follow-up) were performed in 10 patients with prostate cancer (ages 66-85 yrs, mean 73.6 yrs). Acquisition began 45 min after injection of 370 MBq of (18)F-FDG. Images were reconstructed using FBP and IRSAC, and submitted to visual and quantitative analysis. SUVmax was obtained for all metastases, on FBP and IRSAC. A Jaszczak phantom study was also performed. RESULTS: IRSAC images showed better image quality than FBP especially in regions of high activity concentrations. IRSAC detected 106 lesions on both baseline and follow-up scans, while FBP detected 100 and 95 lesions on baseline and follow-up scans, respectively. Therefore, 17 more lesions were seen on IRSAC. The mean SUVmax values on baseline scans for FBP and IRSAC were systematically different, at 4.46+/-1.99 and 5.13+/-2.67, respectively. On follow-up scans values were 3.89+/-1.72 for FBP and 4.29+/-1.93 for IRSAC. Comparison of FBP with IRSAC on baseline and follow-up scans were statistically significant (baseline: paired "t"-test p=0.0017; follow-up: paired "t"-test p=0.0008). Phantom studies reveal that these differences can be explained by the type of reconstruction filters used, and IRSAC was more accurate than FBP. CONCLUSIONS: IRSAC detects smaller volumes in phantoms, patient images are easier to interpret and more metastatic lesions were detected. In addition, IRSAC provides reproducible quantitative data, comparable to data provided by FBP. IRSAC SUV and FBP SUV are in close agreement but there was a statistically significant difference between the two, and therefore threshold values of SUV will probably need to be re-determined with IRSAC, and are likely to be 10 to 19% higher than currently reported.

Adenocarcinoma↗

Standardized uptake value in pediatric patients: an investigation to determine the optimum measurement parameter.

Although the standardized uptake value (SUV) is currently used in fluorine-18 fluorodeoxyglucose positron emission tomography (FDG-PET) imaging, concerns have been raised over its accuracy and clinical relevance. Dependence of the SUV on body weight has been observed in adults and this should be of concern in the pediatric population, since there are significant body changes during childhood. The aim of the present study was to compare SUV measurements based on body weight, body surface area and lean body mass in the pediatric population and to determine a more reliable parameter across all ages. Sixty-eight pediatric FDG-PET studies were evaluated. Age ranged from 2 to 17 years and weight from 11 to 77 kg. Regions of interest were drawn at the liver for physiologic comparison and at FDG-avid malignant lesions. SUV based on body weight (SUV(bw)) varied across different weights, a phenomenon less evident when body surface area (SUV(bsa)) normalization is applied. Lean body mass-based SUV (SUV(lbm)) also showed a positive correlation with weight, which again was less evident when normalized to bsa (SUV(bsa-lbm)). The measured liver SUV(bw) was 1.1+/-0.3, a much lower value than in our adult population (1.9+/-0.3). The liver SUV(bsa) was 7.3+/-1.3. The tumor sites had an SUV(bw) of 4.0+/-2.7 and an SUV(bsa) of 25.9+/-15.4 (65% of the patients had neuroblastoma). The bsa-based SUVs were more constant across the pediatric ages and were less dependent on body weight than the SUV(bw). These results indicate that SUV calculated on the basis of body surface area is a more uniform parameter than SUV based on body weight in pediatric patients and is probably the most appropriate approach for the follow-up of these patients.

Adolescent↗

FDG-PET standardized uptake values in normal anatomical structures using iterative reconstruction segmented attenuation correction and filtered back-projection.

Filtered back-projection (FBP) is the most commonly used reconstruction method for PET images, which are usually noisy. The iterative reconstruction segmented attenuation correction (IRSAC) algorithm improves image quality without reducing image resolution. The standardized uptake value (SUV) is the most clinically utilized quantitative parameter of [fluorine-18]fluoro-2-deoxy-D-glucose (FDG) accumulation. The objective of this study was to obtain a table of SUVs for several normal anatomical structures from both routinely used FBP and IRSAC reconstructed images and to compare the data obtained with both methods. Twenty whole-body PET scans performed in consecutive patients with proven or suspected non-small cell lung cancer were retrospectively analyzed. Images were processed using both IRSAC and FBP algorithms. Nonquantitative or gaussian filters were used to smooth the transmission scan when using FBP or IRSAC algorithms, respectively. A phantom study was performed to evaluate the effect of different filters on SUV. Maximum and average SUVs (SUVmax and SUVavg) were calculated in 28 normal anatomical structures and in one pathological site. The phantom study showed that the use of a nonquantitative smoothing filter in the transmission scan results in a less accurate quantification and in a 20% underestimation of the actual measurement. Most anatomical structures were identified in all patients using the IRSAC images. On average, SUVavg and SUVmax measured on IRSAC images using a gaussian filter in the transmission scan were respectively 20% and 8% higher than the SUVs calculated from conventional FBP images. Scatterplots of the data values showed an overall strong relationship between IRSAC and FBP SUVs. Individual scatterplots of each site demonstrated a weaker relationship for lower SUVs and for SUVmax than for higher SUVs and SUVavg. A set of reference values was obtained for SUVmax and SUVavg of normal anatomical structures, calculated with both IRSAC and FBP image reconstruction algorithms. The use of IRSAC and a gaussian filter for the transmission scan seems to give more accurate SUVs than are obtained from conventional FBP images using a nonquantitative filter for the transmission scan.

Aged↗

Incidental focal thyroid uptake on FDG positron emission tomographic scans may represent a second primary tumor.

PURPOSE: This article discusses the value of incidental thyroid uptake of fluorodeoxyglucose (FDG) on whole-body positron emission tomography (PET) scans performed in patients with cancer. This issue has been reported diversely in the literature. MATERIALS AND METHODS: Whole-body PET scans of four patients with cancer (two of them women; age, 49 to 78 years) in whom focal thyroid uptake was visualized and subsequently correlated with thyroid carcinoma based on cytologic or histopathologic data were reviewed. The clinical outcomes of these patients were analyzed retrospectively. Maximum and average standardized uptake values (SUVs) of thyroid accumulation were recalculated in all patients. RESULTS: Two of the four patients referred for FDG PET scans had lung adenocarcinomas, one had prostate carcinoma, and one had an unknown primary tumor. Focal thyroid uptake was visualized, with maximum and average SUVs ranging from 3.7 and 2.3 to 53 and 34, respectively. These findings were correlated with cytologic (two patients) or histopathologic data (two patients) that indicated thyroid carcinoma. In two patients, their treatment was changed and total thyroidectomy was performed; in one of them the SUVs of the focal thyroid accumulation (maximum and average values of 7.9 and 4.8, respectively) were less than the cutoff values for thyroid cancer noted in the literature. The clinical condition of the other two patients did not permit additional investigation or treatment for thyroid carcinoma. CONCLUSION: Increased focal thyroid uptake on whole-body FDG PET scans should not be overlooked, even when it is not marked, and should prompt further investigation to rule out cancer.

Adenocarcinoma↗

Local detection of prostate cancer by positron emission tomography with 2-fluorodeoxyglucose: comparison of filtered back projection and iterative reconstruction with segmented attenuation correction.

BACKGROUND: To compare filtered back projection (FBP) and iterative reconstruction with segmented attenuation correction (IRSAC) in the local imaging of prostate cancer by positron emission tomography with 2-fluorodeoxyglucose (FDG-PET). METHODS: We retrospectively identified 13 patients with primary (n=7) or recurrent (n=6) prostate cancer who had increased uptake in the prostate on FDG-PET performed without urinary catheterization, contemporaneous biopsy confirming the presence of active tumor in the prostate, and correlative cross-sectional imaging by MRI (n=8) or CT (n=5). FDG-PET images were reconstructed by FBP and IRSAC. Two independent nuclear medicine physicians separately rated FBP and IRSAC images for visualization of prostatic activity on a 4-point scale. Results were compared using biopsy and cross-sectional imaging findings as the standard of reference. RESULTS: IRSAC images were significantly better that FBP in terms of visualization of prostatic activity in 12 of 13 patients, and were equivalent in 1 patient (p<0.001, Wilcoxon signed ranks test). In particular, 2 foci of tumor activity in 2 different patients seen on IRSAC images were not visible on FBP images. In 11 patients who had a gross tumor mass evident on cross-sectional imaging, there was good agreement between PET and cross-sectional anatomic imaging with respect to tumor localization. CONCLUSIONS: In selected patients, cancer can be imaged within the prostate using FDG-PET, and IRSAC is superior to FBP in image reconstruction for local tumor visualization.

Aged↗

The indications of FDG-PET in neck oncology.

FDG-PET imaging in neck oncology has a definite clinical impact in the post-therapy setting, assisting in the management of thyroid cancers and SCC of the neck. Quantitation of FDG uptake in suspicious areas may be helpful but should be regarded cautiously. Overall, wider incorporation of FDG imaging in clinical routine depends also on cost availability issues of FDG and of imaging devices. Dual-coincidence scanners for FDG imaging are much cheaper than dedicated PET scanners and are installed in growing numbers in many centers. These devices have inferior sensitivity; however, series published with these scanners produce encouraging results. Easier and more acceptable clinical application will also be facilitated by the systematic use of coregistration with anatomic images. Both prerequisites might be fulfilled by the emergence on the market of a gamma camera-mounted anatomic X-ray tomograph, which in addition to dual-coincidence scintigraphic imaging provides radiographic images of comparable quality to third-generation CT systems. This type of hybrid gamma camera-CT scanner has great potential in a region of complex anatomy, such as the head and neck.

Carcinoma, Squamous Cell↗

Ga-67 uptake in cutaneous lesions of graft-versus-host disease.

Acute graft-versus-host disease (GVHD) usually involves the skin, gastrointestinal tract, and liver. A 47-year-old woman with fever of unknown origin was referred for a Ga-67 scan. The study showed diffuse uptake of Ga-67 throughout the skin. Subsequently, a skin biopsy confirmed the diagnosis of acute GVHD. The incidence, diagnosis, and pathophysiology of the dermatitis in acute GVHD are discussed.

Female↗

Sequential dose-intensive paclitaxel, ifosfamide, carboplatin, and etoposide salvage therapy for germ cell tumor patients.

PURPOSE: To evaluate the efficacy and toxicity of sequential, dose-intensified chemotherapy with paclitaxel/ifosfamide and carboplatin/etoposide administered plus peripheral blood-derived stem-cell (PBSC) support for patients with germ cell tumors (GCT) who have unfavorable prognostic features in response to conventional-dose salvage programs. Carboplatin was dose escalated by target area under the curve (AUC; in [milligrams per milliliter] x minutes) among patient cohorts, and pharmacokinetic studies were performed for comparison. PATIENTS AND METHODS: Thirty-seven previously treated patients who had cisplatin-resistant GCT and unfavorable prognostic features for response to conventional-dose salvage therapy were treated. Two cycles of paclitaxel 200 mg/m(2) plus ifosfamide 6 g/m(2) were given 2 weeks apart with leukapheresis, followed by three cycles of carboplatin plus etoposide given 14 to 21 days apart with reinfusion of PBSCs. The dose of etoposide was 1, 200 mg/m(2), and the carboplatin target AUC ranged among cohorts from 12 to 32 (mg/mL) x min. Pharmacokinetic studies of carboplatin were performed for comparison of target to measured AUC. RESULTS: Twenty-one patients (57%) achieved a complete response and an additional two patients (5%) achieved a partial response with normal tumor markers; therefore, 23 (62%) achieved a favorable response. Eight patients relapsed, and 15 (41%) of the favorable responses remained durable at a median follow-up of 30 months. Myelosuppression was the major toxicity; 58% of carboplatin/etoposide cycles were associated with hospitalization for nadir fever. The AUC of carboplatin measured in serum was lower than the target AUC; this may be related to underestimation of the glomerular filtration rate used in the dosing formula. CONCLUSION: Dose-intense therapy with sequential, accelerated chemotherapy of paclitaxel/ifosfamide and carboplatin/etoposide administered with PBSC support was relatively well tolerated. The durable complete response proportion was substantial in patients with unfavorable prognostic features for achieving durable complete response to conventional-dose salvage programs. Optimal dosing of carboplatin in the high-dose setting warrants further investigation.

Adolescent↗

Pilot clinical trial of 5-[125I]iodo-2'-deoxyuridine in the treatment of colorectal cancer metastatic to the liver.

UNLABELLED: The thymidine analog, 5-iodo-2'-deoxyuridine (IUdR), is incorporated in the DNA of cells in the S phase. When incorporated into DNA, short-range Auger electrons emitted by 125I-labeled IUdR can cause double-strand breaks, delivering a lethal radiation dose to the cell. We conducted therapeutic trial to evaluate[125I/131I]IUdR pharmacokinetics in liver metastases from colorectal cancer. Dosimetry, safety, and therapeutic potential were assessed. METHODS: Four patients were each infused with 5 mCi [125I]IUdR and 10 mCi [131I]IUdR through the sideport of a hepatic artery pump. Iodine-131 images were quantitated and used for pharmacokinetic studies. The radioactivity in the DNA of biopsy samples of tumor, normal liver and bone marrow, obtained 24 or 48 hr after injection, was counted. RESULTS: All patients had [125I]IUdR and [131I]IUdR uptake in tumor, with a biexponential clearance. Repeat injections in individual patients showed little variation in tumor uptake, especially in the slow clearance component. On planar images, no long-term retention was seen in bone marrow or other actively dividing normal tissues. Radioactivity in all tumor DNA samples was greater than background, while that in normal liver cell DNA was at background levels. Radioactivity in the DNA of one marrow sample taken at 24 hr was above background, but in another taken at 48 hr it was equal to background levels. No side effects were noted, no hematologic toxicity was observed in any patients and no tumor responses were seen. CONCLUSION: There is persistent uptake of [125I]IUdR in hepatic tumors, thereby making hepatic artery infusion a suitable mode of delivery for therapy. Repeat injections will be needed because only 15%-50% of tumor cells are in the S phase. Based on results from this pilot study, a therapeutic regimen is being planned.

Adult↗

Pharmacokinetics and dosimetry of iodine-125-IUdR in the treatment of colorectal cancer metastatic to liver.

UNLABELLED: The radiotoxicity of 125I is highly sensitive to the site of decay relative to nuclear DNA. This paper describes a new approach, based upon pharmacokinetic clearance of radioactivity from the tumor, with which to quantify the fraction of [125I]IUdR incorporated within the DNA of tumor cells. METHODS: Patients were injected with [125I]IUdR through the hepatic artery. Iodine-131-IUdR was used as a tracer for imaging and quantitation. Both conventional and DNA-level dosimetry were performed. RESULTS: We calculated that if 15% of the tumor cells were in S phase at the time of injection, there would be 250 decays of 125I in the DNA per tumor cell after an infusion of 5 mCi [125I]IUdR. According to in vitro data based on 5 x 10(8) cells per g tumor, 99% of these cells in S phase would be killed. CONCLUSION: The estimate of cell inactivation is strongly dependent on the number of cells per gram and the fraction of cells in S phase at the time of injection, which indicates that repeat injections would be necessary to achieve a therapeutic effect.

Bone Marrow↗

Somatostatin-receptor imaging in lymphoma.

Patients with Hodgkin's or non-Hodgkin's lymphoma are staged for treatment based on the extent of known disease involvement and the histopathologic grading of the disease. Radiological techniques, including computed tomography, usually depend on estimates of lymph node enlargement and mass effects as the criterion for disease involvement. Lymphomatous tissue obtained at surgery has shown high-density somatostatin receptors. Several groups have evaluated the utility of 111In-DTPA-pentetreotide (Octreoscan, Mallinckrodt, St. Louis, MO) to detect lymphomatous tissue for more accurate staging of patients with lymphoma. The procedure is safe; both Hodgkin's and non-Hodgkins disease involvement is identified. The results, however, have not been uniformly predictive of disease involvement. Consequently, the routine use of this technique in place of currently used anatomic imaging methods is not recommended at this time. The significance of detecting somatostatin receptors in vivo in patients with malignant lymphoma requires further study.

Adult↗

The value of thallium and three-phase bone scans in the evaluation of bone and soft tissue sarcomas.

Thirty-seven patients with newly diagnosed or treated sarcomas had 47 sets of sequential thallium scans (TS) followed by three-phase bone scan (TPBS) on the same day. The diagnosis in all patients was verified by biopsy (n = 40) or long-term follow-up studies (n = 7). The sensitivity, specificity, and accuracy of TS and TPBS in detecting sarcomatous lesions was calculated: TS sensitivity was 88%, specificity 69%, and accuracy 83%; blood flow (BF) and blood pool (BP) sensitivity was 91%, specificity 54%, and accuracy 81%; delayed bone scan (DB) sensitivity was 88%, specificity 38%, and accuracy 74%. In 17 studies the flow and blood pool parts of the TPBS and TS demonstrated the soft tissue component of sarcomas, which would have been missed if only the delayed bone scan had been performed. The TS lesion to normal tissue ratio alone was not very helpful in differentiating sarcomas from benign conditions because some benign lesions are highly cellular and vascular while some malignant lesions, such as chondrosarcoma, have poor vascularity and a less cellular chondroid matrix. However, when the thallium ratio was correlated with similar ratios calculated from the BP image, it was found that if the TS lesion to normal tissue ratio exceeded the BP lesion to normal tissue ratio (12 patients), the specificity for detecting sarcomatous lesions was 100%. Nevertheless, the reverse was not true. The positive predictive value of this observation was 100% and the negative predictive value was 37%.

Adolescent↗

Gallium-67-citrate imaging in nuclear oncology.

Gallium-67-citrate is one of the most useful radiopharmaceuticals to detect tumors, stage extent of the disease, monitor response to treatment and distinguish recurrent disease from post-treatment changes. Gallium is likewise very sensitive to detect and locate infections and inflammatory foci. This application is extremely important in the management of immunocompromised cancer patients. Image interpretation should be tempered with full knowledge of the patients clinical condition, anatomic alterations due to prior surgery and correct timing of image acquisition. Early imaging at 4-6 h is useful to detect gastrointestinal infections, whereas 24 h imaging is used to evaluate chest infections. Although gallium-67 is a non-specific agent, the identification of the etiology of the inflammation may be improved by adequate clinical and laboratory information as well as correlation with other imaging modalities such as sonography and computerized x-ray tomography (CT). High dose (10 mCi) gallium-67 single photon emission computed tomography (SPECT) imaging with image co-registration is important for accurate uptake localization.

Citrates↗

Flare on bone scintigraphy following Taxol chemotherapy for metastatic breast cancer.

UNLABELLED: Our goal was to determine if a healing flare response seen on bone scintigraphy occurs following chemotherapy with Taxol (paclitaxel; Bristol-Myers Squibb Co., Princeton, NJ), a novel antimicrotubule agent for metastatic breast cancer. METHODS: We performed 74 bone scans on 21 females with breast cancer and bone metastases entering a Phase II trial of Taxol chemotherapy with granulocyte colony stimulating factor (G-CSF). All patients had baseline scans within 6 wk prior to therapy, after the second cycle (4-6 wk) of Taxol, and then after 6-12 mo. All bone scans were reviewed by two nuclear medicine physicians, without knowledge of the patients' clinical history. Skeletal radiographs, CT and MRI scans, as well as clinical history were compared with scan findings. RESULTS: Seven of the 21 patients showed improvement in bone scan findings. Of these seven, three had a flare response following two cycles (4-6 wk) of Taxol, characterized by increased activity in baseline lesions and the appearance of new lesions, followed by improvement on follow-up scans. Evidence of clinical response (> or = 50% reduction in tumor mass) was seen in all of these patients. Seven patients showed no change in baseline findings on follow-up bone scans. Seven patients had post-Taxol scans showing new lesions, with no overall improvement on later follow-up. CONCLUSION: Flare on bone scintigraphy may be seen shortly after commencing Taxol chemotherapy. Bone scans done within the first 3 mo must be interpreted with caution and should be correlated with clinical and radiological findings to avoid inappropriate discontinuation of Taxol chemotherapy.

Adenocarcinoma↗

Clinical validation of SPECT and CT/MRI image registration in radiolabeled monoclonal antibody studies of colorectal carcinoma.

UNLABELLED: Registration methods combine the anatomic localizing ability of CT or MRI with SPECT images of radiolabeled monoclonal antibodies (Mabs), allowing the accurate staging of patients prior to surgery or following treatment. METHODS: Twenty-four patients (15 males and 9 females, mean age 55 yr, range 29-70 yr) were studied with this technique. Ten patients had suspected colorectal cancer recurrence and were infused with 10 mCi of 131I-CC49 prior to staging laparotomy. Fourteen patients treated in a Phase I radioimmunotherapy study with 131I-CC49 were also studied. All patients underwent SPECT imaging of the abdomen and pelvis 5-7 days following infusion of Mab. RESULTS: Phantom studies demonstrated a 3.6-mm surface fitting mean accuracy of datasets for the liver and 1.8 mm for an intrahepatic tumor. In the presurgical group, SPECT and CT/MRI registration allowed more accurate identification of uptake abnormal sites. Areas of metastatic disease > 1 cm confirmed at surgery were found in six of nine patients with liver lesions and in two patients with extrahepatic (including one patient with pelvic) disease. In patients imaged following radioimmunotherapy, all lesions > 1.5 cm seen on CT/MRI were identified, and activity distribution in tumor and normal tissue could be more accurately assessed. CONCLUSIONS: Routine registration of SPECT and CT/MRI images is feasible and allows more accurate anatomic assessment of sites of abnormal uptake in radiolabeled Mab studies.

Adrenal Gland Neoplasms↗