PubMed Health⌕ Search

Biomedical subjects

H A Woutman

Publications and source records attributed to H A Woutman.

2 recordsLinked to original sources

Characterization of plaque components with intravascular ultrasound elastography in human femoral and coronary arteries in vitro.

BACKGROUND: The composition of plaque is a major determinant of coronary-related clinical syndromes. Intravascular ultrasound (IVUS) elastography has proven to be a technique capable of reflecting the mechanical properties of phantom material and the femoral arterial wall. The aim of this study was to investigate the capability of intravascular elastography to characterize different plaque components. METHODS AND RESULTS: Diseased human femoral (n=9) and coronary (n=4) arteries were studied in vitro. At each location (n=45), 2 IVUS images were acquired at different intraluminal pressures (80 and 100 mm Hg). With the use of cross-correlation analysis on the high-frequency (radiofrequency) ultrasound signal, the local strain in the tissue was determined. The strain was color-coded and plotted as an additional image to the IVUS echogram. The visualized segments were stained on the presence of collagen, smooth muscle cells, and macrophages. Matching of elastographic data and histology were performed with the use of the IVUS echogram. The cross sections were segmented in regions (n=125) that were based on the strain value on the elastogram. The dominant plaque types in these regions (fibrous, fibro-fatty, or fatty) were obtained from histology and correlated with the average strain and echo intensity. The strain for the 3 plaque types as determined by histology differed significantly (P=0.0002). This difference was mainly evident between fibrous and fatty tissue (P=0.0004). The plaque types did not reveal echo-intensity differences in the IVUS echogram (P=0.882). CONCLUSIONS: Different strain values are found between fibrous, fibro-fatty, and fatty plaque components, indicating the potential of intravascular elastography to distinguish different plaque morphologies.

Arteries↗

Vascular tissue characterisation with IVUS elastography.

Knowledge about the mechanical properties of the vessel wall and plaque is important for guiding intravascular interventional procedures and detection of plaque vulnerability. Rupture of atherosclerotic plaques is associated with acute myocardial infarction and unstable angina pectoris. In a plaque with a lipid core, the stress due to the arterial pulsation will be concentrated in the cap and a thin cap may be unable to bear this stress. In this study, the potential of intravascular elastography to characterise fibrous, fibro-fatty and fatty tissue based on their mechanical properties was investigated. Using a custom-made set-up, intravascular echograms and elastograms of excised human femoral arteries were determined. High frequency r.f. data (30 MHz) were acquired using an intravascular catheter. The tissue was compressed using intravascular pressures of 80 and 100 mmHg. The cross-sections of interest were marked with a needle for matching with histology. Using cross-correlation estimation of gated echosignals, elastograms (images of the local strain) were determined. After the intravascular experiments, the specimens were fixed in formaldehyde and processed for paraffin embedding. Sections were stained with picrosirius red and alpha-actin to counterstain collagen and smooth muscle cells (SMC), respectively. Results of vessel cross-sections with fibrous and fatty plaque regions will be presented. The elastograms of these specimens show that the strain in fatty tissue is higher than the strain in fibrous material. In conclusion, these in vitro experiments on human femoral arteries indicate the potential of intravascular elastography to characterise different plaque components.

Arteriosclerosis↗