PubMed Health⌕ Search

Biomedical subjects

H C Yoon

Publications and source records attributed to H C Yoon.

At least 19 recordsLinked to original sources

Spiral versus electron-beam CT for coronary artery calcium scoring.

PURPOSE: To determine differences in coronary artery calcium detection, quantification, and reproducibility, as measured at electron-beam computed tomography (CT) and subsecond spiral CT with retrospective electrocardiogram gating in an asymptomatic adult population. MATERIALS AND METHODS: Seventy subjects asymptomatic for coronary heart disease underwent both electron-beam CT and subsecond spiral CT. In all subjects, two images each were obtained with both scanners. Two experienced readers using three different algorithms scored each of the four scans: one score for the electron-beam CT images and two scores for the spiral CT images. RESULTS: With a 130-HU threshold for the quantification of calcium, there were no significant differences in interscan and interobserver variation in calcium scores between the electron-beam CT and spiral CT images. There was greater interobserver (P <.001) and interscan (P <.03) variation in scores when a 90-HU threshold was used for spiral CT images. With a 130-HU threshold, when calcium scores were used for clinical risk stratification, there was a significant difference between the results obtained with electron-beam CT and those obtained with spiral CT (P <.05). CONCLUSION: Spiral CT has not yet proved to be a feasible alternative to electron-beam CT for coronary artery calcium quantification. There are systematic differences between calcium scores obtained with single-detector array subsecond spiral CT and those obtained with electron-beam CT.

Adult↗

Percutaneous sclerotherapy for congenital venous malformations in the extremities.

Between January 1991 and January 1998, a total of 15 patients underwent direct injection sclerotherapy for painful peripheral venous malformations. Duplex ultrasonography or venography was used in all cases for the detection and localization of tortuous venous structures. Direct injection with absolute ethyl alcohol was performed in 12 patients, and Sotradecol or sodium morrhuate was used in 5 patients. Provocative lidocaine testing was used in 2 patients in whom major nerves were in proximity to the malformations. All patients underwent follow-up in the clinic with duplex examination after each sclerotherapy. Clinical symptoms of all patients improved during average follow-up of 2.5 years (range: 3 months to 6 years.) Duplex examination was useful in detecting the venous component including the size and course of veins, which were often less well seen on magnetic resonance imaging. Duplex study was helpful in follow-up after sclerotherapy in all patients. Direct injection sclerotherapy is an acceptable treatment modality for venous malformations. Complications are manageable, and regular follow-up with Duplex is helpful.

Adolescent↗

Functionalization of a poly(amidoamine) dendrimer with ferrocenyls and its application to the construction of a reagentless enzyme electrode.

Poly(amidoamine) dendrimers having various degrees of modification with the redox-active ferrocenyls were prepared by controlling the molar ratio of ferrocenecarboxaldehyde to amine groups of dendrimers. By alternate layer-by-layer depositions of partial ferrocenyl-tethered dendrimers (Fc-D) with periodate-oxidized glucose oxidase (GOx) on a Au surface, an electrochemically and enzymatically active multilayered assembly of enzyme was constructed. The resulting GOx/Fc-D multilayer-associated electrodes were electrochemically analyzed, and the surface concentration of ferrocenyl groups, active enzyme coverage, and sensitivity were estimated. A 32% dendrimer modification level of surface amines to ferrocenyls was found to be an optimum in terms of enzyme-dendrimer network formation, electrochemical interconnectivity of ferrocenyls, and electrode sensitivity. With the prepared Fc(32%)-tethered dendrimers, mono- and multilayered GOx/Fc-D electrodes were constructed, and their electrochemical and catalytic properties were characterized. The bioelectrocatalytic signals from the multilayered GOx/Fc-D electrodes were shown to be directly correlated to the number of deposited bilayers. From this result, it seems that the electrode sensitivity is directly controllable, and the multilayer-forming strategy with partial ferrocenyl-tethered dendrimers is useful for the construction of reagentless biosensors.

Biosensing Techniques↗

Affinity biosensor for avidin using a double functionalized dendrimer monolayer on a gold electrode.

We have developed an affinity biosensor system based on avidin-biotin interaction on a gold electrode. As the building block of an affinity-sensing monolayer, a fourth-generation (G4) poly(amidoamine) dendrimer having partial ferrocenyl-tethered surface groups was prepared and used. The unmodified surface amine groups from dendrimers were functionalized with biotinamidocaproate, and the biotinylated and electroactive dendritic monolayer was constructed on a gold electrode for the affinity-sensing surface interacting with avidin. An electrochemical signal from the affinity biosensor was generated by free glucose oxidase in electrolyte, depending on the degree of coverage of the sensing surface with avidin. The sensor signal decreased correlatively with increasing avidin concentration and approached a minimum level when the sensing surface was fully covered with avidin. The detection limit of avidin was about 4.5 pM, and the sensor signal was linear ranging from 1.5 pM to 10 nM under optimized conditions. From the kinetic analysis using the biotinylated glucose oxidase, an active enzyme coverage of 2.5 x 10(-12) mol/cm(2) on the avidin-pretreated surface was registered, which demonstrates the formation of a spatially ordered and compact protein layer on the derivatized electrode surface.

Animals↗

Fluoroscopically guided percutaneous placement of large-bore gastrostomy and gastrojejunostomy tubes: review of 109 cases.

PURPOSE: To evaluate our experience with percutaneous placement, management, and complications of large-bore (20-24 F) gastrostomy and gastrojejunostomy feeding tubes. MATERIALS AND METHODS: A retrospective review was performed on 109 consecutive patients who underwent placement of percutaneous large-bore feeding tubes between January 1994 and May 1998. Data were collected with respect to underlying illness, technical success, number of replaced tubes, and immediate and late complications. No patient had a small-bore tube placed during this series. RESULTS: A total of 109 cases were reviewed. Immediate follow-up within the first 2 weeks was available for all 109. Follow-up after 2 weeks was available for 61 (56%) patients. Tubes were placed in patients aged 15 to 94 years. Neurologic dysfunction from a variety of causes was the most common underlying illness and occurred in 52% of patients. There were nine (8.3%) immediate, treatable complications: three major and six minor. There was one procedure-related death (0.9%). Persistent fistula tracts following tube removal occurred in three patients (4.9%). Balloon rupture was the most common reason for tube exchange (40.7%). CONCLUSION: Percutaneous large-bore gastrostomy and gastrojejunostomy tubes are safe to place and have technical success, morbidity, and mortality rates comparable to those of tubes placed surgically or endoscopically as well as small-bore tubes placed with fluoroscopic guidance.

Female↗

Refractory abdominal-cutaneous fistulas or leaks: percutaneous management with a collagen plug.

BACKGROUND: We report the results of abdominal-cutaneous fistula tract occlusion with a collagen plug in a series of patients with fistulas or leaks refractory to conservative therapy. STUDY DESIGN: Seven patients were found to have persistent fistula or leak after percutaneous drainage of abdominal pelvic fluid collections. All patients but one were refractory to surgical or percutaneous drainage. Under fluoroscopic guidance, modified Vasoseal (Datascope Inc, Montvale, NJ) collagen plugs were deployed into the fistulas using catheter-directed techniques. The plugs were split longitudinally to fit into an 8F or 9F peel-away sheath, placed into the fistula, and deployed. Results were tabulated and patients were followed up. RESULTS: Six of seven patients undergoing fluoroscopically guided, catheter-directed tract occlusion had resolution of the fistula, with no evidence of fistula or abscess recurrence from 30 to 180 days after closure. There were no procedural complications. The technique was unsuccessful in dosing a gastrocutaneous fistula after removal of a large-bore gastrostomy tube; this failure was believed to be secondary to the short length and large caliber of the tract in a patient with hypercortisolemia. CONCLUSIONS: Closure of abdominal-cutaneous fistula tracts by occlusion with a modified Vasoseal collagen plug shows promise in the management of fistulas refractory to catheter drainage.

Abdomen↗

Percutaneous delivery of a heparin-impregnated collagen stent-graft in a porcine model of atherosclerotic disease.

RATIONALE AND OBJECTIVES: To develop collagen stent-grafts impregnated with heparin to improve the biocompatibility of endovascular stents and to design a percutaneous delivery system for graft deployment in a swine model. METHODS: Heparin-impregnated collagen stent-grafts were deployed, and follow-up angiograms were obtained every 15 minutes for 90 minutes to assess acute thromboses and again at 2 and 4 weeks afterward to assess patency. If stenosis or occlusion was detected at the 2-week evaluation, guidewire passage across the lesion was attempted and angioplasty was performed. If stenosis or occlusion was present at the 4-week evaluation, only guidewire passage was attempted; thereafter, the animals were killed and the stent-grafts were harvested and reviewed by a vascular pathologist. RESULTS: Group A represents a feasibility study to optimize the deployment method applied in groups B and C. Fifteen of 17 stent-grafts were successfully deployed using this method. In group B, 89% of grafts were successfully deployed; 12% were patent at 2 weeks and none at 4 weeks. In group C, a 10-minute inflation time was added to the deployment procedure; 88% of grafts were successfully deployed and 28% were patent at 2 weeks and 14% at 4 weeks. Extensive luminal thrombosis and myointimal hyperplasia were present in every case. CONCLUSIONS: A method was developed for percutaneous implantation of collagen stent-grafts into peripheral vessels. The heparin-impregnated grafts did not prevent vessel restenosis. Modification of the graft-processing technique may improve patency.

Animals↗

Interscan variation in coronary artery calcium quantification in a large asymptomatic patient population.

OBJECTIVE: We evaluated interscan variation in coronary artery calcium scores in a large screening population as determined by electron beam CT. MATERIALS AND METHODS: One thousand patients (average age, 53 years; age range, 18-85 years) who were asymptomatic for coronary artery disease underwent two consecutive scans of the heart on an electron beam CT scanner. Scans were performed with ECG gating, breath-hold, 3-mm collimation, and 100-msec exposure. Two contiguous pixels with density values greater than 130 H were used as the minimum criterion for a calcific lesion. The calcium score was determined on a vessel-by-vessel basis for both scans of each patient. Interscan variation in calcium and vessels involved with calcification was evaluated on the basis of age, sex, and average calcium score. RESULTS: The percentage of difference between calcium scores in scans was 28.4% and 43.0% for women and men, respectively. For the individual epicardial arteries (left main, left anterior descending, circumflex, and right coronary), the percentage of difference for calcium scores was 20.2-24.2% for women and 30.5-44.9% for men. A difference between the two scans in at least one vessel of the total coronary arteries identified with calcium was noted in 31% of patients. CONCLUSION: Interscan variability in calcium scores may be important in the determination of risk stratification. Subjects with a nonzero calcium score may benefit from undergoing two scans at the time of initial imaging.

Adolescent↗

MRI of thermally denatured blood: methemoglobin formation and relaxation effects.

Focal regions of T1-shortening have been observed in magnetic resonance imaging (MRI)-monitored thermal ablations of perfused tissues. The aims of this study were two-fold: to find evidence for heat-induced conversion of hemoglobin (Hb) to methemoglobin (mHb), and to investigate the effects of heat treatment of in-vitro blood components upon their MR relaxation times. Spectrophotometric studies were performed to confirm the heat-induced formation of methemoglobin. Preparations of whole and fractionated blood, previously submitted to elevated temperatures of 40 degrees C to 80 degrees C, were imaged and the relaxation times were calculated. Optical absorption spectra of samples containing free Hb, heated to 60 degrees C, showed increased light absorption at 630 nm, evident of mHb presence. Short T1 values in whole blood (1.13 s) and packed red blood cell (0.65 s) compartments, heated at 60 degrees C, compared to their baseline values (1.62 s and 0.83 s, respectively), were attributed to mHb formation. In relation to MRI-guided thermal interventions, these results suggest a possible explanation for observation of hyperintense regions on T1-weighted images.

Animals↗

Clinical outcomes of patients after a negative spiral CT pulmonary arteriogram in the evaluation of acute pulmonary embolism.

PURPOSE: To examine 6-month clinical outcomes of patients after acquisition of a spiral computed tomography (CT) pulmonary arteriogram interpreted as negative for acute pulmonary embolism (PE). MATERIALS AND METHODS: A retrospective review was performed on a consecutive series of 143 patients who underwent spiral CT pulmonary arteriography for possible acute PE during a 19-month period. All studies were performed on a HiSpeed Scanner with use of 3-mm collimation with a pitch between 1.3 and 2.0, depending on patient size. All imaging was performed during dynamic contrast material injection at rates between 3.0 and 4.0 mL/sec, timed to peak pulmonary arterial enhancement. For the studies interpreted as negative for PE through the segmental (fourth order) pulmonary arteries, follow-up data were collected by telephone interviews with patients or surviving relatives, and by medical record reviews. RESULTS: Among 143 patients, 22 studies (15%) were positive for PE, eight (6%) were suboptimal to exclude PE to the segmental artery level, and 113 (79%) were interpreted as negative for acute PE. Among the 113 negative studies, 13 patients were lost to follow-up, leaving a study population of 100 patients. Eighty-one patients were alive a minimum of 6 months after acquisition of a negative spiral CT pulmonary arteriogram (mean, 9 months; range, 6-24 months) and were without interim diagnosis of PE. Nineteen patients died within the follow-up period after a negative spiral CT pulmonary arteriogram (mean, 3 months; range, 0-8 months); however, in none of these cases was acute pulmonary embolus reported as the cause of death. No documented PE was identified by subsequent imaging studies or autopsy within the study population. CONCLUSION: A series of 100 patients with a negative spiral CT pulmonary arteriogram did not experience significant morbidity and mortality as a result of pulmonary embolic disease within a 6-month follow-up period.

Adult↗

Gadolinium-enhanced breathhold three-dimensional time-of-flight renal MR angiography in the evaluation of potential renal donors.

PURPOSE: To evaluate the utility of gadolinium-enhanced three-dimensional (3D) time-of-flight (TOF) magnetic resonance angiography (MRA) of the renal arteries in the evaluation of potential renal donors. MATERIALS AND METHODS: Fifty consecutive patients underwent gadolinium-enhanced 3D-TOF MRA of the renal arteries as part of their evaluation as possible renal donors. All imaging was performed on a 1.5-T system with use of a torso phased-array coil. Conventional T1-weighted axial spin-echo and T2-weighted axial fast spin-echo imaging was performed to evaluate the renal parenchyma. Coronal dynamic MRA was performed during bolus injection of 40 mL of gadolinium with use of a 3D-TOF sequence requiring a breathhold of approximately 30 seconds. Maximum-intensity-projection reconstructions were obtained of the renal arterial and venous anatomy. All studies were prospectively evaluated by a single radiologist experienced with body MRA. Intraoperative findings were used as the reference standard in 35 patients. To evaluate interobserver variability, each examination was evaluated for image quality, renal artery number, and anatomy by two radiologists experienced with MRA and blinded to the other's interpretations and surgical results. RESULTS: Ninety-eight percent of all MRAs were graded as diagnostic quality (Kappa value = 0.38; P < .05). Multiple renal arteries were identified in 29 (29%) of 100 kidneys. Four of 50 patients studied (8%) had renal parenchymal abnormalities identified with MR imaging. Sensitivity and specificity for accessory renal artery detection was 71% and 95%, respectively. Overall, accuracy for MRA in determining renal artery number was 90%. CONCLUSION: Gadolinium-enhanced breathhold 3D-TOF renal MRA is sufficient to assess the renal arteries in potential donors.

Adult↗

Electron-beam CT: the effect of using a correction function on coronary artery calcium quantitation.

PURPOSE: The purpose of the study was to determine if use of a correction function derived from a phantom with known calcium density reduces variation in coronary artery calcium scores measured with electron-beam computed tomography (CT) and to evaluate the influence of body girth, as measured by body mass index (BMI), on coronary artery calcium-score variability in a clinical screening cohort. MATERIALS AND METHODS: Two hundred fifty consecutive patients underwent two electron-beam CT examinations with a standardized phantom. Region-of-interest (ROI) measurements of the phantom were correlated with the patient BMI. In a subset of 28 patients with low but positive coronary artery calcium scores, ROI values of the phantom were used as a correction for signal attenuation. RESULTS: Patient BMI was not significantly correlated to signal attenuation. Application of a correction function resulted in a small but insignificant decrease in interscan coronary artery calcium-score variation. The interscan coronary artery calcium score variation was 24.5% +/- 23.9; it decreased to 24.3% +/- 21.6 with use of the 75 mg/cm3 portion of the phantom and to 22.2% +/- 21.4 with use of the 150 mg/cm3 portion of the phantom. CONCLUSION: The use of a coronary artery calcium phantom does not reduce interscan variation sufficiently to warrant regular clinical usage. Interscan variation in the coronary artery calcium score is not significantly influenced by patient BMI.

Analysis of Variance↗

Renal artery stenosis: evaluation with conventional angiography versus gadolinium-enhanced MR angiography.

PURPOSE: To evaluate the interobserver and intermodality variability of conventional angiography and gadolinium-enhanced magnetic resonance (MR) angiography in the assessment of renal artery stenosis. MATERIALS AND METHODS: Fifty-four patients underwent conventional angiography and gadolinium-enhanced three-dimensional gradient-echo MR angiography. Three angiographers blinded to each other's interpretations and the MR angiographic findings assessed the conventional angiograms for renal artery stenosis. Similarly, three blinded MR imagers evaluated the MR angiograms. RESULTS: Interobserver variability for the degree of renal artery stenosis in the 107 kidneys evaluated was not significantly different between the two modalities. The mean SD of the degree of stenosis was 6.9% at MR angiography versus 7.5% at conventional angiography (alpha < or = .05, P > .05). In 70 kidneys (65%), the average degree of stenosis reported by the readers for the two modalities differed by 10% or less. In 22 cases (21%), the degree of stenosis was overestimated with MR angiography by more than 10% relative to the results of conventional angiography. In 15 cases (14%), the degree of stenosis was underestimated with MR angiography by more than 10%. CONCLUSION: Gadolinium-enhanced MR angiography permits evaluation of renal artery stenosis with an interobserver variability comparable with that of conventional angiography.

Angiography↗

Detection of pulmonary emboli at the segmental and subsegmental level with electron-beam CT: validation in a porcine model.

RATIONALE AND OBJECTIVES: The authors evaluated the sensitivity of electron-beam computed tomography (CT) in the detection of segmental and subsegmental pulmonary artery emboli in a porcine model. MATERIALS AND METHODS: Twenty-one segmental and subsegmental branch pulmonary arteries in five swine were selectively catheterized and embolized with gelatin sponge pledgets. The presence of emboli was confirmed by means of contrast material-enhanced angiography. Contrast-enhanced CT scans of the pulmonary arteries were then obtained with 3-mm collimation, 2-mm table travel between sections, and an imaging time of 100 msec per section. Contrast material was injected at a rate of 2-3 mL/sec, depending on the animal's weight, with a total dose of 60 mL for each scan. Cardiac-gated and nongated scans were obtained, but breath holding was not possible in these animals. RESULTS: Contrast-enhanced electron-beam CT scanning allowed correct prospective identification of 18 of 21 emboli in the segmental and subsegmental branches of the pulmonary arteries. The overall sensitivity was 86%. Cardiac gating subjectively improved image quality but did not result in greater sensitivity in the detection of emboli. The level of sensitivity was not affected by the use of breath holding. CONCLUSION: Contrast-enhanced electron-beam CT is a sensitive method for the detection of embolism in the segmental and subsegmental pulmonary arteries.

Angiography↗

Determining factors in the iron status of adult women in the SU.VI.MAX study. SUpplementation en VItamines et Minéraux AntioXydants.

The iron status of a national sample of adults living in France and participating in the SU.VI.MAX cohort, was assessed using serum ferritin and hemoglobin concentrations. Complete data were obtained for 6648 women 35-60 y old and for 3283 men 45-60 y old. Assessment of iron dietary intakes was realized on a subsample of 3111 women and 2337 men who reported six 24 h dietary records during a one-year period; 22.7% of menstruating women and 5.3% of post-menopausal women presented a total depletion of iron stores (serum ferritin < 15 microg/l). Iron-deficient anemias were found in, respectively, 4.4% and less than 1% of these women. Three-quarters of the anemias were related to iron deficiency in menstruating women. In men, iron depletion and iron deficiency anemia were very rare. Post-menopausal women had much higher serum ferritin levels than menstruating women. In menstruating women, those using intrauterine devices had significantly lower serum ferritin levels than those without contraception, and much lower than those using oral contraception. The frequency of iron depletion reached 28.1% in women using intrauterine devices, but only 13.6% in those using oral contraceptives. The mean iron intake was 16.7 +/- 5.7 mg/d in men and 12.3 +/- 3.4 mg/d in women. Heme iron represented respectively, 11.1 and 10.4% of iron intake. Ninety-three percent of menstruating women had dietary iron intakes lower than recommended dietary allowances (RDA); 52.6% consumed less than two thirds of these RDA. In post-menopausal women and men, respectively 27.7% and 3.6% had dietary intakes lower than RDA. Serum ferritin was positively correlated with meat, fish and total iron intake, and negatively correlated with dietary products consumption, calcium and fiber intake.

Adult↗

Coronary artery calcium: alternate methods for accurate and reproducible quantitation.

RATIONALE AND OBJECTIVES: The aim of this study was to determine a more precise and accurate method of quantitating coronary artery calcium (CAC) detected with electron-beam computed tomography (CT) in patients with low CAC scores. MATERIALS AND METHODS: Two 40-section, 3-mm-collimation, electrocardiographically gated electron-beam CT examinations of the heart were performed in each patient. Fifty patients with average scores between 2 and 100, as determined with the conventional scoring algorithm, were selected. The modified conventional scoring algorithm was compared with two techniques: calculated calcium volume and approximated calcium mass. RESULTS: The percentage difference between scans ranged from 37.2% for the conventional scoring method to 28.2% and 28.4% for volume- and mass-based methods, respectively. Increasing lesion size thresholds does not improve quantitative precision and reduces accuracy in patients with small amounts of CAC. CONCLUSION: Quantification methods based on calcification volume or mass decrease score variation compared with the conventional scoring method, and increased size threshold does not improve accuracy.

Adult↗

Estimation of the left ventricular ejection fraction using a novel multiphase, dark-blood, breath-hold MR imaging technique.

OBJECTIVE: In this paper, we evaluate a recently proposed dual-phase dark-blood MR sequence for estimating the left ventricular ejection fraction, compare Simpson's method of estimation of ejection fraction with a model based on the biplane method, assess the reproducibility of both methods, and finally, test a semiautomated method for contouring the endocardial border. SUBJECTS AND METHODS: An MR pulse sequence was implemented to acquire cardiac images in both diastolic and systolic phases within a single breath-hold. A special magnetization preparation scheme rendered blood dark while a segmented acquisition allowed breath-hold scan times. Five healthy volunteers and five patients with cardiac disease were imaged. Ejection fractions were estimated using (1) long-axis and four-chamber biplane views with an ellipsoid model and (2) a series of short-axis views in combination with Simpson's model. These values of ejection fractions were then compared with values obtained from echocardiography. RESULTS: Estimates of ejection fractions obtained using biplane ellipsoid volume and Simpson's rule methods varied by 14% in healthy volunteers. However, for patients with severe cardiomyopathy, differences between the values of ejection fraction obtained with the two methods varied by as much as 150%. Ejection fraction estimates obtained from MR images with the biplane ellipsoid method and from echocardiography varied by approximately 14% for all subjects. Ejection fraction estimates obtained with the semiautomated algorithm agreed well with estimates obtained with manual contours made by experienced radiologists. Intraobserver variability was low for both the short-axis (3%) and biplane (4%) methods. However, interobserver variability of the biplane method (12%) exceeded that of the short-axis method (4%). Interexamination variability (9%) was the largest factor in determining the reproducibility of the ejection fraction estimates. CONCLUSION: Breath-hold dark-blood MR imaging technique with simultaneous acquisition of a series of short-axis views during systolic and diastolic phases permits rapid and accurate estimates of ejection fractions in healthy subjects and in patients. Model based biplane MR imaging methods are less reliable in patients with global cardiomyopathy. The estimation of ejection fractions can be automated using the proposed contouring algorithm and the dark-blood short-axis views.

Adult↗