PubMed Health⌕ Search

Biomedical subjects

H B Halsall

Publications and source records attributed to H B Halsall.

At least 73 records · Page 4Linked to original sources

Electrochemical investigation of hapten-antibody interactions by differential pulse polarography.

The binding of electroactively labeled estriol with estrogen-specific antibody and its subsequent displacement by unlabeled estriol have been monitored by differential pulse polarography. Estriol was found to be electro-inactive in the potential range -200 mV to -1000 mV vs a silver/silver chloride electrode. Estriol labeled in the 2 and 4 position with nitro groups was electroactive, giving two reduction waves at -422 mV and -481 mV vs a silver/silver chloride electrode. The peak current was linear with concentration over the range 60 micrograms/L to 3.7 mg/L. The addition of aliquots of estrogen-specific antibody reduced the peak current proportionately, indicating the binding of ligand to specific antibody. Subsequent addition of unlabeled estriol produced incremental increases in peak reduction current, indicating competitive and reversible binding of the two ligands for the antibody. Separation of bound from free labeled hapten was not necessary because reduction of the antibody-bound labeled estriol is attenuated at the electrode.

Antibodies, Monoclonal↗

A microcapillary assay (MASS) for macrophage migration inhibition factor.

A technically simple microassay for macrophage migration inhibition studies is described. Using simple 0.08 ml of test solution per assay, meaningful statistical analysis via multiple replicates is possible. A novel feature is that test solutions may be stored frozen in the test well until the indicating macrophages are ready for use. The assay was used to demonstrate that MIF, derived from the human lymphoid cell line RPMI 1788, eluted from Sephadex G-75 in the molecular weight range of 13,000--25,000.

Animals↗

Immunoassay by differential pulse polarography.

An immunological method based on labeling an antigen with an electroactive group detectable by differential pulse polarography has been demonstrated. Estriol labeled with mercuric acetate is electroactive, giving a reduction wave at -300 millivolts versus a standard calomel electrode. Addition of estriol antibody to 4-mercuric acetate estriol diminishes the peak current as a result of the antigen-antibody binding reaction. Separation of free-labeled estriol from antibody-bound-labeled antigen is unnecessary. The method is potentially useful as an analytical immunological technique.

Estriol↗

Simultation of gradient and band propagation in the centrifuge.

A technique is developed for simulating the behavior of both the gradient-forming solute and macromolecular bands in a centrifuge. The change with time of the density gradient due to diffusion and sedimentation of the gradient-forming solute is calculated by a finite difference method, making use of the results of earlier work on the theory of the equilibrium density gradient. Using a perturbation technique, the concentration profiles of dilute bands of macromolecules are then calculated as they sediment and diffuse through the varying supporting gradient. Results of the stimulaion techniques are compared with experiment.

Centrifugation, Density Gradient↗