Hydroxyapatite coating converts fibrous tissue to bone around loaded implants.

In previous studies, we have demonstrated a fibrocartilaginous membrane around hydroxyapatite-coated implants subjected to micromovement in contrast to the fibrous connective tissue which predominates around similarly loaded titanium alloy implants. In the present study, in mature dogs, we investigated the effect of immobilising titanium (Ti)- or hydroxyapatite (HA)-coated implants already surrounded by a movement-induced fibrous membrane and compared the results with those of similar implants in which continuous micromovement was allowed to continue. The implants were inserted in the medial femoral condyles of 14 dogs and subjected to 150 microns movements during each gait cycle. After four weeks (when a fibrous membrane had developed), half the implants were immobilised to prevent further micromovement. The dogs were killed at 16 weeks and the results were evaluated by push-out tests and histological analysis. The continuously loaded Ti-coated implants were surrounded by a fibrous membrane, whereas bridges of new bone anchored the HA-coated implants. The immobilised implants were surrounded by bone irrespective of the type of coating. Push-out tests of the continuously loaded implants showed better fixation of those with HA coating (p < 0.001). The immobilised Ti-coated implants had four times stronger fixation than did continuously loaded Ti-coated implants (p < 0.01) but there was no equivalent difference between the two groups of HA-coated implants. The amount of bone ingrowth was greater into immobilised HA-coated implants than into immobilised Ti-coated implants (p < 0.01). Two-thirds of the HA coating had been resorbed after 16 weeks of implantation, but 25% of this resorbed HA had been replaced by bone.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Hydroxyapatite coating modifies implant membrane formation. Controlled micromotion studied in dogs.

We studied the influence of controlled micromovements between bone and porous titanium alloy implants with and without hydroxyapatite coating. A dynamically loaded unstable device producing approximately 150-microns axial translation of knee implants during each gait cycle was developed. Stable implants served as controls. Matched stable and unstable implants with either porous titanium (Ti) or hydroxyapatite (HA) coating surrounded by a gap of 0.75 mm were inserted into the weight-bearing regions of the medial femoral condyles in 14 mature dogs. Histologic analysis after 4 weeks showed a fibrous membrane surrounding both types of implants subjected to micromovements, whereas various amounts of bone ingrowth was obtained in the stable implants. The membrane around unstable HA implants was thinner than that around unstable Ti implants. Islands of fibrocartilaginous tissue characterized the membrane around unstable HA implants, whereas fibrous connective tissue surrounded unstable Ti implants. The collagen concentration of the fibrous membranes was higher around unstable HA implants compared with Ti implants. Instability reduced the shear strength of the implants. However, the shear strength of unstable HA implants exceeded that of the Ti implants, both unstable and stable. The greatest shear strength was obtained by stable HA implants, i.e., tenfold greater than that of stable Ti implants. The gap-healing capacity around stable HA implants increased toward the HA surface, and was greater than that around Ti implants. Our study demonstrates that micromovements between bone and implant inhibit bone ingrowth and lead to the development of a fibrous membrane. The superior fixation of unstable HA implants compared with unstable Ti implants may be ascribed to the presence of fibrocartilage, a higher collagen concentration, and radiating orientation of collagen fibers in the membrane. The strongest mechanical anchorage and the greatest amount of bone ingrowth was obtained by stable implants coated with hydroxyapatite.

Alloys↗

Bone graft incorporation around titanium-alloy- and hydroxyapatite-coated implants in dogs.

To evaluate cancellous allogenic bone graft incorporation into porous-coated implants, the fixation of titanium alloy-(Ti) and hydroxyapatite-(HA) coated implants with and without bone graft was compared. An unloaded model with unilateral carragheenin-induced osteopenia of the knee was used in 12 mature dogs. Ti- and HA-coated cylinders were implanted in the distal femoral condyles and centralized in 2-mm overreamed drill holes. Allogenic, fresh-frozen (-80 degrees) cancellous bone graft was packed around the implants in six dogs. In a matched group of six other dogs, the implants were left in overreamed canals without bone graft. After six weeks the interface shear strength of grafted Ti-coated implants had significantly increased compared to the nongrafted Ti implants. However, HA coating used without bone graft was capable of enhancing the bone-implant interface shear strength to nearly the same degree. The fixation of grafted Ti- and HA-coated implants was equal. No significant difference in implant fixation was found between osteopenic and control bone. Histomorphometric evaluation of mineralizing surfaces in direct contact with the implant confirmed the results from the push-out test. Bone-implant fixation when using allogeneic fresh-frozen cancellous bone graft in osteopenic and control bone was enhanced by hydroxyapatite coating but the HA coating alone appeared to offer almost the same improvement in anchorage in 2-mm defects. Loss of bone stock around loose prosthetic implants often requires bone grafting. However, because of anatomic constraints in joint prosthetic surgery, a complete filling of defects with bone graft is difficult, and areas of gaps between bone and implant will remain. Provided mechanical stability of the prosthesis, the results reported here suggest that these areas will probably be filled early with new mineralizing bone if the prosthesis is coated with a thin layer of hydroxyapatite.

Animals↗

Fixation of titanium and hydroxyapatite-coated implants in arthritic osteopenic bone.

Retrieval studies of porous-coated prostheses have demonstrated deficient bony ingrowth in high percentages. Possible reasons for this are lack of initial mechanical stability and the presence of osteopenia. The authors studied ingrowth of osteopenic bone into titanium alloy (Ti) porous-coated implants with and without hydroxyapatite (HA) coating in an experimental dog model. Unilateral osteopenia of the knee with a 20% reduced bone density as judged by computed tomography (CT) scanning (P less than .001) was induced in 12 mature dogs by weekly intraarticular injections of Carragheenin into the right knee for 12 weeks, with the left knee serving as control. Ti porous-coated cylinders were inserted in press-fit bilaterally in the lateral femoral condyles in six dogs. HA-coated titanium plugs were implanted similarly in another sex-, age-, and weight-matched group of six dogs. Bony ingrowth after 4 weeks was significantly reduced for Ti implants in osteopenic bone compared to control bone, but HA-coated implants were covered by equal amounts of bone tissue. Bone-implant shear strength of Ti implants also was reduced in osteopenic bone compared to control bone. In control bone, the anchorage of Ti implants was stronger than HA-coated implants, whereas the fixation of Ti and HA-coated implants was equal in the osteopenic bone. The results demonstrate that the bony fixation of Ti porous-coated implants is weakened by the presence of experimentally induced osteopenia. However, the fixation of HA-coated implants was not affected by the osteopenic condition in the surrounding bone. The fixation of Ti and HA-coated implants was equal in osteopenic bone, whereas the fixation of Ti porous-coated implants was superior to that of HA-coated implants in control bone.

Animals↗

Bone disorder in men with chronic alcoholism: a reversible disease?

Disturbances in bone metabolism and histology have been recognized in chronic alcoholism. It has not been established whether they are reversible and the cause remains unclear. We studied various serum and urine variables (including serum PTH, calcium, D-vitamins, and osteocalcin concentrations), bone mineral content, and bone histomorphometrics in men who at present abused alcohol and compared the results to those from men who previously had abused alcohol but who had abstained from alcohol for at least 2 yr and from normal men. No significant differences were found in bone mineral content at the two measuring sites (distal forearm, lumbar spine) between drinkers, abstainers, and controls though a considerable proportion of both current drinkers and abstainers had subnormal values. Bone formation rate and turnover (expressed by the activation frequency) was significantly reduced in the current drinkers who also had lower serum PTH, 1,25-dihydroxycholecalciferol, and osteocalcin concentrations. Men who had abstained from alcohol consumption for at least 2 yr had results similar to those from normal men, suggesting that the disturbances in bone metabolism in men abusing alcohol are reversible. The decrease in bone turnover in the drinkers may be explained by the observed reduction in plasma PTH concentration or a direct toxic effect of ethanol on bone tissue leading to a deficient recruitment of osteogenic cells.

Alcoholism↗

Histologic analysis of a retrieved hydroxyapatite-coated femoral prosthesis.

A hydroxyapatite-coated hip hemi-prosthesis was retrieved from a 98-year-old osteoporotic woman 12 weeks after implantation. Histologic analysis revealed bone and fibrous tissue almost evenly distributed around the surface of the implant circumference. Quantitative histologic analysis showed that 48% of the hydroxyapatite surface was covered by bone. Fibrous tissue covered 30% of the prosthetic surface, and 20% of the surface had no tissue coverage. Scanning electron microscopy showed direct contact without any clear boundary between the newly formed bone and the hydroxyapatite ceramic.

Aged↗

Gap healing enhanced by hydroxyapatite coating in dogs.

During prosthetic implantation, gaps between the implant surface and the surrounding bone may occur resulting in reduced implant stability. In these instances bone-conductive materials might augment the formation of hosting bone into the pores of the implant and insure earlier implant stabilization and fixation by bony ingrowth. Titanium-alloy cylinders with a porous-titanium-alloy plasma spray coating were implanted into the medial femoral condyles in six mature dogs. In another group of six dogs, matched in age, weight, and gender, hydroxyapatite (HA) coated implants were used. All implants were surrounded by a 1-mm gap. Unilateral osteopenia of the knee, with a 20% reduction of bone density as judged by computed tomography scanning, was induced by 12 weekly intraarticular injections of carrageenin into the right knee before surgery. Four weeks after implantation, the HA-coated implants were compared to the parent porous-titanium implants by mechanical testing and histomorphometry. A marked positive influence of HA coating on bone mineralization and the strength of the interfacial bone between the bone and implant was found. The increment in interface shear strength and shear stiffness was three- to fivefold in osteopenic bone and two-fold in control bone. Coating of an unloaded porous-titanium-coated implant with HA accelerates the rate of bone ingrowth and thereby provides relatively high, early interfacial shear strengths in the presence of an initial gap between bone and implant even in the presence of osteopenic host bone.

Animals↗

Hydroxyapatite coating enhances fixation of porous coated implants. A comparison in dogs between press fit and noninterference fit.

Intimate contact at the bone-porous surface interface is not always achievable in noncemented prosthetic implantation. We investigated the effect of hydroxyapatite (HA) coating on skeletal attachment in noninterference fit 4 weeks after implantation in 6 mature dogs. The push-out test of HA-coated implants surrounded by a 1-mm gap showed a twofold increased shear strength and fivefold increased shear stiffness compared with titanium alloy (Ti) coated implants. The fixation of Ti implants was reduced by two thirds when inserted in a gap as compared with press fit, whereas HA-coated implants in gap showed anchorage close to implants in press fit. Only minor differences were found between HA and Ti implants in press fit. Histomorphometric analysis showed a significant increase in bone in direct contact to HA-coated implant as compared with Ti implants inserted both in gap and press fit. The study indicates that tightness of surgical fit is an important factor for sufficient fixation of the implant. However, our results demonstrate that hydroxyapatite coating almost eliminates the negative influence of noninterference fit between bone and unloaded implant.

Animals↗

The rhythmic relation between antler and bone porosity in Danish deer.

The interrelationship between porosity of antlers and metacarpal bones and annual physiologic osteopenia has been investigated in mature Danish male Roe deer (Capreolus capreolus). The study shows a highly significant inverse correlation between porosity in the antlers and porosity in the metacarpal bones, indicating a necessary calcium mobilization from the bones for the mineralization of the antlers. The investigation further suggests that the decreasing porosity of the antlers throughout the antler period, reaching very low values, may be the cause of antler shedding.

Animals↗