PubMed Health⌕ Search

Biomedical subjects

H Anetzberger

Publications and source records attributed to H Anetzberger.

At least 19 recordsLinked to original sources

Coracoid tip position on frontal radiographs of the shoulder: a predictor of common shoulder pathologies?

The coracoacromial arch is a static anterior-superior stabilizer of the humeral head. Thus coracoacromial arch inclination, which varies depending on coracoid tip position, may be related to shoulder pathologies. Therefore, we retrospectively analysed coracoid tip positions in the true anterior posterior view of different shoulder pathologies: reference shoulders (n=27), shoulders with rotator cuff tear (supraspinatus tear n=29; subscapularis tear n=21) and shoulders with anterior glenohumeral instability (traumatic n=17; atraumatic n=14). In supraspinatus tear shoulders, the coracoid tip projected onto inferior glenoid half in 86% of cases (type I coracoid), extending more inferiorly compared with reference group (p=0.0002) or subscapularis tear shoulders (p<0.0001). In contrast, 78% of cases with subscapularis tear show the coracoid tip projected onto the superior glenoid half (type II coracoid). Atraumatic glenohumeral instabilities had a more superior coracoid tip position than traumatic instabilities (p=0.04), but no differences were observed on basis of coracoid type or in comparison with normal controls. We conclude that coracoid tip position is highly variable. Since type I coracoids are predominant in shoulders with supraspinatus tears and type II coracoids in shoulders with subscapularis tears, coracoid tip position may thus provide a simple diagnostic complement for a probable site of rotator cuff tears.

Adolescent↗

Microspheres accurately predict regional bone blood flow.

Even though the microsphere method frequently is used to determinate bone blood flow, validation of this technique for bone blood flow measurement is incomplete. The method is based on the principle that injected microspheres are distributed with the arterial blood and trapped in the capillaries because of their diameter (15 microm). The number of spheres lodged in an organ is proportional to its blood flow. The number of radioactive or fluorescent microspheres in a specific organ is determined indirectly by measuring radioactivity or fluorescence intensity in the organ. In this study the reliability and precision of the microsphere method for determining bone blood flow was established using radioactive and fluorescent microspheres. Six female, anesthetized New Zealand rabbits received left ventricular injections of pairs of fluorescent and/or radioactive microspheres. The humerus, femur, and tibia were dissected in a standardized manner and blood flow was determined in each sample. Comparison of relative blood flow values showed an excellent correlation between radioactive and fluorescent microspheres. The percentage difference and variation between two simultaneously injected sets of microspheres was minimal for radioactive microspheres (0.8% +/- 9.6%) and for fluorescent microspheres (0.2% +/- 11.4%). Regional bone blood flow in different regions of the femur, tibia, or humerus ranged from 2.2-28.1 mL/minute/100 g, but there was no significant difference between right and left bone samples of the same region after repeated measurement. Radioactive and fluorescent microspheres allow precise determination of regional bone blood flow.

Animals↗

Fluorescent microspheres are reliable for serial bone blood flow measurements.

The fluorescent microsphere method is one of the current techniques to determine regional blood flow in various organs. The purpose of this study was to examine the suitability of fluorescent microspheres for serial measurement of regional bone blood flow. Six anesthetized female New Zealand rabbits received five left ventricular injections of fluorescent microspheres in 20-minute intervals. To test the precision of the measurement two types of fluorescent microspheres were injected simultaneously at the first and last injections. Blood flow was calculated in the kidneys, lungs, brain, femurs, and tibias after measuring the fluorescence intensity in each reference blood and tissue sample. Comparison of blood-flow values obtained by simultaneously injected microspheres showed an excellent correlation and a minimal percentage difference at the first and last injections, indicating valid measurements of regional bone blood flow. No significant differences were observed when comparing blood flow in the corresponding regions of bones on the right side and left side. Mean blood flow in the femur and tibia significantly increased at the fourth injection whereas flow distribution within the femur and tibia essentially remained unchanged throughout the experiment. Comparison of blood flow values obtained by simultaneously injected microspheres showed moderate agreement for the kidneys and lungs at the last injections. Because this finding might be attributable to disturbances of microcirculation caused by accumulation of spheres in high-flow organs, the increase in regional bone blood flow observed in our experiments has to be interpreted carefully. This study showed that bone blood flow can be determined reliably in anesthetized rabbits by as many as three serial injections of fluorescent microspheres.

Animals↗

Medium to long-term results with the cementless threaded Acetabular Munich II type cup.

Compared to pressfit cups, little information exists about the results of screwed cups in hip arthroplasty. 51 cementless or hybrid (cemented stem) primary total hip replacements with a cementless corundium blasted titaniumn alloy threaded Aesculap Munich II type cup were examined with a mean follow up of 7.9 years. 23 of the patients were male and 28 patients were female. From these cups 22 were implanted on the right side and 29 on the left. The results were compared to 53 patients (28 male, 25 female, 29 right side, 24 left side) with the threaded Aesculap Munich I type cup, that has a smooth surface and a direct contact of bone with the polyethylene inlay. The mean follow up ws 10.2 years. The early and medium to long-term clinical and radiographic results show an encouraging improvement of the Merle d'Aubigné Score of the type II cup compared to the type I cup. Two of the Aesculap type Munich II cups had to be revised; four showed radiologic signs of loosening. In conclusion, the threaded Aesculap cup type Munich II seems to be a decisive advance in the development of threaded acetabular hip cups. The intermediate results exceed those from smooth-surface screwed rings and compare favourably with those from cemented cups and with those from cementless press-fit metal-backed cups.

Acetabulum↗

Fluorescent microsphere method is suitable for chronic bone blood flow measurement: a long-term study after meniscectomy in rabbits.

The fluorescent microsphere (FM) method is considered a reliable technique to determine regional bone blood flow (RBBF) in acute experiments. In this study, we verified the accuracy and validity of this technique for measurement of RBBF in a long-term experiment and examined RBBF after meniscectomy. Twenty-four anesthetized female New Zealand white rabbits (3 groups, each n = 8) received consecutive left ventricular injections of FM in defined time intervals after meniscectomy: group 1 from preoperation to 3 wk postoperation; group 2 from 3 to 7 wk postoperation; and group 3 from 7 to 11 wk postoperation. To test the precision of the FM method, two FM species were injected simultaneously at the first and last measurement. After the experiment, humeri, femora, tibiae, and reference organs (kidney, lung, brain) were removed and dissected according to standardized protocols. Fluorescence was determined in each reference blood and tissue sample, and blood flow values were calculated. Blood flow in kidney, lung, and brain revealed no significant difference between right and left side and remained unchanged during the observation period, thus excluding errors due to shunting and dislodging of spheres in our experiments. Comparison of relative bone blood flow values obtained by simultaneously injected FM showed an excellent correlation at the first and last injection, indicating valid RBBF measurements in long-term experiments. We found a significant increase in RBBF 3 wk after meniscectomy in the right tibial condyles compared with the nonoperated left side. Similar changes were found in the femoral condyles. RBBF in other regions of tibia, femur, and humerus revealed no significant differences between right- and left-sided bone samples of the same region. Our results demonstrate that the FM method is valid for measuring RBBF in long-term experiments. In addition, we were able to demonstrate that meniscectomy leads to an increase in RBBF in the tibial condyles at a very early stage. This increase might be caused by stress-induced alterations of the subchondral bone.

Animals↗

Direct assessment and distribution of regional portal blood flow in the pig by means of fluorescent microspheres.

Measurement of regional organ blood flow by means of fluorescent microspheres (FM) is an accepted method. However, determination of regional portal blood flow (RPBF) cannot be performed by microspheres owing to the entrapment of the spheres in the upstream capillary bed of the splanchnic organs. We hypothesized that an adequate experimental setting would enable us to measure RPBF by means of FM and to analyze its distribution within the pig liver. A mixing chamber for the injection of FM was developed, and its capability to distribute FM homogeneously in the blood was evaluated in vitro. The chamber was implanted into the portal vein of six anesthetized pigs (23.5 +/- 2.9 kg body wt). Three consecutive, simultaneous injections of FM of two different colors into the chamber were performed. Reference portal blood samples were collected by means of a Harvard pump. At the end of the experiment, the liver was explanted and fixed in formalin before dissection. FM were isolated from the tissue samples by an automated process, and fluorescence intensity was determined. Comparison of 5,458 single RPBF values, determined by simultaneously injected FM, revealed good agreement (bias 2.5%, precision 12.7%) and high correlation (r = 0.97, r2 = 0,95, slope = 1.04, intercept = 0.05). Median RPBF was 1.07 +/- 0.78 ml x min(-1) x g(-1). Allocation of the blood flow values to the anatomic regions of the liver revealed a significantly higher RPBF (P = 0.01) in the liver tissue located close to the diaphragm compared with the rest of the organ and a significantly lower RPBF (P = 0.01) in the left liver lobe compared with the median and right lobes. The results show that the model presented makes it possible to measure RPBF by means of FM reliably and that RPBF is distributed heterogeneously in the porcine liver.

Animals↗

Validity of fluorescent microspheres method for bone blood flow measurement during intentional arterial hypotension.

In this study, we compared bone blood flow values obtained by simultaneously injected fluorescent (FM) and radiolabeled microspheres (RM) at stepwise reduced arterial blood pressure. Ten anesthetized female New Zealand White rabbits received simultaneous left ventricular injections of FM and RM at 90, 70, and 50 mmHg mean arterial blood pressure (MAP). After the experiments, both kidneys and long bones of all four limbs were removed and dissected in a standardized manner. Radioactivity (corrected for decay, background, and spillover) and fluorescence were determined, and blood flow values were calculated. Relative blood flow values estimated for each bone sample by RM and FM were significantly correlated (r = 0.98, slope = 0.99, and intercept = 0.04 for 90 mmHg; r = 0.98, slope = 0.94, and intercept = 0.09 for 70 mmHg; r = 0.98, slope = 0.96, and intercept = 0.07 for 50 mmHg). Blood flow values (ml x min-1 x 100 g-1) of right and left bone samples determined at the different arterial blood pressures were identical. During moderate hypotension (70 mmHg MAP), blood flow in all bone samples remained unchanged compared with 90 mmHg MAP, whereas a significant decrease of bone blood flow was observed at severe hypotension (50 mmHg MAP). Our results demonstrate that the FM technique is valid for measuring bone blood flow. Differences in bone blood flow during altered hemodynamic conditions can be detected reliably. In addition, changes in bone blood flow during hypotension indicate that vasomotor control mechanisms, as well as cardiac output, play a role in setting bone blood flow.

Algorithms↗

[Dynamic palmar instability of the ulnar head].

Despite obvious clinical symptoms, dynamic, palmar instability of the ulnar head remains a diagnostic and therapeutic problem. This is demonstrated by a case of chronic, palmar instability of the ulnar head after a tear of the triangular fibrocartilage complex (TFCC). A concomitant, minimal dorsal angulation of the radius after a fracture in childhood and a general capsulo-ligamentous laxity possibly were predisposing factors. Aspects of diagnostic and therapeutic options are discussed. In our case, due to secondary arthrosis, an arthrodesis of the distal radioulnar joint combined with a stabilization of the TFCC was opted for. Although the patient is painfree and mobile, she complains of a loss of power in supination. This salvage procedure probably could have been avoided by an earlier diagnosis.

Adult↗

[The sublabral foramen. Congenital or an acquired variance?].

The sublabral foramen is considered to be a clinically asymptomatic, isolated variant of the anterior-superior capsulo-labral-complex. It may be observed during shoulder arthroscopy and may implicate problems in differential diagnosis of traumatic lesions. In an anatomic study on 89 macroscopically healthy shoulder specimens the age distribution and the incidence in relation to the varying shape of the glenoid as feasible factors of influence for a sublabral foramen (SF) were analyzed in order to elucidate the unknown pathogenesis of SF. In addition histologic sections of three SF samples were obtained. Mean age of the specimens with a sublabral foramen [n=20; 69 (37-84) years] was significantly higher (p=0.04) compared to samples without a sublabral foramen [n=69; 59 (18-94) years]. An increased incidence of a sublabral foramen in relation to a distinct shape of the glenoid could not be established although a prevalence of a glenoid with anterior notch was observed. The results indicate an age-related development of the sublabral foramen,thus in younger patients with an anterior-superior capsulolabral displacement local signs of trauma and involvement of the biceps anchor should be controlled before definitive diagnosis.

Adolescent↗

The relation between primary osteoarthritis of the trapeziometacarpal joint and supernumerary slips of the abductor pollicis longus tendon.

We have studied whether accessory abductor pollicis longus slips inserting into the thenar eminence or trapezium influence the incidence and severity of trapeziometacarpal joint osteoarthritis. The right first extensor compartment of 73 cadavers was dissected and trapeziometacarpal degeneration was graded macroscopically. The main abductor pollicis longus tendon which inserted at the metacarpal base was accompanied by supernumerary APL slips in 96% of cases. Thenar or trapezial slips occurred frequently but coexisted in only one case. The incidence of trapeziometacarpal arthritis was not influenced by the number of accessory slips or whether they inserted onto the thenar eminence or the trapezium.

Aged↗

Subchondral mineralization patterns of the glenoid after tear of the supraspinatus.

Clinical experience has shown that in many cases of rupture of the supraspinatus tendon the head of the humerus shifts upward against the acromion. This implicates alterations in the stress acting on the joint surface. Accordingly, this should be reflected by changes in the distribution of the subchondral mineralization on the glenoid. Computed tomography osteoabsorptiometry was used to evaluate the distribution patterns on the subchondral bone plate of the glenoid in 67 human shoulders. The position of the two most frequent density maxima was determined by a standard procedure. In macroscopically normal specimens (n = 24) every case had an anterosuperior density maximum and the majority (75%) also had a posterior positioned maximum. In some instances a third maximum, placed centrally (17%) or in an anteroinferior position (4%) was seen. In shoulders with a torn supraspinatus tendon (n = 43) a third density maximum frequently appeared in the center of the glenoid (42%); however, most notable was a significant change of the posterior maximum position toward central and superior. With increasing size of the tendon defect an extension of the shift of the posterior maximum (superiorly and centrally) was observed in contrast to the constant anterior maximum. The changes in the distribution of glenoid subchondral bone mineralization in shoulders with a supraspinatus tear must be regarded as a morphologic parameter for the altered long-term stress acting on the joint surface.

Aged↗

Thickness of the subchondral mineralised tissue zone (SMZ) in normal male and female and pathological human patellae.

The objective of this paper was to analyse sex differences of the thickness of the subchondral mineralised tissue zone (SMZ), and to find out whether systematic changes of SMZ thickness are associated with naturally occurring, non-full-thickness cartilage lesions of human patellae. In 32 methyl-methacrylate-embedded specimens (16 normal, 8 with focal medial, and 8 with lateral lesions) the SMZ thickness was determined, using a binocular macroscope and an image analysing system. In each case, the thickness distribution was reconstructed throughout the entire joint surface. The maximal and mean SMZ thicknesses were significantly higher in males than in females (P < 0.01). In normal patellae and those with lateral lesions, the thickness was significantly thicker laterally than medially (P < 0.05), but it was not in specimens with medial damage. Patellae with medial damage exhibited a significantly lower total mean and lateral mean (P < 0.05). A lower SMZ thickness was found directly beneath medial lesions than beneath lateral ones, but the local thickness was always in the range of that observed in normal specimens. We conclude that differences of patellar SMZ thickness exist between males and females. Naturally occurring cartilage lesions appear, however, not to be associated with local changes of SMZ thickness, but they may be associated with an altered regional distribution pattern within the joint surface.

Aged↗

[Stress osteotomy of the distal radius- and ulna metaphysis (Illarramendi procedure): an alternative treatment method in lunate necrosis].

The etiology of Kienböck's disease is still unknown. Many operative procedures, usually based on biomechanical considerations, are recommended. Based on known effects of core decompression procedures on bone, we present a technique of core decompression of the metaphysis of the distal radius and ulna (MCD) as an easy, alternative biologic treatment. Ten cases with a mean follow-up of 10.8 years are analyzed. All patients had significant postoperative pain relief and returned to their previous activities. At the time of follow-up, comparative motion of flexion-extension of the wrist averaged 74%, mean grip strength was 81% of the nonaffected side. Radiographic follow-up did not slow significant postoperative collapse of the lunate (p > 0.05). No correlation was observed between post-operative results and ulnar variance. MCD is a simple, low-risk procedure. Clinical and radiological outcome supports a theory of biologic rather than biomechanic mechanisms related to fracture healing, that stimulate regeneration of the avascular lunate and relieve symptoms. A primary vascular etiology of idiopathic avascular necrosis of the lunate seems to be likely.

Adult↗

[Acromio-humeral distance and acromial shape in 3-dimensional computerized tomography reconstruction. Side comparison in supraspinatus outlet syndrome].

Mechanical irritations of the supraspinatus tendon due to a reduction of the subacromial space are considered to be a potential cause of supraspinatus outlet syndrome. The aim of the current study was, therefore, to provide a method of improved measurement of the acromiohumeral distance and the evaluation of the acromial shape. In seven patients aged 50-60 years with unilateral supraspinatus outlet syndrome, imaging with standardized, high-resolution computed tomography (CT) was performed in order to demonstrate the acromion and the subacromial space three-dimensionally. The acromiohumeral distance was measured in three reconstructed frontal sections, and the two sides of each patient were directly compared. The acromial shape was compared with the classification of Bigliani as derived from conventional radiography. Whereas the Constant Score was found to be significantly reduced in the diseased shoulders (p < 0.01), the acromiohumeral distance was not significantly lower in three standardized frontal sections. In five cases the classification of the acromial form from the conventional radiograph was confirmed by 3D CT, whereas in two cases it was shown to be different. Our results suggest that primary or secondary changes of the acromial form can be more accurately evaluated with 3D CT than with conventional radiography. A direct comparison of the two sides in patients with supraspinatus syndrome does not suggest a reduction of acromiohumeral distance in the diseased shoulder.

Female↗

Determination of subacromial space width and inferior acromial mineralization by 3D CT. Preliminary data from patients with unilateral supraspinatus outlet syndrome.

A reduction of the subacromial space and an increased subacromial pressure have been considered to play an important role in the pathogenesis of rotator cuff lesions. The objective of the current study was to develop a CT based method for measuring the acromiohumeral distance and inferior acromial mineralization. In seven patients with unilateral rupture of the rotator cuff and two with impingement syndrome, transverse CT images were obtained at a section thickness of 1 mm with muscular relaxation in a standardized position. The bones were then reconstructed three-dimensionally, and the minimal vertical distance between the acromion and the humerus was determined in three secondary frontal images on both sides. The distribution of mineralization within the inferior surface of the acromion was assessed using CT osteoabsorptiometry. Although the Constant score was significantly reduced in the diseased shoulders, the width of the subacromial space was not routinely lower than on the contralateral side. In seven cases the maximal inferior acromial mineralization was identical in both shoulders, and in two cases it was lower on the affected side. These preliminary data suggest that with muscular relaxation no narrowing of the subacromial space can be detected in secondary frontal CT images, and that a potential increase of subacromial pressure is not high enough to cause a measurable increase in inferior acromial bone density. The method presented makes it possible to investigate the pathogenesis of the supraspinatus outlet syndrome in vivo with greater precision than has so far been possible with conventional radiography.

Acromion↗

The scapula: principles of construction and stress.

According to current generally accepted theories, analysis of the shape of a bone provides clues to the stresses acting upon it. Although many investigations have ensured that understanding of the lower limb is relatively advance, knowledge relating to the upper limb, and particularly to the scapula, is still far from complete. We have therefore endeavoured to interpret the shape of this bone morphometrically. To this end various scapular parameters have been standardised and statistically analysed, and the results examined both from the functional and the clinical points of view. Our investigation has established that, as in the case of the long bones, the form of the scapula is dependent upon both height and sex. Assessment of the architecture of the subacromial space and its possible parameters of influence have also demonstrated that the size of this space is essentially dependent upon the height of the subject and the size of the acromial and scapulospinal angles. A short distance between the acromion and the upper edge of the glenoid cavity and a small glenoid-spinal angle can be regarded from a functional point of view as factors predisposing to the development of the impingement syndrome. We have also been able to show that certain constant structural features produce an optimal distribution of the forces acting upon the scapula. In particular, the relationship of the supporting pillars (the lateral border and the spine) of this bone to one another appears to represent the expression of an ideal adaptation to the action of those forces.

Humans↗

[Lesions of the popliteus system and their significance for the stability of the knee joint].

INTRODUCTION: Stäubli postulated a clinical significance of lesions to the popliteus system because of a 95% incidence in acute and 85.7% in chronic ruptures of the cruciate ligaments. The sparse clinical literature on this topic favours conservative or operative treatment as well. OBJECTIVE OF THE STUDY: What is the significance of isolated lesions of the popliteus tendon on translational stability of the knee joint? MATERIAL AND METHODS: The popliteus tendon was severed in six sheep. One year postop. the knee joints were evaluated by means of x-ray, biomechanical testing, computed tomography osteoabsorptiometry (CTOAM) and micromorphology. RESULTS: There were no pathological findings on x-ray. The simulation of the trauma situation ex vivo showed no instability whereas increased translation and progressive loosening of secondary stabilizers was found after one year (posterior and total aptranslation, compliance index p < 0.05). The position of the density maxima of the subchondral mineralization are about the same on the operated and the non-operated knee joint. All tendons healed macroscopically, but micromorphology exhibited a persisting increase of cross-sectional areas, a low differentiated ultrastructure of the tendon and an increased cellularity (p < 0.01). CONCLUSIONS EXPERIMENTAL: 1. intraarticular, extrasynovial tendons heal spontaneously even within the synovial environment; 2. healing is defective even one year postop.; 3. the postulate of the significance of the popliteus system for the stability of the knee is proven. Clinical: 1. (isolated) lesions of the popliteus go undetected with clinical and instrumented examination; 2. conservative treatment eventually results in increased posterior translational instability; 3. this will increase strain and load on the menisci and ACL- reconstructions.

Animals↗

[Morphometry of the sub-acromial space and its clinical relevance].

Rupture of the rotator cuff is one of the commonest (30%) pathologic findings in elderly dissecting room subjects. Together with the degenerative tendopathy associated with increasing age, this is due to mechanical damage to the distal parts of the tendons or the soft tissues lying in the subacromial space between the acromion, coracoacromial ligament, coracoid process and humeral head. The object of this investigation was to examine the influence of the decisive metrical parameters of the subacromial space in the macerated scapula. For this purpose, defined distances and angles of 343 macerated human scapulae were measured by means of an image analysing system, and the results evaluated statistically. It was found that the size of the subacromial space depends, not only upon variations in the form of the acromion itself, but also upon the acromial and scapula-spine angles. Marked projection of the coracoid process, which is dependent upon both the angle between the long axis of the scapula and the root of the coracoid process and the coracoid angle, plays an important part in the development of the so-called subcoracoid impingement syndrome: a constriction of the subscapularis tendon between the coracoid process and the head of the humerus. A clinical assessment of the absolute size of the subacromial space should take into account the size of the body; but sex, age, and the side involved are of little significance.

Acromioclavicular Joint↗