PubMed Health⌕ Search

Biomedical subjects

H Ahlström

Publications and source records attributed to H Ahlström.

At least 19 recordsLinked to original sources

Quantification of intramyocellular lipids in obese subjects using spectroscopic imaging with high spatial resolution.

Quantification of intramyocellular lipids (IMCL) in obese subjects by single-voxel spectroscopy (SVS) or conventional spectroscopic imaging (SI) often fails due to overlap of IMCL spectral lines by extramyocellular lipids (EMCL), and signal contamination from subcutaneous fat and bone marrow. This study demonstrates that these problems can be solved by high-resolution SI with 128 phase-encoding steps and a read gradient during acquisition. The small voxels obtained in this way facilitated differentiation between EMCL and IMCL. This method offers the possibility of studying different muscle groups and the variation of lipids within one muscle.

Adult↗

The prevalence and quantification of atherosclerosis in an elderly population assessed by whole-body magnetic resonance angiography.

OBJECTIVE: The principal aim of the present study was to explore the feasibility of using whole-body magnetic resonance angiography to assess atherosclerosis in different vascular territories in a cohort of elderly. METHODS AND RESULTS: Three hundred six 70-year-old subjects (145 women, 161 men) recruited from a population-based cohort study (Prospective Investigation of the Vasculature in Uppsala Seniors, ie, the PIVUS study) underwent 1.5-T whole-body magnetic resonance angiography with gadodiamide. The arteries were divided into 26 segments. In total, 7956 vessel segments were evaluated with 7900 segments (99.3%) possible to evaluate. Of these, 7186 segments (91%) were normal. Luminal narrowing of > or = 50% was observed in 9 (1.5%) of the renal arteries, 12 (1.8%) of the carotid arteries, in 31 segments (1.1%) of the pelvic/upper leg territories, and in 136 segments (6.2%) of territories in the lower leg. Approximately one-third of the sample had no vascular abnormalities, one-third had stenoses of < 50%, and the remainder had stenoses > or = 50% or occlusions. Six subjects (2%) had aortic aneurysms. In subjects without evident vascular disease, 26% had significant vascular abnormalities. CONCLUSIONS: Whole-body magnetic resonance angiography performed with a clinical scanner can be used for quantifying atherosclerosis in different vascular territories in a single examination in an elderly population.

Age Distribution↗

Macrophage uptake of ultra-small iron oxide particles for magnetic resonance imaging in experimental acute cardiac transplant rejection.

PURPOSE: To discriminate between acutely rejecting and non-rejecting transplanted hearts using a blood pool contrast agent and T2* magnetic resonance imaging (MRI) in a clinical 1.5T scanner. MATERIAL AND METHODS: Allogeneic and syngeneic heterotopic heart transplantations were performed in rats. One allogeneic and one syngeneic group each received either the ultra-small iron oxide particle (USPIO), at two different doses, or no contrast agent at all. MRI was performed on postoperative day 6. Immediately after the MR scanning, contrast agent was injected and a further MRI was done 24 h later. Change in T2* was calculated. RESULTS: No significant difference in change in T2* could be seen between rejecting and non-rejecting grafts in either of the doses, or in the control groups. There was a difference between the allogeneic group that received the higher contrast agent dose and the allogeneic group that did not receive any contrast agent at all. CONCLUSION: In our rat model, measurements of T2* after myocardial macrophage uptake of AMI-227 in a clinical 1.5T scanner were not useful for the diagnosis of acute rejection.

Acute Disease↗

A prospective comparison of duplex ultrasonography, captopril renography, MRA, and CTA in assessing renal artery stenosis.

PURPOSE: To prospectively compare the diagnostic accuracy of duplex ultrasonography, captopril renography, computed tomography angiography (CTA), and 3D Gd magnetic resonance angiography (MRA) in diagnosing hemodynamically significant renal artery stenosis (RAS). MATERIAL AND METHODS: The standard of reference was measurement of transstenotic pressure gradient. Fifty-eight hypertensive patients with suspicion of RAS were evaluated, when possible, by all five techniques. Sensitivity and specificity to detect RAS were compared for each technique on both a patient and kidney basis. Discrepancies were evaluated separately and classified as borderline, method dependent, or operator dependent. RESULTS: The prevalence of RAS was 77%. The sensitivity/specificity of ultrasonography, captopril renography, CTA, and MRA in detecting kidneys with RAS was 73/71%, 52/63%, 94/62%, and 93/91%, respectively. Ultrasonography had a significantly lower sensitivity than CTA and MRA (P<0.001) but higher than captopril renography (P = 0.013). Borderline RAS was the main cause for discrepancies. CONCLUSION: MRA and CTA were significantly better than duplex ultrasonography and captopril renography in detecting hemodynamically significant RAS. The ultrasonography criteria for RAS based on the evaluation of renal peak systolic velocity and renal/aortic ratio are questionable. Captopril renography cannot be recommended for assessing RAS.

Adult↗

Chemical-shift micro-imaging of subcutaneous lesions.

A chemical-shift imaging technique was used for the study of small subcutaneous lesions. This study concerns micro-imaging of two females suffering from a tenosynovial giant cell tumor and an epidermal cyst. High-resolution water, fat and chemical-shift artifact-free images were obtained on a whole-body MR unit (1.5 T) equipped with a 23-mm microscopy surface coil and standard gradients (23 mT/m). A significant improvement in signal-to-noise ratio was achieved by reducing the receiver bandwidth to values below +/-10 kHz. The image data sets were acquired with resolution 0.1 x 0.13 mm in the plane, slice thickness 0.5 mm and with acquisition time less than 3 min. Spatial resolution, fat suppression, image texture and edge delineation were improved on spectroscopic images compared with those on conventional MR images.

Adult↗

Src family kinase-inhibitor PP2 reduces focal ischemic brain injury.

OBJECTIVES: To investigate the neuroprotective potential of the Src family kinase (SFK) inhibitor 4-amino-5-(4-chlorophenyl)-7-(t-butyl) pyrazolo(3,4-d)pyrimidine (PP2) in transient focal cerebral ischemia in the rat. MATERIAL AND METHODS: Sprague-Dawley rats were exposed to transient (90 min) middle cerebral artery occlusion (MCAO) and evaluated after 1 day of survival. PP2 (1.5 mg/kg i.p.) or vehicle was given 30 min after MCAO. The lesions were examined with magnetic resonance imaging (MRI), tri-phenyl tetrazolium chloride (TTC) staining and the functional outcome was determined using neurological scoring according to Bederson et al. RESULTS: PP2-treated rats showed approximately 50% reduction of infarct size on T2-weighted MRI and in TTC staining compared with controls (P < 0.05). Moreover, the neurological score was better in the PP2 group than controls (P < 0.05). CONCLUSION: PP2 is a potential neuroprotective agent in cerebral ischemia-reperfusion. The interference of PP2 with SFKs and/or other pathways remains to be elucidated.

Animals↗

Increased brain injury and vascular leakage after pretreatment with p38-inhibitor SB203580 in transient ischemia.

OBJECTIVES: Focal cerebral ischemia activates intracellular signaling pathways including the mitogen-activated protein kinase p38, which may be involved in the process of ischemic brain injury. In this study, the effect of pretreatment with the p38-inhibitor SB203580 on infarct size and blood-brain barrier (BBB) breakdown was investigated with magnetic resonance imaging (MRI). MATERIALS AND METHODS: Rats were given SB203580 (n = 6) or vehicle (n = 6) in the right lateral ventricle prior to transient (90 min) middle cerebral artery occlusion (MCAO) on the left side. The rats were examined with serial MRI during MCAO, at reperfusion and after 1 and 4 days. RESULTS: The mean infarct size on T2-weighted images after 1 day was significantly higher in the SB203580-treated group than in controls (300 +/- 95 mm3 vs 126 +/- 75 mm3; P < 0.01). Vascular gadolinium leakage, indicating BBB breakdown, was significantly larger in the SB203580-treated group than in controls after 1 day (median leakage score 18.5; range 15-21 vs 6.5; 4-17; P < 0.05) and 4 days (11; 6-15 vs 3.5; 1-9; P < 0.05), although no significant difference was seen initially. CONCLUSION: Pretreatment with SB203580 may aggravate ischemic brain injury and cerebral vascular leakage in the present model of transient ischemia.

Animals↗

Safety of nasal budesonide in the long-term treatment of children with perennial rhinitis.

BACKGROUND: Intranasal budesonide is an efficacious treatment for perennial allergic rhinitis. Long-term effects on safety, particularly in children, need further investigation. OBJECTIVE: To investigate the long-term safety of intranasal budesonide in children. METHODS: In an open trial, 78 children (5-15 years) with perennial rhinitis were treated with intranasal budesonide pressurized metered dose inhaler 200 microg twice daily (delivered daily dose 256 microg) for 12 months; 43 children stayed in the study for 12 additional months and were switched to aqueous suspension (400 microg delivered daily dose) for 6 months. Statural growth, bone age, ophthalmologic and rhinoscopic status, cortisol and biochemical analyses in blood and urine were monitored during the first and second years, and adverse events (AEs) were continuously recorded. RESULTS: No significant effects on statural growth and bone age, compared with reference values, were observed. Morning plasma cortisol and 24-h urinary cortisol were not changed during treatment. Patients reported 195 AEs, most commonly nasal dryness (30%), blood-tinged secretions (21%) and, among non-nasal AEs, headache (13%). Rhinoscopy revealed no signs of mucosal atrophy, ulceration, or candidiasis but some nasal dryness. No treatment-related ophthalmological or biochemical aberrations were found. Reduction of blood eosinophils and nasal symptom scores, compared with pre-treatment values, indicated the efficacy of budesonide treatment. CONCLUSION: Long-term treatment for 1-2 years with intranasal budesonide 256-400 microg daily in children with perennial rhinitis revealed no negative effects on growth or endogenous cortisol production. Local side-effects were mild and patient symptoms decreased.

Administration, Intranasal↗

The importance of adjusting for differences in proximal and distal contrast bolus arrival times in contrast-enhanced iliac artery magnetic resonance angiography.

We tested the hypothesis that differences in proximal and distal contrast bolus arrival times may result in insufficient vascular signal in the distal part of the aortoiliofemoral territory with routinely used timing techniques. The difference in arrival time of the contrast medium bolus between the aorta and the common femoral arteries was measured in 14 patients undergoing magnetic resonance angiography of the aortoiliac arteries. A dual-station test bolus technique adjusting for this difference was evaluated. The variation coefficient of the signal intensity in six defined locations and signal intensities (SI) normalised to fat were calculated. Comparisons were made with findings in 13 patients examined with a fluoroscopically triggered timing technique (BolusTrak, Philips Medical Systems, Best, The Netherlands). The difference in bolus arrival time between proximal and distal vessels was 0-7 s. In 3 of 14 patients it was 5.6-7 s. There was a tendency towards a lower mean variation coefficient in the dual-station group ( p=0.10). With both techniques, significantly lower SIs were measured in the femoral arteries compared with SIs in the superior part of the abdominal aorta. In two cases in the BolusTrak group, a distal vessel could not be delineated but was shown to be patent on a delayed scan. Differences in contrast medium arrival time along the vessel may be large enough to preclude visualisation of distal vessels unless there is compensation. A dual-station test bolus technique taking this into account was found to be feasible.

Adult↗

High-resolution carotid artery MRA. Comparison with fast dynamic acquistion and duplex ultrasound scanning.

PURPOSE: To determine whether the diagnostic accuracy of contrast-enhanced MR angiography (CE-MRA) of the carotid arteries is improved by using a slow-injection, high-resolution technique. MATERIAL AND METHODS: In 22 patients suspected to have internal carotid artery (ICA) stenosis at duplex ultrasound scanning (DUS), CE-MRA was performed both with a fast, dynamic (8 s/phase) and with a slower, high-resolution technique (scan time 2:20 min). RESULTS: There was conformity between the CE-MRA techniques regarding the degree of stenosis in 34/40 extracranial ICAs. In 3/6 discrepant cases, short occlusions were seen with the fast dynamic technique, whereas both the high-resolution CE-MRA technique and DUS showed patent vessels. There was an overall tendency toward higher stenosis grading with the dynamic technique. Overlying veins could be removed on a workstation in all high-resolution examinations. CONCLUSION: The high-resolution carotid CE-MRA technique proposed herein seems to improve the diagnostic accuracy, at least for differentiation between high-grade stenoses and occlusions.

Carotid Artery, Internal↗

Contrast agents in acute myocardial infarction.

The experimental design in examination of acute myocardial infarctions should be valid in terms of flow, perfusion and re-flow after intervention. The contrast agents concentration in experimental studies can be measured by microdialysis. We have assessed the usefulness of different extracellular and blood pool contrast agents for visualization of the area at risk in coronary artery occlusions. The double contrast technique, where Dy-DTPA-BMA was combined with Gd-DTPA-BMA yielded a superior infarct visualization. Blood pool agents for example NC100/150 injection is also promising in first path myocardial perfusion imaging.

Contrast Media↗

Spectroscopic imaging of bone marrow composition in vertebral bodies.

The proton spectroscopic imaging technique that uses read gradient during acquisition was used for the measurement of the proton spectra in the lumbar and thoracic part of the spine of a patient with breast cancer without known skeletal metastases. The bone marrow fat/water ratios were evaluated in the same location before and after chemotherapy treatment. The results were corrected for relaxation effects. The fat/water ratios showed a significant increase as a consequence of the bone marrow degradation process due to chemotherapy. The proposed spectroscopic imaging technique offers rapid acquisition of proton spectra from large volumes of the vertebral bodies.

Adipose Tissue↗

Endoanal ultrasound or magnetic resonance imaging for preoperative assessment of anal fistula: a comparative study.

OBJECTIVE: To compare endoanal ultrasound (EUS) with a 10-MHz probe vs. bodycoil magnetic resonance imaging (MRI) in the preoperative evaluation of anal fistula. SUBJECTS AND METHODS: 23 patients with fistula in the anal region underwent preoperative 0.5 T bodycoil MRI and 10 MHz EUS which included probing in 6 patients. The results of the EUS and MRI were compared against the surgical findings as a reference method. RESULTS: In classification of the primary tract there was agreement between EUS and surgical findings in 14 (61%) and between MRI and surgery in 11 (48%). Concerning the presence of an internal opening the corresponding figures were 17 (74%) and 10 (43%) and in judging the presence of an extension or an abscess 15 (65%) vs. 11 (48%), respectively. In three out of eight patients with nonhealing or recurrence after surgery preoperative imaging had shown an extension and/or an abscess that was not identified by the surgeon. CONCLUSION: EUS, sometimes complemented with probing, is well comparable to bodycoil MRI in classifying and describing the topography of an anal fistula.

Journal Article↗

First-pass myocardial perfusion MR imaging with outer-volume suppression and the intravascular contrast agent NC100150 injection: preliminary results in eight patients.

The authors evaluated the feasibility of combining single-shot T2-weighted turbo spin-echo magnetic resonance (MR) imaging and first-pass myocardial perfusion MR imaging with an intravascular ultrasmall superparamagnetic iron oxide (USPIO) contrast agent, NC100150 Injection (3 mg of iron per kilogram of body weight). Eight patients with coronary vessel disease underwent T2-weighted turbo spin-echo MR imaging (in-plane resolution, 1-2 mm) during the first pass of the USPIO contrast agent. The mean decrease in signal intensity in myocardium perfused by a nonstenotic coronary artery was 59% +/- 13 (SD) (P < .012) This method is feasible for imaging of myocardial perfusion.

Adult↗

Diagnosis of a patient with oncogenic osteomalacia using a phosphate uptake bioassay of serum and magnetic resonance imaging.

A previously healthy man with no family history of fractures presented with muscle pain, back pain and height loss. Investigations revealed hypophosphataemia, phosphaturia, undetectable serum 1,25-dihydroxyvitamin D and severe osteomalacia on bone biopsy, suggestive of a diagnosis of oncogenic osteomalacia. Thorough physical examination did not locate a tumour. Support for the diagnosis was obtained by detection of phosphate uptake inhibitory activity in a blinded sample of the patient's serum using a renal cell bioassay. On the basis of detection of this bioactivity, a total body magnetic resonance (MR) examination was performed. A small tumour was located in the right leg. Removal of the tumour resulted in the rapid reversal of symptoms and the abnormal biochemistry typical of oncogenic osteomalacia. Inhibitory activity was also demonstrated using the bioassay in serum from two other patients with confirmed or presumptive oncogenic osteomalacia, but not in serum from two patients with hypophosphataemia of other origin. This is the first case to be reported in which the diagnosis of oncogenic osteomalacia was assisted by demonstration of inhibitory activity of the patient's serum in a renal cell phosphate bioassay that provided an impetus for total body MR imaging.

Adult↗

Evaluation of nonperfused myocardial ischemia with MRI and an intravascular USPIO contrast agent in an ex vivo pig model.

The ultrasmall superparamagnetic iron oxide (USPIO) preparation NC100150 Injection (Clariscan; Nycomed Imaging, Oslo, Norway) was tested for its ability to delineate nonperfused myocardium under steady-state conditions. An experimental animal model of focal myocardial ischemia induced by ligation of the distal part of the left anterior descending artery was used. The contrast agent was administered in four doses: 0, 4, 8, and 12 mg Fe/kg body weight. Magnetic resonance examination ex vivo, including T1-, T2-, and T2*-weighted sequences, was performed. Nonperfused myocardium was determined by fluorescein. The best delineation of nonperfused myocardium was found with a T1-weighted inversion recovery/turbo spin-echo sequence and doses of 4 and 8 mg Fe/kg body weight, where 95% of the volume was discernible at the dose of 4 mg Fe/kg body weight. The results suggest that steady-state imaging by T1-weighted sequence with the use of NC100150 Injection to delineate nonperfused myocardium is feasible. J. Magn. Reson. Imaging 2000;12:866-872.

Animals↗

Gadolinium-enhanced magnetic resonance angiography, digital subtraction angiography and duplex of the iliac arteries compared with intra-arterial pressure gradient measurements.

PURPOSE: to compare gadolinium-enhanced magnetic resonance angiography (Gd-MRA), digital subtraction angiography (DSA) and duplex of the iliac arteries with intra-arterial pressure gradient measurement as the reference method. MATERIALS AND METHODS: Gd-MRA, DSA and duplex examinations of the iliac arteries were performed in 30 patients (60 arteries) with lower-limb arterial occlusive disease. In 29 arteries, pressure measurements were made (n=25) or the artery was found to be occluded on catheterisation (n=4). An aortofemoral peak systolic pressure gradient of 20 mmHg or more was regarded as haemodynamically significant. Stenoses with a diameter reduction of 50% or more on MRA or DSA, or an increase in peak systolic velocity greater than 150% (duplex) were considered significant. MRA examinations were evaluated by means of maximum intensity projections (MRA-MIP) and using source images and curved multiplanar reconstruction (MRA-MPR). RESULTS: the sensitivity (specificity) for a significant iliac artery stenosis were 81% (75%) for MRA-MIP, 76% (75%) for MRA-MPR, 86% (88%) for DSA, and 72% (88%) for duplex. CONCLUSION: with intra-arterial pressure measurements as the reference method, similar results were achieved with Gd-MRA, DSA and duplex concerning the detection of haemodynamically significant iliac artery stenoses. The use of source images and multiplanar reconstructions resulted in higher accuracy for the detection of occlusions.

Aged↗