PubMed Health⌕ Search

Biomedical subjects

H B Mark

Publications and source records attributed to H B Mark.

11 recordsLinked to original sources

Hydrogen peroxide sensitive amperometric biosensor based on horseradish peroxidase entrapped in a polypyrrole electrode.

The enzyme horseradish peroxidase (HRP) has been entrapped in situ by electropolymerization of pyrrole onto a platinum electrode. The latter was previously coated by a polypyrrole layer for better adhesion of the biocatalyst film and in order to avoid the enzyme folding onto the Pt electrode. The biosensor allowed the determination of hydrogen peroxide in the concentration range comprised between 4.9 x 10(-7) and 6.3 x 10(-4) M. The biosensor retained more than 90% of its original activity after 35 days of use.

Biosensing Techniques↗

Hydrogen sulfide determination by solid surface luminescence.

In the analytical system suggested, atmospheric hydrogen sulfide reacts with the surface of a filter paper treated with aqueous cadmium chloride and yields a luminescent species whose intensity can be correlated with the analyte concentration in ambient air. It was shown that the luminescent species are CdS solid particles which were formed in a well defined size. The paper luminescence was also tried on polymeric surfaces; polyethyleneoxide, polyvinyl alcohol, ethylcellulose and carboxymethylcellulose were found to give a similar luminescence signal. The system can be used on the tip of an optical fiber for an irreversible, cumulative type of analytical device for hydrogen sulfide determination. The 3s detection limit for the paper luminescence detection system was 7.8 ppb H(2)S.

Journal Article↗

Poly(binaphthyl-20-crown-6) as receptor based molecular selective potentiometric electrodes for catecholamines and other 1,2-dihydroxybenzene derivatives.

A novel type of poly(crown ether) electrode that is capable of selectively determining some 1,2-dihydroxybenzenes has been developed. A lipophilic macrocyclic crown ether, binaphthyl-20-crown-6, is electrochemically deposited on a platinum disc electrode. The film obtained is used as a sensory element for a potentiometric electrode for the determination of some neurotransmitters, namely, catecholamines. The new electrode is also capable of discriminating the steric shapes of 1,2-dihydroxybenzene moieties. The response of the new electrode is based on the principle of 'host-guest' chemistry. The potentiometric response is dependent on the pH of the solution and the nature of the buffer medium. The new sensor electrode has a useful analytical range of 1.5 x 10(-8) M-2 x 10(-5) M with a linear dynamic range between about 1 x 10(-7) M-5 x 10(-4) M with a 'super-Nernstian' slope of 110-130 mV/decade. The detection limit in phosphate buffer (0.1 M, pH 9.4) is ca. 3 x 10(-8) M for catecholamine. The sensor electrode is virtually insensitive towards interference from most inorganic ions and circumvents the interference from ascorbic acid, which is often found using amperometric methods in biological samples. A partial response mechanism of the present electrode is discussed, supported by results of electron dispersive analysis by x-rays (EDAX).

Animals↗

Electrochemistry and detection of some organic and biological molecules at conducting poly(3-methylthiophene) electrodes.

Electrodes modified by the electrodeposition of poly(3-methylthiophene) were used as chemical sensors for some organic and biological molecules of industrial and medicinal interest. The electrochemical behaviors of ferri/ferrocyanide, catechol, ascorbic acid, hydroquinone, dopamine epinephrine, acetaminophen, p-aminophenol and NADH were examined by cyclic voltammetry. The results showed that the proposed modified surface catalyzes the oxidation of these compounds. Differential pulse and square wave techniques were used for the analysis of binary mixture of ascorbic acid with catechol, NADH, dopamine and p-aminophenol. Voltammetric peak resolution was also demonstrated for a ternary mixture of ascorbic acid, catechol and p-aminophenol. Polymer coated electrode was also used in an amperometric detector for flow injection analysis of most of the aforementioned compounds. The responses of the polymer electrode were 4-10 times larger as compared to those of platinum. The modified electrode displayed excellent response stability for successive injections and detection limits were 10 ppb for catechol, dopamine, epinephrine, NADH and p-aminophenol, 1 ppb for acetaminophen and 100 ppb for ascorbic acid. Voltammetric peak positions were affected by the nature of the electrolyte and its pH. Also, film thicknesses were shown to be a factor affecting both the current magnitudes and oxidation peak potential of NADH.

Acetaminophen↗