A fit method for the determination of inherent filtration with diagnostic x-ray units.

A method for the determination of total inherent filtration for clinical x-ray units using attenuation curves was devised. A model for the calculation of x-ray spectra is used to calculate kerma values which are then adjusted to the experimental data in minimizing the sum of the squared relative differences in kerma using a modified simplex fit process. The model considers tube voltage, voltage ripple, anode angle and additional filters. Fit parameters are the thickness of an additional inherent Al filter and a general normalization factor. Nineteen sets of measurements including attenuation data for three tube voltages and five Al-filter settings each were obtained. Relative differences of experimental and calculated kerma using the data for the additional filter thickness are within a range of -7.6% to 6.4%. Quality curves, i.e. the relationship of additional filtration to HVL, are often used to determine filtration but the results show that standard quality curves do not reflect the variety of conditions encountered in practice. To relate the thickness of the additional filter to the condition of the anode surface, the data fits were also made using tungsten as the filter material. These fits gave an identical fit quality compared to aluminium with a tungsten filter thickness of 2.12-8.21 microm which is within the range of the additional absorbing layers determined for rough anodes.

Algorithms↗

The FLUKA code: new developments and application to 1 GeV/n iron beams.

The modeling of ion transport and interactions in matter is a subject of growing interest, driven by the continuous increase of possible application fields. These include hadron therapy, dosimetry, and space missions, but there are also several issues involving fundamental research, accelerator physics, and cosmic ray physics, where a reliable description of heavy ion induced cascades is important. In the present work, the capabilities of the FLUKA code for ion beams will be briefly recalled and some recent developments presented. Applications of the code to the simulation of therapeutic carbon, nitrogen and oxygen ion beams, and of iron beams, which are of direct interest for space mission related experiments, will be also presented together with interesting consideration relative to the evaluation of dosimetric quantities. Both applications involve ion beams in the AGeV range.

Carbon↗

Dose-volume histograms based on serial intravascular ultrasound: a calculation model for radioactive stents.

BACKGROUND AND PURPOSE: Radioactive stents are under investigation for reduction of coronary restenosis. However, the actual dose delivered to specific parts of the coronary artery wall based on the individual vessel anatomy has not been determined so far. Dose-volume histograms (DVHs) permit an estimation of the actual dose absorbed by the target volume. We present a method to calculate DVHs based on intravascular ultrasound (IVUS) measurements to determine the dose distribution within the vessel wall. MATERIALS AND METHODS: Ten patients were studied by intravascular ultrasound after radioactive stenting (BX Stent, P-32, 15-mm length) to obtain tomographic cross-sections of the treated segments. We developed a computer algorithm using the actual dose distribution of the stent to calculate differential and cumulative DVHs. The minimal target dose, the mean target dose, the minimal doses delivered to 10 and 90% of the adventitia (DV10, DV90), and the percentage of volume receiving a reference dose at 0.5 mm from the stent surface cumulated over 28 days were derived from the DVH plots. Results were expressed as mean+/-SD. RESULTS: The mean activity of the stents was 438+/-140 kBq at implantation. The mean reference dose was 111+/-35 Gy, whereas the calculated mean target dose within the adventitia along the stent was 68+/-20 Gy. On average, DV90 and DV10 were 33+/-9 Gy and 117+/-41 Gy, respectively. Expanding the target volume to include 2.5-mm-long segments at the proximal and distal ends of the stent, the calculated mean target dose decreased to 55+/-17 Gy, and DV 90 and DV 10 were 6.4+/-2.4 Gy and 107+/-36 Gy, respectively. CONCLUSIONS: The assessment of DVHs seems in principle to be a valuable tool for both prospective and retrospective analysis of dose-distribution of radioactive stents. It may provide the basis to adapt treatment planning in coronary brachytherapy to the common standards of radiotherapy.

Aged↗

The use of a high-purity germanium detector for routine measurements of 125I in radiation workers.

A high-purity germanium detector was calibrated for the assessment of 125I uptake in the thyroid gland of radiation workers. A cylindrical water phantom (perspex walls) with high flexibility for position and size of the thyroid was constructed. Within a massive shielding chamber built for a whole-body counter, an activity of 2.2 Bq was detectable (MDA). This is well below the very restrictive limiting value of 20 Bq for inhalation specified by Austrian law. An activity of 128 Bq was measured with a statistical uncertainty of 5% in a counting period of 10 min. Various parameters influencing the result are investigated as well as the performance of two other measurement geometries outside the shielding chamber.

Gamma Rays↗