The influence of ventilation on reactions among indoor pollutants: modeling and experimental observations.

This study examines the influence of ventilation on chemical reactions among indoor pollutants. We have used a one compartment mass balance model to simulate unimolecular and bimolecular reactions occurring indoors. The initial modeling assumes steady-state conditions. However, at low air exchange rates, there may be insufficient time to achieve steady-state. Hence we have also modeled non steady-state scenarios. In the cases examined, the results demonstrate that the concentrations of products generated from reactions among indoor pollutants increase as the ventilation rate decreases. This is true for unimolecular and bimolecular reactions, regardless of whether the pollutants have indoor or outdoor sources. It is also true even when one of the pollutants has an outdoor concentration that displays large diurnal variations. We have supplemented the modeling studies with a series of experiments conducted in typical commercial offices. The reaction examined was that between ozone and limonene. The ozone was present as a consequence of outdoor-to-indoor transport while the limonene originated indoors. Results were obtained for low and high ventilation rates. Consistent with the modeling studies, the concentrations of monitored products were much larger at the lower ventilation rates (even though the ozone concentrations were lower). The potential for reactions among indoor pollutants to generate reactive and irritating products is an additional reason to maintain adequate ventilation in indoor environments.

Air Pollution, Indoor↗

Concentrations of volatile organic compounds at a building with health and comfort complaints.

For four separate periods over a 1-yr span, the concentrations of volatile organic compounds (VOCs) have been measured at a facility with a history of occupant complaints. The reported symptoms were characteristic of "sick building syndrome." This study was initiated to determine if VOC levels were higher than those measured in "complaint-free" buildings and, if so, to identify sources and other factors that might contribute to the elevated concentrations. VOCs were collected with passive samplers, using a sampling interval that lasted from 3 to 4 weeks. Following collection, the samplers were extracted, and the compounds in the extract were separated and identified using standard gas chromatographic-mass spectrometric procedures. Over 40 different organic compounds with concentrations in excess of 1 microgram/m3 were identified; several species had values greater than 100 micrograms/m3. For each of the first three sampling periods, the total concentration of VOCs detected using this methodology was in excess of 3 mg/m3. Sources of the identified compounds included cleaning products, floor wax, latex paints, and reentrained motor vehicle exhaust. However, the dominant source was the hydraulic system for the buildings' elevators. Compounds were volatilizing from the hydraulic fluid used in this system. Neither the elevator shafts nor the mechanical room housing the fluid reservoirs were vented to the outside. The problem was compounded by the relatively small amount of outside air used for ventilation at this facility (less than 6 L/sec [12 cfm]/occupant or about 1/4 air change/hr). At such low ventilation rates, compounds with strong sources can achieve high steady-state concentrations within the facility. Recommendations have been made to reduce the VOC levels at this site. Although implementing the recommendations will be costly, even a slight improvement in employee productivity will offset these costs.

Air Pollutants↗

Indoor ozone exposures.

Indoor and outdoor ozone concentrations were measured from late May through October at three office buildings with very different ventilation rates. The indoor values closely tracked the outdoor values, and, depending on the ventilation rate, were 20 to 80 percent of those outdoors. The indoor/outdoor data are adequately described with a mass balance model. The model can also be coupled with reported air exchange rates to estimate indoor/outdoor ratios for other structures. The results from this and previous studies indicate that indoor concentrations are frequently a significant fraction of outdoor values. These observations, and the fact that most people spend greater than 90 percent of their time indoors, indicate that indoor ozone exposure (concentration X time) is greater than outdoor exposure for many people. Relatively inexpensive strategies exist to reduce indoor ozone levels, and these could be implemented to reduce the public's total ozone exposure.