Simultaneous determination of naphazoline, diphenhydramine and phenylephrine in nasal solutions by capillary electrophoresis.

A capillary zone electrophoresis (CZE) method has been developed to separate and quantitate naphazoline (NAPH), dyphenhydramine (DIP) and phenylephrine (PHE) in nasal solutions. Samples were diluted 1:25 in ultrapure water and injected at the anodic end. A central composite design has been used to optimise the experimental conditions for a complete and fast separation of the active ingredients studied. Critical parameters such as voltage, pH and buffer concentration have been studied to evaluate how they affect responses such as resolution and migration times. Separation was performed on a silica capillary with 75 microm I.D. and 70 cm total length at an applied voltage of 17.7 kV with a phosphate run buffer of pH 3.72 and 0.063 mol l(-1). Calibration curves were prepared for NAPH, DIP and PHE. For each analyte, the correlation coefficients were >0.999 (n=15). The RSD% of six replicate injections for each analyte were reasonably good. The method was applied to the quantitation of the three components in a commercial dosage form. The proposed method has the advantage of needing a very simple sample pretreatment and being faster than a typical HPLC chromatographic method.

Administration, Intranasal↗

Determination of dexamethasone and two excipients (creatinine and propylparaben) in injections by using UV-spectroscopy and multivariate calibrations.

The use of multivariate spectrophotometric calibration for the simultaneous determination of dexamethasone and two typical excipients (creatinine and propylparaben) in injections is presented. The resolution of the three-component mixture in a matrix of excipients has been accomplished by using partial least-squares (PLS-1). Notwithstanding the elevated degree of spectral overlap, they have been rapidly and simultaneously determined with high accuracy and precision (comparable to the HPLC pharmacopeial method), with no interference, and without resorting to extraction procedures using non-aqueous solvents. A simple and fast method for wavelength selection in the calibration step is used, based on the minimisation of the predicted error sum of squares (PRESS) calculated as a function of a moving spectral window.

Calibration↗

Sustained prediction ability of net analyte preprocessing methods using reduced calibration sets. Theoretical and experimental study involving the spectrophotometric analysis of multicomponent mixtures.

A newly developed multivariate method involving net analyte preprocessing (NAP) was tested using central composite calibration designs of progressively decreasing size regarding the multivariate simultaneous spectrophotometric determination of three active components (phenylephrine, diphenhydramine and naphazoline) and one excipient (methylparaben) in nasal solutions. Its performance was evaluated and compared with that of partial least-squares (PLS-1). Minimisation of the calibration predicted error sum of squares (PRESS) as a function of a moving spectral window helped to select appropriate working spectral ranges for both methods. The comparison of NAP and PLS results was carried out using two tests: (1) the elliptical joint confidence region for the slope and intercept of a predicted versus actual concentrations plot for a large validation set of samples and (2) the D-optimality criterion concerning the information content of the calibration data matrix. Extensive simulations and experimental validation showed that, unlike PLS, the NAP method is able to furnish highly satisfactory results when the calibration set is reduced from a full four-component central composite to a fractional central composite, as expected from the modelling requirements of net analyte based methods.

Calibration↗

Enhanced synchronous spectrofluorometric determination of tetracycline in blood serum by chemometric analysis. Comparison of partial least-squares and hybrid linear analysis calibrations.

Tetracycline has been determined in human serum samples by a combination of: (1) synchronous fluorescence spectra of whole sera treated with Mg2+, and (2) the multivariate calibration methods of partial least-squares (PLS-1) and a variant of the recently introduced hybrid linear analysis (HLA), which does not require the knowledge of pure-component spectra. The calibration set was designed with 50 sera spiked with concentrations of tetracycline in the range 0.0-4.0 micrograms mL-1'. Studies concerning validation, precision, accuracy and figures of merit (selectivity, sensitivity and limit of determination) were also carried out. A novel wavelength-selection procedure was applied to minimize the effect of nonmodeled interferents present in serum samples containing bilirubin, triglycerides, and salicylate. Overall, the performance of the newly developed HLA approach seems to be better than that of PLS-1.

Calibration↗

Simultaneous multivariate spectrophotometric analysis of paracetamol and minor components (diphenhydramine or phenylpropanolamine) in tablet preparations.

The use of multivariate spectrophotometric calibration is reported for the analysis of two decongestant tablets, where paracetamol is the principal component and diphenhydramine or phenylpropanolamine are the minor components. The resolution of these mixtures has been accomplished without prior separation or derivatisation, by using partial least-squares (PLS-1) regression analysis of electronic absorption spectral data. Although the molar ratios of paracetamol to the minor components were 38:1 and 25:1 respectively, the latter have been determined with high accuracy and precision, and with no interference from tablet excipients. PLS is able to take into account small deviations of paracetamol from linearity in the studied concentration range. The application of classical least-squares (CLS) analysis yields unsatisfactory results, due to the low absorbances of the minor components within the range where all components obey Beer's law.

Acetaminophen↗

Simultaneous determination of rifampicin, isoniazid and pyrazinamide in tablet preparations by multivariate spectrophotometric calibration.

The use of multivariate spectrophotometric calibration is presented for the simultaneous determination of the active components of tablets used in the treatment of pulmonary tuberculosis. The resolution of ternary mixtures of rifampicin, isoniazid and pyrazinamide has been accomplished by using partial least squares (PLS-1) regression analysis. Although the components show an important degree of spectral overlap, they have been simultaneously determined with high accuracy and precision, rapidly and with no need of nonaqueous solvents for dissolving the samples. No interference has been observed from the tablet excipients. A comparison is presented with the related multivariate method of classical least squares (CLS) analysis, which is shown to yield less reliable results due to the severe spectral overlap among the studied compounds. This is highlighted in the case of isoniazid, due to the small absorbances measured for this component.

Antitubercular Agents↗