PubMed Health⌕ Search

Biomedical subjects

H C Costa

Publications and source records attributed to H C Costa.

4 recordsLinked to original sources

[The implantation of VDD pacemakers with a single electrode--a comparative study. The experience of the last 5 years].

OBJECTIVE: To compare the epidemiological characteristics and immediate results of all first single lead VDD pacemaker (PM) implantations with those of an equal number of dual chamber DDD PM, implanted during a 5-year period in a tertiary-care hospital. POPULATION AND METHODS: A total of 41 patients (pts) (25 males, mean age of 69.0 +/- 11.8 years) underwent a VDD PM implantation, from 30-11-92 to 15-9-97. This group was compared with an equal number of patients (28 males, mean age of 69.9 +/- 7.31 years) with a DDD PM implanted in the same period, selected by a criterion of immediate temporal proximity of procedure. For each patient we collected the clinical and electrocardiographic (ECG) indications for PM implantation, parameters of atrial (AS) and ventricular (VS) sensing and ventricular pacing (VP), X-ray exposure time (XRT) and complications. RESULTS: In the VDD group, 46.3% of the patients had syncope, 51.2% had complete AV block on the ECG, and 14.6% were PM-dependent. Analyzed procedure-related parameters were as follows: P-wave amplitude: 2.1 +/- 0.6 V; AS threshold: 1.2 +/- 0.7 V; R-wave amplitude: 9.1 +/- 3.3 V; VS threshold: 7.0 +/- 2.0 V; VP thresholds: 0.68 +/- 0.24 mA, 0.43 +/- 0.12 V (for a spike duration of 0.5 ms); ventricular impedance: 644.9 +/- 132.0 ohm; XRT; 7' 43" +/- 8' 23". There were two minor complications, for an incidence of 4.9% (one local hematoma and a vagal reaction). In the DDD group the clinical and ECG characteristics were similar, but there was a 22.0% prevalence of sinus-node dysfunction, VS 0% in the VDD group). The P-wave amplitude and AS threshold were significantly (p < 0.005) better (2.8 +/- 0.9 V and 2.8 +/- 0.9 V respectively). The other parameters were similar to those of the VDD group. CONCLUSIONS: The immediate results of VDD PM implantation are good and comparable with those of DDD PM, although with worse acute AS parameters.

Aged↗

[Permanent pacing in childhood: a review of 11 years of experience].

STUDY OBJECTIVE: To review our eleven year experience in the implantation and follow-up of permanent Pacemakers in the paediatric age group. DESIGN: Retrospective study. SETTING: Children submitted to permanent cardiac Pacing implantation and accompanied in the Pacing Center of the Hospital de Santa Maria. PATIENTS: Children from both sexes, aged from neonate to 14 years old, with brady-dysrhythmia and indication for permanent cardiac Pacing implantation. MATERIAL AND METHODS: From November 1980 to September 1991, 16 children had permanent Pacemaker implantation. We describe the clinical and electrocardiographic characteristics of the population, mode of Pacing used, technical data from the implantation and evolution. RESULTS: One children died due to associated cardiac defect not related to the Pacemaker. The other 15 children remain in follow-up with normofunctioning Pacemakers and free of symptoms. We had to perform 11 reinterventions in 8 children due to generator or electrode problems (28,2 months reintervention interval). CONCLUSIONS: Improvements in Pacemaker technology and a careful technique of implantation can significantly reduce the morbidity associated to permanent pacemaker implantation in this age group.

Adolescent↗

[Comparative study of various staining methods for mycobacteria].

The present paper intends to show what coloration method for mycobacteria is the better. Samples was assessed and processed by hot Ziehl-Neelsen, cold Ziehl-Neelsen, Ziehl Gabbet and Ziehl-Neelsen with alkaline metilene blue. After microscopy by five different persons the method selected were the cold Ziehl-Neelsen.

Bacteriological Techniques↗