Membrane filtration for virus removal.

Incorporation of adequate clearance methodologies for viral safety assurance constitutes an integral part of the manufacturing process for plasma-derived biologicals. Filtration, being non-invasive, non-destructive and a < > mechanism for virus removal is often the method of choice. This paper discusses the virus filter performance characteristics and other process-related issues specifically applying to the Pall Ultipor VF filters (Grade DV50 and Grade DV20), which are operated in the direct flow filtration (DFF) mode and the Pall Filtron Omega VR filters (the Omega 300 K and Omega 100 K), which are operated in the tangential flow filtration (TFF) mode.

Animals↗

Process control procedures to augment quality control of leukocyte-reduced red cell blood products.

Quality control of leukocyte-reduced packed red cell units (LRprc) produced in blood facilities must conform to regulatory criteria, which state that units may not contain more than 1 x 10(6) to 5 x 10(6) white blood cells (WBC) per unit. The post-filtration WBC content of a total of n = 386 LRprc units was counted with a Nageotte chamber to model the probability that a unit would not meet the regulatory criteria. The distribution of the residual leukocyte counts is close to a negative binomial distribution (NBD) and is independent of the packed red cell volume filtered. The observed probability that a unit of blood has a residual WBC greater than 5 x 10(6) is 2.6 +/- 2.6 x 10(-3). A power analysis of the two-sample Kolmogorov-Smirnov (KS) test in this application shows that a sample size of 20 is sufficient for determining that the process is in control when an out of control process has a k NBD parameter greater than or equal to that of the in control process. The three out of control processes observed to date appear to have this property. A sample of size 80 may be necessary for confirming that process validation data sets conform to the larger 'reference' database (n = 386) for processes that are out of control in such a way that their k NBD parameter is less than the k parameter of the in control process.

Blood Component Removal↗

Lack of clinically significant contact system activation during platelet concentrate filtration by leukocyte removal filters.

When blood (plasma) contacts certain foreign surfaces, factor XII can activate and trigger a series of reactions leading to cleavage of kininogens with subsequent release of bradykinin. In this study, we investigated two different widely used leukocyte removal filters, Pall PXL8K (A) and Asahi PLS-5A (B), to test whether clinically significant contact activation occurred during leukodepletion of platelet-rich plasma (PRP). Kininogens were measured by particle concentration fluorescence immunoassay (PCFIA), which can detect cleavage of high and low molecular weight kininogens (HK and LK), the parent molecules of bradykinin, to determine if contact activation had occurred. A slight, nonsignificant decrease in HK and LK was observed with filter A after the first 5 mL was filtered that returned to prefiltration levels by the end of the filtration. Specific TotK (the combined measurement of HK and LK heavy chains divided by plasma protein concentration) showed a small, significant decrease with filter A after the first 5 mL of platelet concentrates was filtered that returned to prefiltration levels by the end of the filtration. There were no significant increases or decreases in the cleaved kininogen index (CKI), an index of HK proteolytic activation or HK and LK destruction (with release of bradykinin). These data suggest that small amounts of both HK and LK initially adsorb to filter A and then desorb, primarily intact. These data also indicate that no significant contact activation, as measured by PCFIA, occurs during leukodepletion of platelet concentrates with either filter A or B.

Blood Platelets↗

Removal of Mycobacterium species by breathing circuit filters.

Breathing circuit filters (BCFs) are used in respiratory and critical-care settings for humidification of air and to limit transmission of respiratory pathogens. Three types of BCFs (Pall BB 25A, BB 100, and HME 15-22) were evaluated (in triplicate) for removal of Mycobacterium species. Filters were challenged with aerosolized Mycobacterium bovis (a surrogate for Mycobacterium tuberculosis), at minimum total concentrations of 10(4) colony-forming units. No M bovis was recovered in the effluent, providing removal efficiencies of > 99.99% to > 99.999% for the filters tested.

Anesthesiology↗

Practical guidelines for process validation and process control of white cell-reduced blood components: report of the Biomedical Excellence for Safer Transfusion (BEST) Working Party of the International Society of Blood Transfusion (ISBT).

BACKGROUND: The increased use of white (WBC)-reduced blood components has prompted many institutions to develop quality assurance programs directed to such component preparation processes. For consistent preparation of WBC-reduced blood components that meet clinical needs as well as national standards, a program of process validation and control should be instituted. This involves controlling key factors that affect WBC reduction as well as periodic monitoring of the residual cellular content of components. Practical guidelines for the implementation of such a program are provided. STUDY DESIGN AND METHODS: A program involving three phases of monitoring was developed by individuals belonging to an international working party of the International Society of Blood Transfusion. RESULTS: The first phase, process validation, evaluates a minimum of 20 consecutive units (a minimum of 60 units when nonparametric measurements are used) to document the successful local implementation of a new or substantially modified process. Ongoing process control employing Levey-Jennings type control charts is used to demonstrate that the process remains stable over time. Process capability assessment and conformance with standards are evaluated once residual WBCs are counted in a sufficient number of units. This enables a facility to claim with a specified degree of confidence that a stated proportion of WBC-reduced units will meet national standards. Two approaches to determine the number of units that should be selected for counting are presented. The first approach considers units as either acceptable or not acceptable and assumes that the distribution of failed (or nonconforming) units approximates the Poisson distribution. The second approach takes into consideration the observed WBC content of the tested units, with the assumption that the residual WBC content in WBC-reduced components follows a lognormal distribution. A method to assess the lognormal distribution of residual WBCs is presented. Specific tables based on each of these approaches are provided to guide the reader in the design of a program that will verify conformance with any national standard at specific confidence levels. The approach can be generalized to other process control applications. CONCLUSION: Guidelines are presented for process validation, process control, and assessment of conformance in the production of WBC-reduced blood components. Policy makers retain the responsibility to establish, on the basis of the expected use of WBC-reduced components, requirements for the frequency of testing and for the proportion of prepared units that are expected with a stated degree of confidence to meet the standards. Facilities preparing WBC-reduced components can monitor key factors that influence the preparation of WBC-reduced blood, can periodically assess their conformance with the standards, and can intervene to correct adverse changes in the process. This approach can be used to ensure the consistent quality of WBC-reduced blood components.

Blood Component Removal↗

Multicenter evaluation of the 3% paraformaldehyde method for white cell counting in leukocyte-reduced red blood cells. BEST (Biomedical Excellence for Safer Transfusion) Working Party of the International Society of Blood Transfusion.

BACKGROUND/AIM: The 3% paraformaldehyde (PFA) method is a simple technique for counting residual white blood cells (WBC) in leukocyte-depleted red blood cells (RBC). Preliminary data suggested that its sensitivity is at least equal to PCR and flow cytometry. We report the results of a multicenter study conducted by the BEST Working Party to determine precision and accuracy of the 3% PFA method. STUDY DESIGN: In the 7 participating laboratories, 5 sets of samples containing nominal concentrations of 200, 100, 50, and 10 WBC/ml were prepared by diluting whole blood into 'WBC-free' RBC. Ten milliliters of each sample were processed using the 3% PFA method, which is based on erythrocyte lysis and WBC concentration into 5% of the original sample volume; a Nageotte chamber is used to count concentrated WBC. RESULTS: The precision of the technique varied according to the nominal concentration, ranging from a CV of 12% at 200 WBC/ml to 57% at 10 WBC/ml. The technique measured fewer than the nominal WBC concentrations (mean of all laboratories, -12.4%); underestimation was probably due to cell loss during sample manipulation. Overall accuracy was however acceptable, because statistical considerations establish that the actual WBC concentration would unlikely exceed 2 times the estimated count. CONCLUSIONS: The 3% PFA method is suitable for the enumeration of residual WBC at concentrations > or = 50/ml. It represents a useful tool for evaluation of high performance filters by reference laboratories.

Cell Separation↗

Chemiluminescent detection of DNA on nylon membranes.

Two types of nonradioactive DNA detection systems were optimized for use with nylon membranes in Southern transfers. A luminol substrate system (consisting of an enhanced chemiluminescent reaction utilizing luminol enzyme substrate) was used with peroxidase-labeled probe DNA, and a dioxetane-based substrate was used with alkaline phosphatase/antibody and digoxigenin-labeled probe DNA. Chemiluminescence was detected by autoradiography. Methods for reprobing the membranes were also optimized for both systems; blots could be reprobed at least ten times. Results showed that excellent sensitivity and low background can be achieved on both amphoteric and positively charged nylon membranes, using either detection system.

Alkaline Phosphatase↗

Blinded, two-laboratory comparative analysis of Escherichia coli heat-stable enterotoxin production by using monoclonal antibody enzyme-linked immunosorbent assay, radioimmunoassay, suckling mouse assay, and gene probes.

Heat-stable enterotoxin (ST)-producing enterotoxigenic Escherichia coli (ETEC) can be identified by a variety of assays, including the suckling mouse assay (SMA), radioimmunoassay (RIA), polyclonal or monoclonal antibody enzyme-linked immunosorbent assay (ELISA), and DNA hybridization with STh and STp gene probes. To compare the sensitivity and reliability of these assays, 100 coded ETEC and non-ETEC isolates were blindly tested in two independent laboratories. SMA, RIA, and monoclonal ELISA were performed in Cincinnati, Ohio, while gene probe analysis was performed in Baltimore, Md. The method of storage of organisms had a profound effect on the stability of plasmids in certain strains. Hybridization experiments to determine the presence or absence of the enterotoxin gene showed that strains stored on Dorset egg medium at room temperature better retained their plasmids than strains stored frozen in skim milk. Forty-four of the 100 organisms obtained from the skim milk stock were found to produce STa in liquid culture by the RIA, SMA, and monoclonal ELISA (100% agreement). However, 50 of 54 of the strains stored on Dorset egg medium which were originally classified as STa+ or ST+ LT+ (positive for both heat-stable and heat-labile [LT] enterotoxins) were found to produce STa and retain the plasmid by each of these assays. Three additional strains were found which harbored the plasmid but did not elaborate STa by any of the assays (3% discrepancy). The monoclonal antibody ELISA appears to be highly reliable for determination of STa production by ETEC and can be easily scored visually even by untrained personnel. Furthermore, when this STa assay is coupled with a polyclonal antibody assay, it is possible to predict the genotype of STh- and STp-producing organisms.

Animals↗

Production of neutralizing monoclonal antibodies to Escherichia coli heat-stable enterotoxin.

In an effort to develop new approaches to the study and control of infectious diarrhea, we prepared murine monoclonal antibodies to the Escherichia coli heat-stable enterotoxin (STa). The toxin was purified from E. coli culture media and conjugated to bovine serum albumin. The STa-bovine serum albumin conjugate was used to immunize BALB/c mice, and the immune spleen cells from these mice were fused with SP2/0 myeloma cells. Resultant hybridomas were screened in an enzyme-linked immunosorbent assay protocol against 500 ng of STa-bovine serum albumin bound to microtiter wells as the solid-phase antigen. Five stable clones were selected and grown further in ascites fluid, which demonstrated anti-STa activity at dilutions of up to 1:500,000 in the enzyme-linked immunosorbent assay for heat-stable enterotoxin. In a competitive enzyme-linked immunosorbent assay format, the antibodies recognized several human and porcine strains of STa to various extents, but did not recognize E. coli heat-labile toxin, cholera toxin, or staphylococcal enterotoxin B. The antibodies were all able to bind lactoperoxidase-labeled [125I]STa, and antibody 20B3 was also able to dissociate [125I]STa bound to toxin receptors on rat jejunal villous cells. Preincubation of STa with antibodies 20B3 or 20F5 led to a concentration-dependent neutralization of toxin activity in a suckling mouse intestinal secretion assay. These antibodies are likely to provide new tools for the continued study of STa structure-function relationships and may lead to improved diagnosis and treatment of E. coli-induced infectious diarrhea.

Animals↗

Simple and reliable enzyme-linked immunosorbent assay with monoclonal antibodies for detection of Escherichia coli heat-stable enterotoxins.

We have developed a sensitive and specific competitive enzyme-linked immunosorbent assay for Escherichia coli heat-stable enterotoxins consisting of methanol-soluble, suckling mouse active peptides with similar core sequences (STa) by using monoclonal antibodies prepared against STa purified from a human isolate. The assay can detect 3 to 20 pg of purified STa, depending on the monoclonal antibody used in the assay. The assay is rapid, requiring ca. 1 h to complete. With this competitive enzyme-linked immunosorbent assay, we measured STa production by enterotoxigenic E. coli directly in Casamino Acid-yeast extract culture supernatants. The assay was suitable for measuring STa in culture supernatants from human, bovine, and porcine E. coli isolates. No cross-reactivity was observed with heat-labile enterotoxin, cholera toxin, or heat-stable enterotoxin STb, which is a methanol-insoluble peptide(s) active in the ligated pig jejunal loop test. A 100% correlation of toxin production was found by comparing the enzyme-linked immunosorbent assay with the previously established radioimmunoassay for STa and with suckling mouse activity.

Animals↗

Production and characterization of monoclonal antibodies to soluble rat lung guanylate cyclase.

Four monoclonal antibodies to rat lung soluble guanylate cyclase [GTP pyrophosphate-lyase (cyclizing) EC 4.6.1.2] have been produced by fusing spleen cells from immunized BALB/c mice with SP-2/0 myeloma cells. The antibodies were detected by their ability to bind immobilized guanylate cyclase and by immunoprecipitation of purified enzyme in the presence of second (rabbit anti-mouse) antibody. After subcloning by limiting dilution, hybridomas were injected intraperitoneally into mice to produce ascitic fluid containing 2-5 mg of antibody per ml. The four antibodies obtained had titers of between 1:1580 and 1:3160 but were detectable at dilutions greater than 1:20,000. Soluble guanylate cyclase from several rat tissues were crossreactive with the four monoclonal antibodies, suggesting that the soluble enzyme from different rat tissues is antigenically similar. The antibodies also recognized soluble lung enzyme from rat, beef, and pig, while enzyme from rabbit was not crossreactive and mouse enzyme was recognized by only one of the antibodies. Particulate guanylate cyclase from a number of tissues had only minimal crossreactivity with the antibodies. Immunoprecipitated guanylate cyclase retained catalytic activity, could be activated with sodium nitroprusside, and was inhibited by cystamine. None of the antibodies were inhibitory under the conditions examined. These antibodies will be useful probes for the study of guanylate cyclase regulation and function under a variety of physiological conditions.

Animals↗

Application of bacteriophages as surrogates for mammalian viruses: a case for use in filter validation based on precedents and current practices in medical and environmental virology.

Infectivity-based assays are the assays of choice for the detection of pathogenic mammalian viruses. While it is intuitively appropriate to conduct testing and validation studies with the known viral burden or a closely related mammalian species, logistic considerations often dictate otherwise. Consequently, bacteriophages have served as suitable surrogates for mammalian viruses in both medical and environmental virology applications. The wide range of bacteriophages available offers a powerful analytical tool amenable to several different applications: filter validation studies (where removal is based on size exclusion), investigations into virus contamination control issues, evaluation of barrier materials, etc. There is a considerable body of evidence to suggest and support the use of bacteriophages as surrogates for mammalian viruses. Use of appropriately sized bacteriophages provides an innocuous, efficacious and expeditious method for economical testing and validation of viral clearance capabilities of virus removal filters, thus facilitating performance of filter validation studies in biopharmaceuticals under product- and process-specific conditions in an overall effort towards ensuring the virological safety of biologicals. This paper discusses the limitations associated with mammalian virus assays and provides a rationale for the use of bacteriophages as surrogates for mammalian viruses. Data from published literature documenting applicability of bacteriophages in filter validation studies, especially when removal is based on size exclusion, is reviewed along with examples of studies from the fields of medical and environmental virology.

Bacteriophages↗

Application of membrane filtration for removal of diminutive bioburden organisms in pharmaceutical products and processes.

In this report, we present results of a recent investigation in our laboratories demonstrated the effect of process conditions and/or drug product composition on the ability of 0.2 micron and 0.22 micron sterilizing grade filters to fully retain Ralstonia (formerly Burkholderia, formerly Pseudomonas) pickettii. R. pickettii is a opportunistic pathogen widely distributed in nature as well as clinical specimens and there have been several reports of nosocomial infections due to intrinsic manufacture-related R. pickettii contamination in filter-sterilized parenteral fluids. This study documents the penetration of 0.2 micron nylon 66 and 0.22 micron modified PVDF sterilizing grade filters by R. pickettii (grown and challenged) in a drug solution under conditions that simulated a pharmaceutical filling operation. Penetration was not observed for every filter disc tested, and this may be explained, in part, by the stochastic nature (i.e., governed by the rules of probability) of the retention mechanisms involved. Scanning electron microscopy revealed significant changes in the microorganism's size and morphology as a result of exposure to the drug solution; these changes are consistent with those reported for bacteria subjected to nutrient deprivation. The SEM analyses of R. pickettii challenge suspensions in the drug solution showed that the average cell length decreased from 1.25 +/- 0.27 microns to 0.84 +/- 0.17 micron between zero and 24 hours. In addition, significant changes were observed in the size (length) distributions, with approximately 35% of the cells at 24 hours being smaller than any cell observed at the start of the challenge. These data suggest that the significant reduction in bioburden size and morphology that occurred as a result of exposure to the drug solution may play a role in the reduced ability of the 0.2 micron and 0.22 micron filters tested in this study to retain these organisms. Under the same test conditions where penetration of 0.2/0.22 micron filters was observed, 0.1 micron rated membrane filters qualified with both B. diminuta and Acholeplasma laidlawii mycoplasma consistently provided sterile effluent. Bacterial penetration of 0.2 (or 0.22) micron sterilizing grade filters was not observed under identical test conditions with either R. pickettii in a standardized solution (saline lactose broth) routinely used in challenge testing filters, or with the standard test organism, B. diminuta, in the drug solution. This study thus supports the renewed emphasis on both product- and process specific validation as well as routine bioburden monitoring expressed by regulatory agencies, and the use of enhanced bacterial removal efficiency 0.1 micron rated filters to provide enhanced sterility assurance in pharmaceutical processes.

Bacteria↗

Retention of water-borne bacteria by membrane filters. Part III: Bacterial challenge tests on 0.1 micron rated filters.

Clear performance differences were observed between different 0.1 micron rated filters in terms of their microbial removal efficiency when challenged with naturally occurring waterborne bacteria from a water source. Penetration occurred with three 0.1 micron rated "sterilizing grade" filter types tested, from three different filter manufacturers, that did not have a specific high titer reduction claim for Acholeplasma laidlawii. Bacteria shown to penetrate these 0.1 micron rated filters were quite similar to those recovered downstream of 0.2.0.22 micron rated filters (described in Part II). All of the isolates identified via FAME analyses were common environmental or ubiquitous organisms, and some, such as Acidovorax sp. and Hydrogenophaga pseudoflava, have also been isolated from pharmaceutical water systems. In contrast, four different 0.1 micron rated "sterilizing grade" filter types from two different manufacturers, which had been qualified with both B. diminuta and A. laidlawii, consistently produced sterile effluents under similar test conditions. This study thus highlights the need for an industry or regulatory standard method of defining the microbial removal performance of 0.1 micron rated filters, and supports the use of functionally qualified 0.1 micron rated filters as sterilizing grade filters in pharmaceutical operations for enhanced sterility assurance.

Bacteria↗

Retention of water-borne bacteria by membrane filters. Part I: Bacterial challenge tests on 0.2 and 0.22 micron rated filters.

The results of bacterial challenge tests conducted on several 0.2 and 0.22 micron rated "sterilizing grade" filter cartridge types with bacteria from a natural water source are presented. Eight different 0.2/0.22 micron rated "sterilizing grade" filter types from four different filter manufacturers, claimed to be capable of retaining Brevundimonas diminuta at a challenge level of 10(7) CFU/cm2, were tested. The filters tested included nylon 6.6 and polyamide filters from two manufacturers, modified or hydrophilic PVDF filters from two manufacturers, modified or asymmetric PES filters from three manufacturers, and cellulose acetate filters from a single manufacturer. Consistent bacterial penetration was observed, over the 18-24 h challenge period, for all twenty-five integral 0.2 and 0.22 micron rated filter cartridges tested, at challenge levels of about 10(1)-10(4) CFU/cm2, indicating that natural waterborne bacteria were more penetrative than B. diminuta. The observed penetration was thus qualitatively independent of filter media type or manufacturer. These results add to the growing body of evidence that shows 0.2 and 0.22 micron rated filters may not remove all microorganisms under all conditions. These results further establish that bacterial penetration of 0.2/0.22 micron rated filters is not limited just to (1) specific membrane types, or (2) extended duration challenges (>> 24 h), or (3) extremely high challenge levels, or (4) bacteria that can only exist in a penetrative state in an artificial laboratory setting.

Culture Media↗