PubMed Health⌕ Search

Biomedical subjects

H Ade

Publications and source records attributed to H Ade.

11 recordsLinked to original sources

Carbon-13 labeling for improved tracer depth profiling of organic materials using secondary ion mass spectrometry.

13C labeling is introduced as an alternative to deuterium labeling for analysis of organic materials using secondary ion mass spectrometry (SIMS). A model macromolecular system composed of polystyrene (PS) and poly(methyl methacrylate) (PMMA) was used to compare the effects of isotopic labeling using both deuterium substitution (dPS) and 13C labeling (13C-PS). Clear evidence is shown that deuterium labeling does introduce changes in the thermodynamic properties of the system, with the observation of segregation of dPS to an hPS:dPS/hPMMA interface. This type of behavior could significantly impact many types of investigations due to the potential for improper interpretation of experimental results as a consequence of labeling-induced artifacts. 13C labeling is shown to provide a true tracer for analysis using SIMS.

Carbon Isotopes↗

Carbon-13 labeled polymers: an alternative tracer for depth profiling of polymer films and multilayers using secondary ion mass spectrometry.

13C labeling is introduced as a tracer for depth profiling of polymer films and multilayers using secondary ion mass spectrometry (SIMS). Deuterium substitution has traditionally been used in depth profiling of polymers but can affect the phase behavior of the polymer constituents with reported changes in both bulk-phase behavior and surface and interfacial interactions. SIMS can provide contrast by examining various functional groups, chemical moieties, or isotopic labels. 13C-Labeled PS (13C-PS) and unlabeled PS (12C-PS) and PMMA were synthesized using atom-transfer radical polymerization and assembled in several model thin-film systems. Depth profiles were recorded using a Cameca IMS-6f magnetic sector mass spectrometer using both 6.0-keV impact energy Cs+ and 5.5-keV impact energy O2+ primary ion bombardment with detection of negative and positive secondary ions, respectively. Although complete separation of 12C1H from 13C is achieved using both primary ion species, 6.0-keV Cs+ clearly shows improved detection sensitivity and signal-to-noise ratio for detection of 12C, 12C1H, and 13C secondary ions. The use of Cs+ primary ion bombardment results in somewhat anomalous, nonmonotonic changes in the 12C, 12C1H, and 13C secondary ion yields through the PS/PMMA interface; however, it is shown that this behavior is not due to sample charging. Through normalization of the 13C secondary ion yield to the total C (12C + 13C) ion yield, the observed effects through the PS/PMMA interface can be greatly minimized, thereby significantly improving analysis of polymer films and multilayers using SIMS. Mass spectra of 13C-PS and 12C-PS were also analyzed using a PHI TRIFT I time-of-flight mass spectrometer, with 15-keV Ga+ primary ion bombardment and detection of positive secondary ions. The (12)C7(1)H7 ion fragment and its 13C-enriched analogues have significant secondary ion yields with negligible mass interferences, providing an early indication of the potential for future use of this technique for cluster probe depth profiling of high molecular weight 13C-labeled fragments.

Journal Article↗

Substrate effect on the melting temperature of thin polyethylene films.

Strong dependence of the crystal orientation, morphology, and melting temperature (Tm) on the substrate is observed in the semicrystalline polyethylene thin films. The Tm decreases with the film thickness decrease when the film is thinner than a certain critical thickness, and the magnitude of the depression increases with increasing surface interaction. We attribute the large Tm depression to the decrease in the overall free energy on melting, which is caused by the substrate attraction force to the chains that competes against the interchain force which drives the chains to crystallization.

Crystallization↗

Attractive migration and coalescence: a significant process in the coarsening of TiSi2 islands on the Si(111) surface.

The dynamics and coarsening of TiSi2 islands on Si(111) surfaces are studied in real time with photoelectron emission microscopy. A significant fraction of events are observed in which nearby islands move attractively toward each other and subsequently coalesce. It is proposed that attractive island migration is due to the growth-decay flow of the island edges driven by a nonuniform surface concentration around the islands. The local surface concentration is induced by the neighboring islands. This coarsening mechanism should significantly affect the evolution of the island distribution.

Journal Article↗

Interferometer-controlled scanning transmission X-ray microscopes at the Advanced Light Source.

Two new soft X-ray scanning transmission microscopes located at the Advanced Light Source (ALS) have been designed, built and commissioned. Interferometer control implemented in both microscopes allows the precise measurement of the transverse position of the zone plate relative to the sample. Long-term positional stability and compensation for transverse displacement during translations of the zone plate have been achieved. The interferometer also provides low-distortion orthogonal x, y imaging. Two different control systems have been developed: a digital control system using standard VXI components at beamline 7.0, and a custom feedback system based on PC AT boards at beamline 5.3.2. Both microscopes are diffraction limited with the resolution set by the quality of the zone plates. Periodic features with 30 nm half period can be resolved with a zone plate that has a 40 nm outermost zone width. One microscope is operating at an undulator beamline (7.0), while the other is operating at a novel dedicated bending-magnet beamline (5.3.2), which is designed specifically to illuminate the microscope. The undulator beamline provides count rates of the order of tens of MHz at high-energy resolution with photon energies of up to about 1000 eV. Although the brightness of a bending-magnet source is about four orders of magnitude smaller than that of an undulator source, photon statistics limited operation with intensities in excess of 3 MHz has been achieved at high energy resolution and high spatial resolution. The design and performance of these microscopes are described.

Journal Article↗

Optimization of scanning transmission X-ray microscopy for the identification and quantitation of reinforcing particles in polyurethanes.

The morphology, size distributions, spatial distributions, and quantitative chemical compositions of co-polymer polyol-reinforcing particles in a polyurethane have been investigated with scanning transmission X-ray microscopy (STXM). A detailed discussion of microscope operating procedures is presented and ways to avoid potential artifacts are discussed. Images at selected photon energies in the C 1s, N 1s and O 1s regions allow unambiguous identification of styrene-acrylonitrile-based (SAN) copolymer and polyisocyanate polyaddition product-based (PIPA) reinforcing particles down to particle sizes at the limit of the spatial resolution (50 nm). Quantitative analysis of the chemical composition of individual reinforcing particles is achieved by fitting C 1s spectra to linear combinations of reference spectra. Regression analyses of sequences of images recorded through the chemically sensitive ranges of the C 1s, N 1s and O 1s spectra are used to generate quantitative compositional maps, which provide a fast and effective means of investigating compositional distributions over a large number of reinforcing particles. The size distribution of all particles determined by STXM is shown to be similar to that determined by TEM. The size distributions of each type of reinforcing particle, which differ considerably, were obtained by analysis of STXM images at chemically selective energies.

Microscopy, Electron, Scanning↗

Illumination for coherent soft X-ray applications: the new X1A beamline at the NSLS.

The X1A soft X-ray undulator beamline at the NSLS has been rebuilt to serve two microscopy stations operating simultaneously. Separate spherical-grating monochromators provide the resolving power required for XANES spectroscopy at the C, N and O absorption edges. The exit slits are fixed and define the coherent source for the experiments. The optical design and the operational performance are described.

Journal Article↗

Chemical contrast in X-ray microscopy and spatially resolved XANES spectroscopy of organic specimens.

The scanning transmission x-ray microscope at the National Synchrotron Light Source has been used to record x-ray absorption near-edge structure (XANES) spectra from 0.01-square-micrometer regions of organic specimens. The spectral features observed reflect the molecular structure of the dominant absorbing atoms and provide the contrast mechanism for high-resolution imaging with chemical sensitivity. This technique was used with x-ray energies near the carbon K absorption edge to identify and map separate phases in various polymer blends and to map the DNA distribution in chromosomes with a spatial resolution of 55 nanometers.

Acrylic Resins↗

The interior of a whole and unmodified biological object--the zymogen granule--viewed with a high-resolution X-ray microscope.

We report the ability of focused soft X-rays to visualize at spatial resolution well beyond that of the optical microscope (less than 100 nm) the interior of a small, whole biological object without fixation, staining, dehydration or sectioning. Quantitative estimation of its protein content with unique femtogram sensitivity is also reported. The present results represent a significant step towards the goals of natural imaging and chemical mapping of biological structures with soft X-rays.

Animals↗