PubMed Health⌕ Search

Biomedical subjects

H Benali

Publications and source records attributed to H Benali.

At least 19 recordsLinked to original sources

Federating distributed and heterogeneous information sources in neuroimaging: the NeuroBase Project.

The NeuroBase project aims at studying the requirements for federating, through the Internet, information sources in neuroimaging. These sources are distributed in different experimental sites, hospitals or research centers in cognitive neurosciences, and contain heterogeneous data and image processing programs. More precisely, this project consists in creating of a shared ontology, suitable for supporting various neuroimaging applications, and a computer architecture for accessing and sharing relevant distributed information. We briefly describe the semantic model and report in more details the architecture we chose, based on a media-tor/wrapper approach. To give a flavor of the future deployment of our architecture, we de-scribe a demonstrator that implements the comparison of distributed image processing tools applied to distributed neuroimaging data.

Databases as Topic↗

Evaluation of EEG localization methods using realistic simulations of interictal spikes.

Performing an accurate localization of sources of interictal spikes from EEG scalp measurements is of particular interest during the presurgical investigation of epilepsy. The purpose of this paper is to study the ability of six distributed source localization methods to recover extended sources of activated cortex. Due to the frequent lack of a gold standard to evaluate source localization methods, our evaluation was performed in a controlled environment using realistic simulations of EEG interictal spikes, involving several anatomical locations with several spatial extents. Simulated data were corrupted by physiological EEG noise. Simulations involving pairs of sources with the same amplitude were also studied. In addition to standard validation criteria (e.g., geodesic distance or mean square error), we proposed an original criterion dedicated to assess detection accuracy, based on receiver operating characteristic (ROC) analysis. Six source localization methods were evaluated: the minimum norm, the minimum norm weighted by multivariate source prelocalization (MSP), cortical LORETA with or without additional minimum norm regularization, and two derivations of the maximum entropy on the mean (MEM) approach. Results showed that LORETA-based and MEM-based methods were able to accurately recover sources of different spatial extents, with the exception of sources in temporo-mesial and fronto-mesial regions. Several spurious sources were generated by those methods, however, whereas methods using the MSP always located very accurately the maximum of activity but not its spatial extent. These findings suggest that one should always take into account the results from different localization methods when analyzing real interictal spikes.

Algorithms↗

Investigations of dipole localization accuracy in MEG using the bootstrap.

We describe the use of the nonparametric bootstrap to investigate the accuracy of current dipole localization from magnetoencephalography (MEG) studies of event-related neural activity. The bootstrap is well suited to the analysis of event-related MEG data since the experiments are repeated tens or even hundreds of times and averaged to achieve acceptable signal-to-noise ratios (SNRs). The set of repetitions or epochs can be viewed as a set of independent realizations of the brain's response to the experiment. Bootstrap resamples can be generated by sampling with replacement from these epochs and averaging. In this study, we applied the bootstrap resampling technique to MEG data from somatotopic experimental and simulated data. Four fingers of the right and left hand of a healthy subject were electrically stimulated, and about 400 trials per stimulation were recorded and averaged in order to measure the somatotopic mapping of the fingers in the S1 area of the brain. Based on single-trial recordings for each finger we performed 5000 bootstrap resamples. We reconstructed dipoles from these resampled averages using the Recursively Applied and Projected (RAP)-MUSIC source localization algorithm. We also performed a simulation for two dipolar sources with overlapping time courses embedded in realistic background brain activity generated using the prestimulus segments of the somatotopic data. To find correspondences between multiple sources in each bootstrap, sample dipoles with similar time series and forward fields were assumed to represent the same source. These dipoles were then clustered by a Gaussian Mixture Model (GMM) clustering algorithm using their combined normalized time series and topographies as feature vectors. The mean and standard deviation of the dipole position and the dipole time series in each cluster were computed to provide estimates of the accuracy of the reconstructed source locations and time series.

Brain Mapping↗

Multivariate source prelocalization (MSP): use of functionally informed basis functions for better conditioning the MEG inverse problem.

Spatially characterizing and quantifying the brain electromagnetic response using MEG/EEG data still remains a critical issue since it requires solving an ill-posed inverse problem that does not admit a unique solution. To overcome this lack of uniqueness, inverse methods have to introduce prior information about the solution. Most existing approaches are directly based upon extrinsic anatomical and functional priors and usually attempt at simultaneously localizing and quantifying brain activity. By contrast, this paper deals with a preprocessing tool which aims at better conditioning the source reconstruction process, by relying only upon intrinsic knowledge (a forward model and the MEG/EEG data itself) and focusing on the key issue of localization. Based on a discrete and realistic anatomical description of the cortex, we first define functionally Informed Basis Functions (fIBF) that are subject specific. We then propose a multivariate method which exploits these fIBF to calculate a probability-like coefficient of activation associated with each dipolar source of the model. This estimated distribution of activation coefficients may then be used as an intrinsic functional prior, either by taking these quantities into account in a subsequent inverse method, or by thresholding the set of probabilities in order to reduce the dimension of the solution space. These two ways of constraining the source reconstruction process may naturally be coupled. We successively describe the proposed Multivariate Source Prelocalization (MSP) approach and illustrate its performance on both simulated and real MEG data. Finally, the better conditioning induced by the MSP process in a classical regularization scheme is extensively and quantitatively evaluated.

Algorithms↗

Dynamics of parietofrontal networks underlying visuospatial short-term memory encoding.

Brain imaging studies in TEP, functional magnetic resonance imaging (fMRI) and electroencephalography (EEG) have shown that visuospatial short-term memory tasks depend on dorsal parietofrontal networks. Knowing the spatiotemporal dynamics of this network would provide further understanding of the neural bases of the encoding process. We combined magnetoencephalography (MEG) with EEG and fMRI techniques to study this network in a task, in which participants had to judge the symmetry in position of two dots, presented either simultaneously ("immediate comparison") or successively ("memorization" of a first dot and "delayed comparison", after 3 s, with a second dot). With EEG, larger amplitude was observed in the parietocentral P3b component (350-500 ms) in the immediate and "delayed comparisons" than in "memorization" condition, where topography at this time was more anterior and right lateralized. MEG provided a more accurate localization and temporal variations of sources, revealing a strong M4 component at 450 ms in the "memorization" condition, with two sources localized in parietal and right premotor regions. These localizations are consistent with both fMRI foci and EEG cortical current source densities (CSD), but only MEG revealed the strong increase in premotor region at 450 ms related to "memorization". These combined results suggest that EEG P3B and MEG M4 components reflect two different dynamics in parietofrontal networks: the parietocentral P3b indexes a decision mechanism during the immediate and "delayed comparisons", whereas the MEG M4 component, with a larger right premotor source, reflects the encoding process in visuospatial short-term memory.

Adult↗

A methodology for generating normal and pathological brain perfusion SPECT images for evaluation of MRI/SPECT fusion methods: application in epilepsy.

Quantitative evaluation of brain MRI/SPECT fusion methods for normal and in particular pathological datasets is difficult, due to the frequent lack of relevant ground truth. We propose a methodology to generate MRI and SPECT datasets dedicated to the evaluation of MRI/SPECT fusion methods and illustrate the method when dealing with ictal SPECT. The method consists in generating normal or pathological SPECT data perfectly aligned with a high-resolution 3D T1-weighted MRI using realistic Monte Carlo simulations that closely reproduce the response of a SPECT imaging system. Anatomical input data for the SPECT simulations are obtained from this 3D T1-weighted MRI, while functional input data result from an inter-individual analysis of anatomically standardized SPECT data. The method makes it possible to control the 'brain perfusion' function by proposing a theoretical model of brain perfusion from measurements performed on real SPECT images. Our method provides an absolute gold standard for assessing MRI/SPECT registration method accuracy since, by construction, the SPECT data are perfectly registered with the MRI data. The proposed methodology has been applied to create a theoretical model of normal brain perfusion and ictal brain perfusion characteristic of mesial temporal lobe epilepsy. To approach realistic and unbiased perfusion models, real SPECT data were corrected for uniform attenuation, scatter and partial volume effect. An anatomic standardization was used to account for anatomic variability between subjects. Realistic simulations of normal and ictal SPECT deduced from these perfusion models are presented. The comparison of real and simulated SPECT images showed relative differences in regional activity concentration of less than 20% in most anatomical structures, for both normal and ictal data, suggesting realistic models of perfusion distributions for evaluation purposes. Inter-hemispheric asymmetry coefficients measured on simulated data were found within the range of asymmetry coefficients measured on corresponding real data. The features of the proposed approach are compared with those of other methods previously described to obtain datasets appropriate for the assessment of fusion methods.

Adult↗

Detection of inter-hemispheric asymmetries of brain perfusion in SPECT.

Technetium-99m HMPAO and technetium-99m ECD single photon emission computed tomography (SPECT) imaging is commonly used to highlight brain regions with altered perfusion. It is particularly useful in the investigation of intractable partial epilepsy. However, SPECT suffers from poor spatial resolution that makes interpretation difficult. In this context, we propose an unsupervised voxel neighbourhood based method to assist the detection of significant functional inter-hemispheric asymmetries in brain SPECT, using anatomical information from MRI. For each MRI voxel, the anatomically homologous voxel in the contralateral hemisphere is identified. Both homologous voxel coordinates are then mapped into the SPECT volume using SPECT-MRI registration. Neighbourhoods are then defined around each SPECT voxel and compared to obtain a volume of inter-hemispheric differences. A volume including only the statistically significant inter-hemispheric differences is deduced from this volume using a non-parametric approach. The method was validated using realistic analytical simulated SPECT data including known asymmetries (in size and amplitude) as ground truth (gold standard). Detection performance was assessed using an ROC (receiver operating characteristic) approach based on the measures of the overlap between known and detected asymmetries. Validation with computer-simulated data demonstrates the ability to detect asymmetric zones with relatively small extension and amplitude. The registration of these detected functional asymmetries on the MRI enables good anatomical localization to be achieved.

Algorithms↗

Estimating the effective degrees of freedom in univariate multiple regression analysis.

The general linear model provides the most widely applied statistical framework for analyzing functional MRI (fMRI) data. With the increasing temporal resolution of recent scanning protocols, and more elaborate data preprocessing schemes, data independency is no longer a valid assumption. In this paper, we revise the statistical background of the general linear model in the presence of temporal autocorrelations. First, when detecting the activation signal, we explicitly account for the temporal autocorrelation structure, which yields a generalized F-test and the associated corrected (or effective) degrees of freedom (DOF). The proposed approach is data driven and thus independent of any specific preprocessing method. Then, for event-related protocols, we propose a new model for the temporal autocorrelations ("damped oscillator" model) and compare this model to another, previously used in the field (first-order autoregressive model, or AR(1) model). In the case of long fMRI time series, an efficient approximation for the number of effective DOF is provided for both models. Finally, the validity of our approach is assessed using simulated and real fMRI data and is compared with more conventional methods.

Analysis of Variance↗

Should scatter be corrected in both transmission and emission data for accurate quantitation in cardiac SPET?

Ideally, reliable quantitation in single-photon emission tomography (SPET) requires both emission and transmission data to be scatter free. Although scatter in emission data has been extensively studied, it is not well known how scatter in transmission data affects relative and absolute quantitation in reconstructed images. We studied SPET quantitative accuracy for different amounts of scatter in emission and transmission data using a Utah phantom and a cardiac Data Spectrum phantom including different attenuating media. Acquisitions over 180 degrees were considered and three projection sets were derived: 20% images and Jaszczak and triple-energy-window scatter-corrected projections. Transmission data were acquired using gadolinium-153 line sources in a 90-110 keV window using a narrow or wide scanning window. The transmission scans were performed either simultaneously with the emission acquisition or 24 h later. Transmission maps were reconstructed using filtered backprojection and mu values were linearly scaled from 100 to 140 keV. Attenuation-corrected images were reconstructed using a conjugate gradient minimal residual algorithm. The mu value underestimation varied between 4% with a narrow transmission window in soft tissue and 22% with a wide window in a material simulating bone. Scatter in the emission and transmission data had little effect on the uniformity of activity distribution in the left ventricle wall and in a uniformly hot compartment of the Utah phantom. Correcting the transmission data for scatter had no impact on contrast between a hot and a cold region or on signal-to-noise ratio (SNR) in regions with uniform activity distribution, while correcting the emission data for scatter improved contrast and reduced SNR. For absolute quantitation, the most accurate results (bias <4% in both phantoms) were obtained when reducing scatter in both emission and transmission data. In conclusion, trying to obtain the same amount of scatter in emission and transmission data, in addition to being impractical because of the difficulty in knowing the precise scatter components, did not yield such accurate absolute activity quantitation as when emission and transmission scatter were reduced.

Heart↗

Relative impact of scatter, collimator response, attenuation, and finite spatial resolution corrections in cardiac SPECT.

UNLABELLED: We determined the relative effect of corrections for scatter, depth-dependent collimator response, attenuation, and finite spatial resolution on various image characteristics in cardiac SPECT. METHODS: Monte Carlo simulations and real acquisition of a 99mTc cardiac phantom were performed under comparable conditions. Simulated and acquired data were reconstructed using several correction schemes that combined different methods for scatter correction (3 methods), depth-dependent collimator response correction (frequency-distance principle), attenuation correction (nonuniform Chang correction or within an iterative reconstruction algorithm), and finite spatial resolution correction (use of recovery coefficients). Five criteia were considered to assess the effect of the processing schemes: bull's-eye map (BEM) uniformity, contrast between the left ventricle (LV) wall and the LV cavity, spatial resolution, signal-to-noise ratio (SNR), and percent errors with respect to the known LV wall and liver activities. RESULTS: Similar results were obtained for the simulated and acquired data. Scatter correction significantly improved contrast and absolute quantitation but did not have noticeable effects on BEM uniformity or on spatial resolution and reduced the SNR. Correction for the depth-dependent collimator response improved spatial resolution from 13.3 to 9.5 mm in the LV region, improved absolute quantitation and contrast, but reduced the SNR. Correcting for attenuation was essential for restoring BEM uniformity (78% and 89% without and with attenuation correction, respectively [ideal value being 100%]) and accurate absolute activity quantitation (errors in estimated LV wall and liver activity decreased from 90% without attenuation correction to approximately20% with attenuation correction only). Although accurate absolute activity quantitation was achieved in the liver using scatter and attenuation corrections only, correction for finite spatial resolution was needed to estimate LV wall activity within 10%. CONCLUSION: The respective effects of corrections for scatter, depth-dependent collimator response, attenuation, and finite spatial resolution on different image features in cardiac SPECT were quantified for a specific acquisition configuration. These results give indications regarding the improvements to be expected when using a specific processing scheme involving some or all corrections.

Heart↗

Respective roles of scatter, attenuation, depth-dependent collimator response and finite spatial resolution in cardiac single-photon emission tomography quantitation: a Monte Carlo study.

The purpose of this study was to investigate the relative influence of scatter, attenuation, depth-dependent collimator response and finite spatial resolution upon the image characteristics in cardiac single-photon emission tomography (SPET). An acquisition of an anthropomorphic cardiac phantom was performed together with corresponding SPET Monte Carlo simulations. The cardiac phantom and the Monte Carlo simulations were designed so that the effect of scatter, attenuation, depth-dependent collimator response and finite spatial resolution could be studied individually and in combination. The impact of each physical effect and of combinations of effects was studied in terms of absolute and relative quantitative accuracy, spatial resolution and signal-to-noise ratio (SNR) in the resulting images. No corrections for these effects were assessed. Results obtained from Monte Carlo simulations and real acquisitions were in excellent agreement. Attenuation introduced about 90% activity underestimation in a 10-mm-thick left ventricle wall while finite spatial resolution alone introduced about 30% activity underestimation. Scatter had a negligible impact on quantitative accuracy in the recontructed slices when attenuation was present. Neither bull's eye map homogeneity nor contrast between a hot and a cold region were affected by depth-dependent collimator response or finite spatial resolution. Bull's eye map homogeneity was severely affected by attenuation but not by scatter. Attenuation and scatter reduced contrast by about 20% each. Both attenuation and scatter increased the full-width at half-maximum (FWHM) characterizing the spatial resolution of the imaging system by approximately 1 mm each but the main effect responsible for the observed 11-mm FWHM spatial resolution was the depth-dependent collimator response. SNR was reduced by a factor of approximately 2.5 because of attenuation, while scattered counts increased SNR by approximately 10%. In conclusion, the quantification of the relative influence of the different physical effects showed that attenuation is definitely the major phenomenon affecting cardiac SPET imaging accuracy, but that finite spatial resolution, scatter and depth-dependent collimator response also contribute significantly to the errors in absolute and relative quantitation and to the poor spatial resolution.

Computer Simulation↗

A spline-regularized minimal residual algorithm for iterative attenuation correction in SPECT.

In SPECT, regularization is necessary to avoid divergence of the iterative algorithms used for non uniform attenuation compensation. In this paper, we propose a spline-based regularization method for the minimal residual algorithm. First, the acquisition noise is filtered using a statistical model involving spline smoothing so that the filtered projections belong to a Sobolev space with specific continuity and derivability properties. Then, during the iterative reconstruction procedure, the continuity of the inverse Radon transform between Sobolev spaces is used to design a spline-regularized filtered backprojection method, by which the known regularity properties of the projections determine those of the corresponding reconstructed slices. This ensures that the activity distributions estimated at each iteration present regularity properties, which avoids computational noise amplification, thus stabilizing the iterative process. Analytical and Monte Carlo simulations are used to show that the proposed spline-regularized minimal residual algorithm converges to a satisfactory stable solution in terms of restored activity and homogeneity, using at most 25 iterations, whereas the non regularized version of the algorithm diverges. Choosing the number of iterations is therefore no longer a critical issue for this reconstruction procedure.

Algorithms↗

Experimental comparison of data transformation procedures for analysis of principal components.

Results of principal component analysis depend on data scaling. Recently, based on theoretical considerations, several data transformation procedures have been suggested in order to improve the performance of principal component analysis of image data with respect to the optimum separation of signal and noise. The aim of this study was to test some of those suggestions, and to compare several procedures for data transformation in analysis of principal components experimentally. The experiment was performed with simulated data and the performance of individual procedures was compared using the non-parametric Friedman's test. The optimum scaling found was that which unifies the variance of noise in the observed images. In data with a Poisson distribution, the optimum scaling was the norm used in correspondence analysis. Scaling mainly affected the definition of the signal space. Once the dimension of the signal space was known, the differences in error of data and signal reproduction were small. The choice of data transformation depends on the amount of available prior knowledge (level of noise in individual images, number of components, etc), on the type of noise distribution (Gaussian, uniform, Poisson, other), and on the purpose of analysis (data compression, filtration, feature extraction).

Computer Simulation↗

Two-dimensional statistical model for regularized backprojection in SPECT.

In SPECT, both the noise affecting the data and the discretization of the inverse Radon transform are responsible for the ill-posed nature of the reconstruction. To constrain the problem, we propose a regularized backprojection method (RBP) which takes advantage of the relationships existing between the continuity properties of the projections and those of the reconstructed object. The RBP method involves two stages: first, a statistical model (the fixed-effect model) is used to estimate the noise-free part of the projections. Then, the filtered projections are reconstructed using a backprojection algorithm (spline filtered backprojection) which ensures that the reconstructed object belongs to a space consistent with that containing the projections. The method is illustrated using analytical simulations, and the RBP approach is compared to the conventional filtered backprojection. The effect on the reconstructed slices of the parameters involved in RBP is studied in terms of spatial resolution, homogeneity in uniform regions and quantification. It is shown that appropriate combinations of these parameters yield a better compromise between homogeneity and spatial resolution than conventional FBP, with similar quantification performances.

Algorithms↗

Statistical distribution of factors and factor images in factor analysis of medical image sequences.

From a time or energy image sequence, factor analysis of medical image sequences (FAMIS) estimates factors, representing kinetics or spectra in a given physiological compartment, and associated factor images, showing the compartments corresponding to each curve. In this paper, we show that the statistical properties of factor images and associated factors can be determined using a well known result from elementary probability theory. Numerical experiments are conducted to demonstrate that the variance observed in factor images can be predicted when the statistical properties of the original data are known. It is shown how these theoretical results can be used to relax the non-negativity constraints during FAMIS oblique analysis and to improve the quantitative interpretation of the factor images by associating a confidence interval with each pixel value.

Biophysical Phenomena↗

Functional MR imaging of the human sensorimotor cortex during haptic discrimination.

This study attempted to determine whether haptic discriminations of shape (haptic task) activate the same tissue in the central cortical region of normal human subjects as do finger movements (opposition task). Opposition and haptic tasks both activated the central sulcus, as expected from previous imaging studies. The haptic task activated about 50% of the cortical territory activated by the opposition task. The results suggest that exploratory digital movements performed to collect precise somatosensory information and automatic movements performed during finger positioning activate partially overlapping parts of the sensorimotor cortex.

Brain Mapping↗

Polyhedral microcalcifications on mammograms: prevalence and morphometric analysis.

OBJECTIVE: The purpose of this study was to determine the incidence and the mammographic appearance of polyhedral microcalcifications. MATERIALS AND METHODS: Prospectively, we evaluated screening mammograms in 2000 women for polyhedral microcalcifications. The number of polyhedral microcalcifications on routine and magnification views was established, and a quantitative analysis was done to determine if the shape of the polyhedral microcalcifications varied in the different projections. The ratio between the longer axis (R) and the shorter axis (r) was calculated. RESULTS: Two radiologists detected at least two polyhedral microcalcifications on one projection in 58 (3%) women. The number of polyhedral microcalcifications detected ranged from 2 to 47 (mean, 8.2) for screening mammograms and from 2 to 62 (mean, 13.4) on magnification views. Polyhedral microcalcifications were bilateral in 22 cases, scattered in one breast in 19 cases, segmental in 10 cases, and grouped in a cluster in seven cases. Lateral projections showed more rhombohedral microcalcifications, and craniocaudal projections showed more square microcalcifications. CONCLUSION: The frequency of polyhedral microcalcifications is 3%. The shape of polyhedral microcalcifications varies: craniocaudal views show them to be square and lateral views show them to be rhombohedral.

Breast↗