PubMed Health⌕ Search

Biomedical subjects

H Bories

Publications and source records attributed to H Bories.

At least 19 recordsLinked to original sources

[Results of endoprostheses in the iliac arteries; an experience apropos of 47 implantations].

Obstruction or stenosis of the iliac artery was treated by placement of an endoprothesis in 41 patients. A total of 47 lesions was treated. 26 patients had poor results of balloon angioplasty including residual stenosis (7 cases), restenosis post angioplasty (7 cases), and dissection (12 cases). 15 patients had iliac occlusion. The endoprothesis used was a self expandable flexible endoprothesis (Wallstent) in 26 cases and a balloon expandable flexible endoprothesis (Strecker) in 21 cases. Complications included one thrombosis of the endoprothesis occurred immediately after placement, one hematoma. No distal embolization occurred. Patency at the end of the study was 70% at 9 months and 50% at 21 months. Patency was better with the Wallstent endoprothesis (60% at 21 months) than with the Strecker endoprothesis (38% at 21 months). Results was better with lesions of the common iliac artery, and when the indication was dissection or failure of angioplasty. During the 21 months of follow-up 18 occlusions or restenosis occurred. At the end of the study 20 patients (49%) were asymptomatic and improvement was achieved in 9 (22%), the clinical success rate was 71%. One amputation was required.

Aortic Dissection↗

Coronary artery perforation during coronary angioplasty.

In one patient percutaneous transluminal coronary angioplasty was complicated by coronary artery perforation of the left anterior descending coronary artery with light pericardial effusion. The outcome was favorable without either pericardiocentesis or emergency surgery.

Aged↗

[A possible application of percutaneous transluminal angioplasty: remodelling of an occluded aortocoronary bypass].

The authors report the case of a 53 year old patient who had undergone triple coronary bypass surgery for unstable angina. Recurrence of chest pain 4 months after surgery led to control coronary angiography which showed severe stenosis of the proximal and distal parts of the aorto-right coronary graft. Endoluminal dilatation was performed a few days later but, during angiography, complete occlusion of the graft was observed. This was repermeabilised without difficulty and a "remodelling" of the graft was carried out. The outcome was favourable with the complete regression of symptoms. The following alternatives to surgery are discussed: in cases of thrombosis which usually occur in the month following surgery, fibrinolysis may be attempted with a high success rate but a significant risk of haemo-pericardium: in cases of fibrous proliferation of the intima leading to stenosis or occlusion, endoluminal dilatation seems to be the procedure of choice, but this must always be carried out under surgical cover.

Angioplasty, Balloon↗

[A possible alternative in failure of percutaneous intracoronary fibrinolysis: percutaneous endoluminal dilatation].

The authors report three cases of myocardial infarction in which an attempt at intra-coronary fibrinolysis in the acute phase was either transiently effective or totally ineffective. In these three cases, percutaneous endoluminal dilatation was possible allowing restoration of correct coronary flow. The place of percutaneous angioplasty is therefore discussed either immediately after fibrinolysis, when the risk of re-thrombosis appears to be greatest or perhaps in the absence of an attempt at clot lysis, when fibrinolytic treatment is contra-indicated.

Angioplasty, Balloon↗

[Delirium tremens].

Explore the source record for details and available documents.

Alcohol Withdrawal Delirium↗