[Clinical aspects of image quality and doses in gated pulsed imaging].

PURPOSE: The relations between image quality in last image hold images and dose in grid controlled fluoroscopy in comparison to the continuous mode need to be characterised and recommendations for the clinical application of this technique should be given. MATERIAL AND METHODS: Spatial resolution, signal-noise ratio and, contrast-detail visibility were evaluated by phantom measurements in grid controlled pulsed and continuous fluoroscopy. Dose was measured at the image intensifier entrance. Image quality of last image hold (LIH) images of clinical examinations was graded in relation to single shot exposures. RESULTS: Signal-noise ratio and contrast-detail visibility depend on the dose per puls. Spatial resolution and contrast-detail visibility in grid controlled fluoroscopy are superior than to in the continuous mode. Image quality of the LIH images from the grid controlled fluoroscopy was improved. Radiation exposure could be reduced to 10-46%. CONCLUSIONS: Combinations of puls-dose and -frequency are recommended for achieving extensive dose reduction and improved image quality of LIH images.

Diagnostic Imaging↗

[Initial experiences with pulsed fluoroscopy on a multifunctional fluoroscopic unit].

PURPOSE: Comparison of radiation doses in pulsed and continuous fluoroscopy to quantify the dose reduction by pulsed fluoroscopy. Further, the applicability of pulsed fluoroscopy in clinical routine has been evaluated. MATERIALS AND METHODS: In a human pelvic phantom, the radiation dose (skin entry dose in cGycm2) was measured at two pulses per second (pps), 3 pps, 6 pps, 12 pps and continuous fluoroscopy mode, respectively, using image-intensifier entries of 38 cm, 25 cm, and 17 cm. 300 examinations were carried out, and the results of the different fluoroscopy modes were registered. RESULTS: Dose reduction depends on the image-intensifier entry. Compared to the radiation dose in continuous fluoroscopy, with 12 pps fluoroscopy the radiation dose can be reduced at a minimum of 51%, with 6 pps fluoroscopy to 40%, with 3 pps fluoroscopy to 20%, and with 2 pps fluoroscopy to a minimum of 14.5%. Clinical routine has shown that 78% of all examinations can be performed with 2 or 3 pps fluoroscopy mode. In 12.7% of the cases pulsed fluoroscopy of diverse frequencies was used, in an additional 2% combined with continuous fluoroscopy. Exclusively, continuous fluoroscopy has been employed in 2% of the cases. CONCLUSIONS: Using pulsed fluoroscopy, an 80% reduction of the radiation dose compared to continuous fluoroscopy is possible. About 96% of all examinations can be performed with pulsed fluoroscopy of different pulse rate and without using continuous fluoroscopy.

Diagnostic Tests, Routine↗

Resolution of stereoisomers of dipeptides by gas chromatography on Chirasil-Val.

Several dipeptides have been separated into stereoisomers (enantiomers, diastereomers, sequential isomers) by gas chromatography on Chirasil-Val. Sufficiently volatile N-trifluoroacetyl dipeptide methyl esters were formed at ambient temperature, thus avoiding racemization (or epimerization, respectively, and cleavage of the peptide bond. This method is suitable for ascertaining the stereoisomeric composition of dipeptides in biological samples.

Chromatography, Gas↗