PubMed Health⌕ Search

Biomedical subjects

H Brian Halsall

Publications and source records attributed to H Brian Halsall.

11 recordsLinked to original sources

Bacillus globigii bugbeads: a model simulant of a bacterial spore.

Nonpathogenic microorganisms are often used as simulants of biological pathogens during the initial phase of detection method development. While these simulants approximate the size, shape, and cellular organization of the microorganism of interest, they do not resemble its surface protein content, a factor particularly important in methods based on immunorecognition. Here, we develop and detect an artificial bacterial spore--B. globigii (BG) Bugbead-a particle mimicking the antigenic surface of BG spores. Two methods of spore protein extraction were compared both quantitatively (by protein concentration assay) and qualitatively (by SDS-PAGE and Western blot): extraction by mechanical disruption and extraction by chemical decoating. The former method was more efficient in producing more protein and a greater number of antigens. BG Bugbeads were made by conjugating the extracted proteins to 0.8-microm carboxyl-coated polystyrene particles via carbodiimide coupling. BG Bugbeads were successfully detected by a bead-based enzyme-labeled immunoassay with fluorescence detection with a detection limit of 6.9 x 10(3) particles/mL. Formation of the Bugbead-capture bead complex was confirmed by ESEM. The concept of a harmless artificial spore can be applied to developing improved simulants for pathogenic spore-forming microorganisms such as B. anthracis, C. botulinum, and B. cereus, which can to be used for method validation, instrument calibration, and troubleshooting.

Antigens, Bacterial↗

Fabrication of comb interdigitated electrodes array (IDA) for a microbead-based electrochemical assay system.

This research is directed towards developing a more sensitive and rapid electrochemical sensor for enzyme labeled immunoassays by coupling redox cycling at interdigitated electrode arrays (IDA) with the enzyme label beta-galactosidase. Coplanar and comb IDA electrodes with a 2.4 microm gap were fabricated and their redox cycling currents were measured. ANSYS was used to model steady state currents for electrodes with different geometries. Comb IDA electrodes enhanced the signal about three times more than the coplanar IDAs, which agreed with the results of the simulation. Magnetic microbead-based enzyme assay, as a typical example of biochemical detection, was done using the comb and coplanar IDAs. The enzymes could be placed close to the sensing electrodes (approximately 10 microm for the comb IDAs) and detection took less than 1 min with a limit of detection of 70 amol of beta-galactosidase. We conclude that faster and more sensitive assays can be achieved with the comb IDA.

Biosensing Techniques↗

Binding of alpha1-acid glycoprotein to membrane results in a unique structural change and ligand release.

Alpha(1)-acid glycoprotein (AGP) consists of 183 amino acid residues and 5 carbohydrate chains and binds to basic and neutral drugs as well as steroid hormones. We investigated the structural properties and ligand-binding capacity of AGP under mild acidic conditions and its interactions with liposomes prepared from neutral or anionic lipids and the neutral drug, progesterone. Interestingly, AGP had a unique structure at pH 4.5, at which the tertiary structure changed, whereas the secondary structure remained intact. Furthermore, the binding capacity of AGP for progesterone did not significantly change under these conditions. It was also observed that AGP was strongly bound to the anionic membrane at pH 4.5, forming an alpha-helix-rich structure from the original beta-sheet-rich structure, which significantly decreased the binding capacity of AGP for progesterone. The structural transitions as well as the membrane binding were suppressed by adding NaCl. These results indicate that AGP has a unique structure on the membrane surface under mild acidic conditions. The conformational change induces binding to the membrane aided by electrostatic interaction, and AGP subsequently takes on a predominantly alpha-helical conformation.

Acids↗

Microbead-based electrochemical immunoassay with interdigitated array electrodes.

The objective of this study was to develop a sensitive and miniaturized immunoassay by coupling a microbead-based immunoassay with an interdigitated array (IDA) electrode. An IDA electrode amplifies the signal by recycling an electrochemically redox-reversible molecule. The microfabricated platinum electrodes had 25 pairs of electrodes with 1.6-microm gaps and 2.4-microm widths. An enzyme-labeled sandwich immunoassay on paramagnetic microbeads with mouse IgG as the analyte and beta-galactosidase as the enzyme label was used as the model system. beta-Galactosidase converted p-aminophenyl beta-D-galactopyranoside to p-aminophenol (PAP). This enzyme reaction was measured continuously by positioning the microbeads near the electrode surface with a magnet. Electrochemical recycling occurred with PAP oxidation to p-quinone imine (PQI) at +290 mV followed by PQI reduction to PAP at -300 mV vs Ag/AgCl. Dual-electrode detection amplified the signal fourfold compared to single-electrode detection, and the recycling efficiency reached 87%. A calibration curve of PAP concentration vs anodic current was linear between 10(-4) and 10(-6)M. A signal from 1000 beads in a 20-microL drop was detectable and the immunoassay was complete within 10 min with a detection limit of 3.5x10(-15)mol mouse IgG.

Aminophenols↗

Bead-based electrochemical immunoassay for bacteriophage MS2.

Viruses are one of four classes of biothreat agents, and bacteriophage MS2 has been used as a simulant for biothreat viruses, such as smallpox. A paramagnetic bead-based electrochemical immunoassay has been developed for detecting bacteriophage MS2. The immunoassay sandwich was made by attaching a biotinylated rabbit anti-MS2 IgG to a streptavidin-coated bead, capturing the virus, and then attaching a rabbit anti-MS2 IgG-beta-galactosidase conjugate to another site on the virus. beta-Galactosidase converts p-aminophenyl galactopyranoside (PAPG) to p-aminophenol (PAP). PAPG is electroinactive at the potential at which PAP is oxidized to p-quinone imine (PQI), so the current resulting from the oxidation of PAP to PQI is directly proportional to the concentration of antigen in the sample. The immunoassay was detected with rotating disk electrode (RDE) amperometry and an interdigitated array (IDA) electrode. With an applied potential of +290 mV vs Ag/AgCl and a rotation rate of 3000 rpm, the detection limit was 200 ng/mL MS2 or 3.2 x 10(10) viral particles/mL with RDE amperometry. A trench IDA electrode was incorporated into a poly(dimethyl siloxane) channel, within which beads were collected, incubated with PAPG, and PAP generation was detected. The two working electrodes were held at +290 and -300 mV vs Ag/AgCl, and electrochemical recycling of the PAP/PQI couple by the IDA electrode lowered the limit of detection to 90 ng/mL MS2, or 1.5 x 10(10) MS2 particles/mL.

Aminophenols↗

Bead-based immunoassays with microelectrode detection.

The suitability of a microelectrode as the detector for a small-volume, bead-based enzyme-labeled immunoassay for later use in a microfluidic device was investigated. The microelectrode helps to overcome consumption of the electroactive species by the electrode (depletion) that is encountered with macroelectrodes such as the rotating disk electrode (RDE) and allows the volume of the detection cell to be reduced. Microelectrodes also allow the chemical reactions to be monitored in real time due to the electrodes' close proximity to the assay site. A bead-based sandwich immunoassay for mouse IgG was developed with alkaline phosphatase (AP) as the enzyme label, p-aminophenyl phosphate (PAPP) as the enzyme substrate, and microelectrode detection. The diffusion coefficient of the product of enzymatic hydrolysis, p-aminophenol (PAP), was determined to be 7.2+/-0.9 x 10(-6) cm(2) s(-1). The detection limits were determined for free (0.52 ng mL(-1)) and bead-bound AP (10 ng mL(-1)). The number of binding sites for AP per bead was calculated to be 9.6 x 10(4) molecules/bead, and under saturation conditions the minimum detectable number of beads was 2500. Lower detection limits could be achieved with the microelectrode than the RDE while maintaining similar reproducibility. The microelectrode also made it possible to work with lower sample volumes (down to 10 microL) than with the RDE (minimum volume of 40 microL). Depletion of PAP was not observed with the microelectrode. The results obtained here with a microelectrode showed great promise for later use of microelectrodes in microfluidic devices with limited sample volumes. RDE detection cannot be used in a microfluidic system due to its complex set-up that includes a motor for rotation.

Alkaline Phosphatase↗

Detection of secretion from pancreatic islets using chemically modified electrodes.

Secretion of insulin from pancreatic islets was monitored indirectly by detecting zinc. Anodic stripping voltammetric measurements of zinc were done on a bismuth-modified electrode. Comparison of the performance of bismuth-modified electrodes and mercury film electrodes showed that bismuth is an appropriate alternative for Zn detection. The bismuth-coated electrode was used to detect zinc in insulin samples and insulin secreted from pancreatic islets upon stimulation with high concentrations of K(+). Detection of zinc released from pancreatic islets was done in the culture medium without any further cleanup. This detection method can be used to monitor secretion from pancreatic islets in their native environment.

Animals↗

Determination of endogenous extracellular signal-regulated protein kinase by microchip capillary electrophoresis.

The application of microchip capillary electrophoresis (CE) to the assay of extracellular signal-regulated protein kinase (ERK) is presented. In this assay, ERK catalyzes the transfer of gamma-phosphate from adenosine 5(')-triphosphate to the threonine residue of a fluorescently labeled nonapeptide (APRTPGGRR), and the phosphorylated and nonphosphorylated peptides were detected by fluorescence. The phosphorylated and nonphosphorylated peptides and the internal standard were separated within 20s, and the increase in magnitude of the phosphorylated peptide peak was monitored to assess ERK activity. ERK reactions were prepared off-chip and analyzed on a single-lane glass microchip fabricated by standard methods. It was demonstrated that microchip CE could be used to measure endogenous amounts of ERK by spiking known concentrations of recombinant ERK2 into the lysates of serum-starved human umbilical vein endothelial cells (HUVEC) and recovering between 90 and 100% for all samples. Endogenous ERK activity was determined by microchip where HUVEC were stimulated with 500pM vascular endothelial growth factor (VEGF) at different times before cell lysis. The results showed a transient VEGF-mediated ERK activation that peaked at 10min, which was consistent with previous reports using conventional techniques. The microchip assay provided a rapid, accurate, and precise alternative to conventional methods of determining endogenous ERK activity.

Cells, Cultured↗

Development and characterization of simulant pancreatic islets.

Insulin is stored in pancreatic islets as a zinc-insulin complex, and stimulating the islets results in the release of insulin and zinc. Simulant pancreatic islet beads have been developed using agarose beads (50-250 micro m diameter) derivatized with iminodiacetic acid that have been loaded with zinc. A qualitative comparison of the simulant beads with pancreatic islets has been made by staining with dithizone and a zinc-binding fluorescent dye, TSQ. The binding capacity of simulant beads was determined to be 34 micro mol Zn(2+)/g of dried beads using anodic stripping voltammetry. Hydrochloric acid was used to release zinc from beads to mimic the secretion of insulin from pancreatic islets and a release profile was established. The simulant beads can be used to optimize the islet isolation process and reduce the use of real islets in method development.

Animals↗

Structural and drug-binding properties of alpha(1)-acid glycoprotein in reverse micelles.

Alpha(1)-acid glycoprotein (AGP) is a glycoprotein that consists of 183 amino acid residues and five carbohydrate chains and binds to neutral and basic drugs. We examined the structural properties and ligand-binding capacity of AGP in interactions with reverse micelles. Also, detailed information was obtained by comparing several different states of AGP. Interaction with reverse micelles induced a unique conformational transition (beta-sheet to alpha-helices) in AGP and decreased the binding capacity for the basic drug, chlorpromazine and the steroid hormone, progesterone to AGP. These structural conformations are very similar to those observed under conditions of acidity and high ionic strength (pH 2.0, 1.5 M NaCl). This structure seems to be an intermediate between the native state and the denatured state, possibly a molten globule. The present results suggest that when AGP interacts with the biomembrane, it undergoes a structural transition to a unique structure that differs from the native and denatured states and has a reduced ligand-binding capacity.

Chlorpromazine↗

An integrated microfluidic biochemical detection system for protein analysis with magnetic bead-based sampling capabilities.

This paper presents the development and characterization of an integrated microfluidic biochemical detection system for fast and low-volume immunoassays using magnetic beads, which are used as both immobilization surfaces and bio-molecule carriers. Microfluidic components have been developed and integrated to construct a microfluidic biochemical detection system. Magnetic bead-based immunoassay, as a typical example of biochemical detection and analysis, has been successfully performed on the integrated microfluidic biochemical analysis system that includes a surface-mounted biofilter and electrochemical sensor on a glass microfluidic motherboard. Total time required for an immunoassay was less than 20 min including sample incubation time, and sample volume wasted was less than 50 microl during five repeated assays. Fast and low-volume biochemical analysis has been successfully achieved with the developed biofilter and immunosensor, which is integrated to the microfluidic system. Such a magnetic bead-based biochemical detection system, described in this paper, can be applied to protein analysis systems.

Electrochemistry↗