PubMed Health⌕ Search

Biomedical subjects

H B Liu

Publications and source records attributed to H B Liu.

At least 19 recordsLinked to original sources

Structural selection and amorphization of small Ni-Ti bimetallic clusters.

Classical molecular dynamics simulation is used for structural thermodynamic analysis of Ni-Ti bimetallic clusters. Experimental observation for the nanoclusters synthesized by the bioreduction method is used to consolidate the conclusion. The results demonstrate that Ni-Ti nanoclusters as small as 2-3 nm are not energetically favorable for common ordered geometrical arrangements such as cuboctahedron, decahedron, and icosahedron, though they can be synthesized experimentally. For the elemental distribution, Ni and Ti tend to aggregate separately. In the cases under study, eutectic-like and Ni-core/Ti-shell structures can keep their basic shape and elemental distribution during long periods of relaxation at room temperature. For other cases such as solid solution and Ti-core/Ni-shell, the structures amorphized and the elements tend to distribute uniformly even though they are at temperatures as low as room temperature. Experimental evidence was obtained by the analysis of biosynthesized nanoparticles using transmission electron microscopy techniques. This allowed determination of the partial amorphized structures of small bimetallic particles with cubic and multiple twined-like structures.

Journal Article↗

Structural transformation of Au-Pd bimetallic nanoclusters on thermal heating and cooling: a dynamic analysis.

Classical molecular dynamics simulation is used for structural thermodynamic and dynamic analysis of Au-Pd bimetallic clusters. It is observed that the Pd-core/Au-shell structure is the most stable, and can be formed through annealing of other structures such as Au-core/Pd-shell, eutecticlike, or solid solution. Depending on the starting temperature and initial composition, three-layer icosahedral nanorod, face-centered cubic (fcc) nanorod, and fcc cluster can be obtained on slow cooling. The three-layer icosahedral nanorod structure is not as stable as the Pd-core/Au-shell decahedron; however it is more stable than the solid-solution decahedron structure up to 400 K. Our findings provide valuable insight into catalysis using Au-Pd and other similar bimetallic clusters.

Journal Article↗

Transmission electron microscopy and theoretical analysis of AuCu nanoparticles: atomic distribution and dynamic behavior.

Though the application of bimetallic nanoparticles is becoming increasingly important, the local atomistic structure of such alloyed particles, which is critical for tailoring their properties, is not yet very clearly understood. In this work, we present detailed study on the atomistic structure of Au-Cu nanoparticles so as to determine their most stable configurations and the conditions for obtaining clusters of different structural variants. The dynamic behavior of these nanoparticles upon local heating is investigated. AuCu nanoparticles are characterized by high resolution transmission electron microscopy (HRTEM) and energy filtering elemental composition mapping (EFECM), which allowed us to study the internal structure and the elemental distribution in the particles. Quantum mechanical approaches and classic molecular dynamics methods are applied to model the structure and to determine the lowest energy configurations, the corresponding electronic structures, and understand structural transition of clusters upon heating, supported by experimental evidences. Our theoretical results demonstrate only the core/shell bimetallic structure have negative heat of formation, both for decahedra and octahedral, and energetically favoring core/shell structure is with Au covering the core of Cu, whose reverse core/shell structure is not stable and may transform back at a certain temperature. Experimental evidences corroborate these structures and their structural changes upon heating, demonstrating the possibility to manipulate the structure of such bimetallic nanoparticles using extra stimulating energy, which is in accordance with the calculated coherence energy proportions between the different configurations.

Alloys↗

Neodymium nanoparticles: biosynthesis and structural analysis.

Small metallic nanoparticles of neodymium are obtained by a facile route based on the biosynthesis and the pH conditions that demonstrate the possibility of obtaining particles of 1-8 nm. The size is controlled by synthesis conditions. Smaller clusters were obtained with pH = 5, while for pH = 10 evidences of nanorods productions are found and this opens the perspective to use this rare-earth element for zero and one dimensional based applications. Using transmission electron microscopy techniques, the size distribution and structure are studied. Density functional theory-based calculations allow the determination of the lowest energy configuration, which is based on the hexagonal bulk symmetry. Theoretical models are used to simulate the high resolution transmission electron microscopy to identify the experimental image, determining that the synthesized nanoparticles reach the lowest energy hexagonal configurations.

Computer Simulation↗

Synthesis and characterization of Mn quantum dots by bioreduction with water hyacinth.

The bio-reduction method is reported as a part of a complimentary self-sustained technology, where bioremediation and metal particle production are related. The use of the characterization methods in this self sustainable technique open the expectative to be used for several other elements and with other plants, which will be discussed. However, the particular case of Mn nanoparticles involves an important option to generate nanoparticles in the range of 1-4 nanometers with a well controlled size and with a structure based on an fcc-like geometry for the smallest clusters and with more complex arrays for cluster greater than four shells, which involves magnetic moments significantly related to their atomistic configuration. At the same time, the use of the characterization methods establishes the dependence of the nanoparticle's size on the pH conditions used during the synthesis; small clusters in the range of 1-2 nm were generated using pH=5, and it was shown that for the smallest aggregates, simple polyhedron shapes are stable.

Biomass↗

Thiazolidinediones inhibit TNFalpha induction of PAI-1 independent of PPARgamma activation.

Increased plasminogen activator inhibitor type 1 (PAI-1) levels are observed in endothelial cells stimulated by tumour necrosis factor alpha (TNFalpha). Thiazolidinediones (TZDs) may inhibit elevated endothelial cell PAI-1 accounting, in part, for the putative atheroprotective effects of TZDs. In an endothelial cell line, Rosiglitazone (RG) and Pioglitazone (PG) inhibited induction of PAI-1 by TNFalpha. The specific peroxisome proliferator-activated receptor gamma (PPARgamma) inhibitor, SR-202, failed to modulate this effect. RG also inhibited the effect of TNFalpha on a reporter gene construct harbouring the proximal PAI-1 promoter and PAI-1 mRNA in cells co-transfected with a dominant-negative PPARgamma construct. RG and PG attenuated TNFalpha-mediated induction of trans-acting factor(s) Nur77/Nurr1 and binding of nuclear proteins (NP) to the cis-acting element (NBRE). SR-202 failed to modulate these effects. The observations suggest TZDs inhibit TNFalpha-mediated PAI-1 induction independent of inducible PPARgamma activation and this may involve in the modulation of Nur77/Nurr1 expression and NP binding to the PAI-1 NBRE.

Cell Line↗

Preparation of AlFe nanoparticles by mechanical alloyed technique.

Small metallic particles (1-3 nm) have been obtained using mechanical alloying techniques. Analytical techniques such as scanning electron microscopy have been used for the morphological and chemical characterization of the AlFe alloyed powders. B, Ni and Ti have been explored as reinforced elements to the initial AlFe mixture. X-ray diffraction patterns and transmission electron microscopy (TEM) techniques have been employed for the structural characterization of the small metallic particles. Theoretical simulations based on molecular dynamics have been used to interpret some of the experimental structural results. Furthermore, theoretical simulations of HREM images based on the dynamical theory of electron diffraction have also been obtained and comparisons with the experimental results have been carried out. The complementary analyses determined that the produced clusters are basically AlFe alloyed nanoparticles immersed in a matrix and with multiple defected structures.

Aluminum↗

Sulfoglycolipid from the marine brown alga Sargassum hemiphylum.

One kinds of glycolipid (SBI) have been isolated from the marine brown alga Sargassum hemiphyllum (Turn.) Ag. The structures of SBI have been determined as the sodium salt of 1-0-acyl-3-0-(6'-sulfo-alpha-D-quinovopyrannosyl) glycerol (acyl: tetradecanoyl, pentadecanoyl, 11-hexadecenoyl, hexadecanoyl, 10,13-octadecadienoyl, 9-octade cenoyl, 15-metylheptadecanoyl and 11-eicosenoyl 17: 1.5: 19: 153: 1: 19: 1: 2) on the basis of chemical and spectral evidence and GC-MS analysis, respectively. Four constituents of the SBI were new compounds [the sodium salt of 1-0-(11"-hexadecenoyl)-3-0-(6'-sulfo-alpha-D-quinovopyrannosyl) glycerol, the sodium salt of 1-0-(10",13"-octadecadienoyl)-3-0-(6'-sulfo-alpha-D-quinovopyrannosyl) glycerol, and the sodium salt of 1-0-(15"-metylhexadecenoyl)-3-0-(6'-sulfo-alpha-D-quinovopyrannosyl) glycerol, and the sodium salt of 1-0-(11"-eicosenoyl)-3-0-(6'-sulfo-alpha-D-quinovopyrannosyl) glycerol]. All compounds were isolated from marine brown alga for the first time.

China↗

[Prevalence of mutants in the determinant region of hepatitis B surface antigen among Chinese carriers after receiving only active postexposure immunoprophylaxis].

OBJECTIVE: To determine the frequency of hepatitis B surface antigen (HBsAg) mutations in the alpha determinant region among children who developed chronic hepatitis B virus (HBV) infection after receiving only active postexposure immunoprophylaxis. METHODS: HBsAg mutations were determined by PCR-directed nucleotide sequencing and sequence-specific solid-phase PCR analysis(SS-SPPCR) for 97 Chinese carrier cases after hepatitis B vaccination, for 88 children born aged women controls, and for 95 population based children controls. RESULTS: Prevalence of amino acid substitutions as detected by direct sequencing among carrier cases, women controls, and children controls were 30.9%, 10.2%, and 5.3%, respectively. The most frequent amino acid substitutions observed were at residues 145, 126, and 133. However, there was no difference in the prevalence of 145 and 126 amino acid mutants as detected by a sensitive SS-SPPCR method between carrier cases and controls. The prevalence of 145 Arg and 145 Ala mutants that were detected by SS-SPPCR was 39.2%, 33.0% and 32.6% among carrier cases, women controls, and children controls, respectively. The total odds ratio was 5.41 for mutants detected by direct sequencing. Odds ratio were 34.55 and 33.39 among adw2 subtype and genotype B subjects for mutants detected by direct sequencing, respectively. CONCLUSIONS: The results show that hepatitis B virus mutants in the determinant are fairly consistent observed but without immune selective pressures; HBV variant strains may pre-existent as minor quasispecies. The prevalence of mutants is related to HBV subtypes and genotypes.

Adolescent↗

Fission converter and metal-oxide-semiconductor field effect transistor study of thermal neutron flux distribution in an epithermal neutron therapy beam.

The depth distribution of the thermal neutron flux is a major factor in boron neutron capture therapy (BNCT) in determining the efficiency of cell sterilization. In this paper the fission detector method is developed and applied to measure the in-phantom thermal neutron flux depth distribution. Advantages of the fission detector include small size, direct measurement of thermal neutron flux in a mixed radiation field of BNCT beam, self-calibration, and the possibility of on-line measurement. The measurements were performed at epithermal a BNCT facility. The experimental results were compared with the thermal neutron flux calculated by the Monte Carlo method and found to be in good agreement.

Biophysical Phenomena↗

Boron neutron-capture therapy (BNCT) for glioblastoma multiforme (GBM) using the epithermal neutron beam at the Brookhaven National Laboratory.

OBJECTIVE: Boron neutron-capture therapy (BNCT) is a binary form of radiation therapy based on the nuclear reactions that occur when boron (10B) is exposed to thermal neutrons. Preclinical studies have demonstrated the therapeutic efficacy of p-boronophenylalanine (BPA)-based BNCT. The objectives of the Phase I/II trial were to study the feasibility and safety of single-fraction BNCT in patients with GBM. MATERIALS AND METHODS: The trial design required (a) a BPA biodistribution study performed at the time of craniotomy; and (b) BNCT within approximately 4 weeks of the biodistribution study. From September 1994 to July 1995, 10 patients were treated. For biodistribution, patients received a 2-hour intravenous (i.v.) infusion of BPA-fructose complex (BPA-F). Blood samples, taken during and after infusion, and multiple tissue samples collected during surgical debulking were analyzed for 10B concentration. For BNCT, all patients received a dose of 250 mg BPA/kg administered by a 2-hour i.v. infusion of BPA-F, followed by neutron beam irradiation at the Brookhaven Medical Research Reactor (BMRR). The average blood 10B concentrations measured before and during treatment were used to calculate the time of reactor irradiation that would deliver the prescribed dose. RESULTS: 10B concentrations in specimens of scalp and tumor were higher than in blood by factors of approximately 1.5 and approximately 3.5, respectively. The 10B concentration in the normal brain was < or = that in the blood; however, for purposes of estimating radiation doses to normal brain endothelium, it was always assumed to be equal to blood. BNCT doses are expressed as gray-equivalent (Gy-Eq), which is the sum of the various physical dose components multiplied to appropriate biologic effectiveness factors. The dose to a 1-cm3 volume where the thermal flux reached a maximum was 10.6 +/- 0.3 Gy-Eq in 9 patients and 13.8 Gy-Eq in 1 patient. The minimum dose in tumor ranged from 20 to 32.3 Gy-Eq. The minimum dose in the target volume (tumor plus 2 cm margin) ranged from 7.8 to 16.2 Gy-Eq. Dose to scalp ranged from 10 to 16 Gy-Eq. All patients experienced in-field alopecia. No CNS toxicity attributed to BNCT was observed. The median time to local disease progression following BNCT was 6 months (range 2.7 to 9.0). The median time to local disease progression was longer in patients who received a higher tumor dose. The median survival time from diagnosis was 13.5 months. CONCLUSION: It is feasible to safely deliver a single fraction of BPA-based BNCT. At the dose prescribed, the patients did not experience any morbidity. To further evaluate the therapeutic efficacy of BNCT, a dose-escalation study delivering a minimum target volume dose of 17 Gy-Eq is in progress.

Aged↗

The requirements and development of neutron beams for neutron capture therapy of brain cancer.

One of the two overriding conditions for successful BNCT is that there must be a sufficient number of thermal neutrons delivered to each of the boronated cells in the tumour bed (target volume). Despite the poor experience with BNCT in the USA some 40 years ago, the continued apparent success of BNCT in Japan since 1968, lead indirectly to the re-start of clinical trials on BNCT in 1994 at both Brookhaven and MIT. Similar trials will start soon at Petten in Europe. At other centres worldwide, many neutron beam designs are being proposed with either thermal or epithermal neutrons, emanating predominantly from nuclear research reactors. It is apparent that whilst the success of BNCT depends on a suitable neutron beam, there is a diversity in available designs, as well as each proposed type of neutron source, with consequently different characteristics of the emergent neutron beam. The paper presents the historical development of neutron beams used for BNCT, addresses the requirements on the types of beams, describes some of the existing designs and other proposals elsewhere and lastly, considers the broader requirements in designing NCT facilities. The focus of the paper is on treatment of brain cancer, neutron beam requirements for other types of cancer may vary.

Boron Neutron Capture Therapy↗

Boron neutron capture therapy for glioblastoma multiforme using p-boronophenylalanine and epithermal neutrons: trial design and early clinical results.

A Phase I/II clinical trial of boron neutron capture therapy (BNCT) for glioblastoma multiforme is underway using the amino acid analog p-boronophenylalanine (BPA) and the epithermal neutron beam at the Brook-haven Medical Research Reactor. Biodistribution studies were carried out in 18 patients at the time of craniotomy using an i.v. infusion of BPA, solubilized as a fructose complex (BPA-F). There were no toxic effects related to the BPA-F administration at doses of 130, 170, 210, or 250 mg BPA/kg body weight. The tumor/ blood, brain/blood and scalp/blood boron concentration ratios were approximately 3.5:1, 1:1 and 1.5:1, respectively. Ten patients have received BNCT following 2-hr infusions of 250 mg BPA/kg body weight. The average boron concentration in the blood during the irradiation was 13.0 +/- 1.5 micrograms 10B/g. The prescribed maximum dose to normal brain (1 cm3 volume) was 10.5 photon-equivalent Gy (Gy-Eq). Estimated maximum and minimum doses (mean +/- sd, n = 10) to the tumor volume were 52.6 +/- 4.9 Gy-Eq (range: 64.4-47.6) and 25.2 +/- 4.2 Gy-Eq (range: 32.3-20.0), respectively). The estimated minimum dose to the target volume (tumor +2 cm margin) was 12.3 +/- 2.7 Gy-Eq (range: 16.2-7.8). There were no adverse effects on normal brain. The scalp showed mild erythema, followed by epilation in the 8 cm diameter field. Four patients developed recurrent tumor, apparently in the lower dose (deeper) regions of the target volume, at post-BNCT intervals of 7,5,3.5 and 3 months, respectively. The remaining patients have had less than 4 months of post-BNCT follow-up. BNCT, at this starting dose level, appears safe. Plans are underway to begin the dose escalation phase of this protocol.

Adult↗

Calibration of the delayed-gamma neutron activation facility.

The delayed-gamma neutron activation facility at Brookhaven National Laboratory was originally calibrated using an anthropomorphic hollow phantom filled with solutions containing predetermined amounts of Ca. However, 99% of the total Ca in the human body is not homogeneously distributed but contained within the skeleton. Recently, an artificial skeleton was designed, constructed, and placed in a bottle phantom to better represent the Ca distribution in the human body. Neutron activation measurements of an anthropomorphic and a bottle (with no skeleton) phantom demonstrate that the difference in size and shape between the two phantoms changes the total body calcium results by less than 1%. To test the artificial skeleton, two small polyethylene jerry-can phantoms were made, one with a femur from a cadaver and one with an artificial bone in exactly the same geometry. The femur was ashed following the neutron activation measurements for chemical analysis of Ca. Results indicate that the artificial bone closely simulates the real bone in neutron activation analysis and provides accurate calibration for Ca measurements. Therefore, the calibration of the delayed-gamma neutron activation system is now based on the new bottle phantom containing an artificial skeleton. This change has improved the accuracy of measurement for total body calcium. Also, the simple geometry of this phantom and the artificial skeleton allows us to simulate the neutron activation process using a Monte Carlo code, which enables us to calibrate the system for human subjects larger and smaller than the phantoms used as standards.

Body Composition↗

An improved neutron collimator for brain tumor irradiations in clinical boron neutron capture therapy.

To improve beam penetration into a head allowing the treatment of deeper seated tumors, two neutron collimators were built sequentially and tested for use in the clinical boron neutron capture therapy (BNCT) program at the epithermal neutron irradiation facility of the Brookhaven Medical Research Reactor. The collimators were constructed from lithium-impregnated polyethylene, which comprises Li2CO3 powder (approximately 93% enriched isotopic 6Li) uniformly dispersed in polyethylene to a total 6Li content of 7.0 wt. %. The first collimator is 7.6 cm thick with a conical cavity 16 cm in diameter on the reactor core side tapering to 8 cm facing the patient's head. The second collimator is 15.2 cm thick with a conical cavity 20 cm in diameter tapering to 12 cm. A clinical trial of BNCT for patients with malignant brain tumors is underway using the first collimator. Results of phantom dosimetry and Monte Carlo computations indicate that the new 15.2 cm thick collimator will improve the neutron beam penetration. Thus, the second collimator was made and will be used in an upcoming clinical trial. In-air and in-phantom mixed-field dosimetric measurements were compared to Monte Carlo computations for both collimators. The deeper penetration is achieved but at a sacrifice in beam intensity. In this report, a performance comparison of both collimators regarding various fluence rate and absorbed dose distributions in a head model is presented and discussed.

Biophysical Phenomena↗

Physical and biological doses produced from neutron capture in a 235U foil.

As a follow-on study to the feasibility of neutron capture therapy (NCT) with 235U brachytherapy seeds, physical doses were calculated and measured for the radiation from a 235U foil in a lucite phantom which was irradiated at the epithermal neutron irradiation port of the Brookhaven Medical Research Reactor. In addition, cell survival experiments were performed to obtain the relative biological effectiveness (RBE) for the neutron part of the radiation. The calculated absorbed doses agree with the measured ones. From cell survival experiments, it is deduced that the fission neutrons from the 235U foil have a RBE of 3.0 while the fast neutrons in the beam have a RBE of 3.8. Also observed is that, with the cells 7 mm from the foil, a significant amount of absorbed dose comes from the beta rays of 235U fission events. This absorbed dose from beta rays is a significant addition to the therapeutic dose. Due to the limited ranges of beta rays in tissue, this absorbed dose is restricted to the vicinity of the foil. This is the first demonstration of beta rays as part of NCT.

Beta Particles↗