PubMed Health⌕ Search

Biomedical subjects

H D Barone

Publications and source records attributed to H D Barone.

5 recordsLinked to original sources

Endoluminal aortic aneurysm repair using a balloon-expandable stent-graft device: a progress report.

We describe our experience with endoluminal repair of abdominal aortic aneurysms using the stent-graft device. Twenty-four patients underwent 25 procedures in the 27-month period ending December 31, 1992. Twenty-one of the patients were considered high-risk candidates for conventional surgical repair. The endoluminal stented grafts were aortoaortic in 16 procedures and unilateral aortoiliac in eight. One patient underwent a second procedure consisting of an ilioiliac graft to repair a separate common iliac artery aneurysm. Technical problems were primarily related to retrograde transluminal access across the iliac arteries, tortuous aneurysms, and misjudgments as to measurement of length. One patient died and another required secondary deployment of a distal stent at 4 months; subsequent aneurysm expansion mandated surgical replacement at 18 months. It is clear that this device and methodology will have to undergo further refinement before the technique is acceptable for wider clinical application. Current experience, however, is encouraging. Aneurysm exclusion with an endoluminal prosthesis is likely to become an important therapeutic alternative over the next several years.

Aged↗

Intraluminal bypass of abdominal aortic aneurysm: feasibility study.

This study evaluated the feasibility of treatment of abdominal aortic aneurysm (AAA) by means of intraluminal bypass. Artificial aortic aneurysms with fusiform Dacron conduits were created at surgery , a weft-knit Dacron tube with balloon-expandable stents attached at both ends was inserted transfemorally through a 14-F introducer sheath and expanded at the aneurysmal level by means of inflation of a coaxial balloon. The transluminal bypass successfully excluded the aneurysmal lumen immediately after placement. In two dogs, a postplacement aortogram revealed torsion of the graft that caused early occlusion. The six other dogs had a patent bypass at 6 months follow-up. Four of these dogs had evidence of kinking of the graft as a result of shrinkage of the prosthetic aneurysm. Histopathologic studies revealed that endothelialization was complete on the stents and partial on the graft surface. It is concluded that transluminal bypass of AAA is feasible in the dog model.

Animals↗

Transfemoral intraluminal graft implantation for abdominal aortic aneurysms.

This study reports on animal experimentation and initial clinical trials exploring the feasibility of exclusion of an abdominal aortic aneurysm by placement of an intraluminal, stent-anchored, Dacron prosthetic graft using retrograde cannulation of the common femoral artery under local or regional anesthesia. Experiments showed that when a balloon-expandable stent was sutured to the partially overlapping ends of a tubular, knitted Dacron graft, friction seals were created which fixed the ends of the graft to the vessel wall. This excludes the aneurysm from circulation and allows normal flow through the graft lumen. Initial treatment in five patients with serious co-morbidities is described. Each patient had an individually tailored balloon diameter and diameter and length of their Dacron graft. Standard stents were used and the diameter of the stent-graft was determined by sonography, computed tomography, and arteriography. In three of them a cephalic stent was used without a distal stent. In two other patients both ends of the Dacron tubular stent were attached to stents using a one-third stent overlap. In these latter two, once the proximal neck of the aneurysm was reached, the sheath was withdrawn and the cephalic balloon inflated with a saline/contrast solution. The catheter was gently removed caudally towards the arterial entry site in the groin to keep tension on the graft, and the second balloon inflated so as to deploy the second stent. Four of the five patients had heparin reversal at the end of the procedure. We are encouraged by this early experience, but believe that further developments and more clinical trials are needed before this technique becomes widely used.

Aged↗

[Structural changes in porcine valvular heterografts preserved in glutaraldehyde].

Ultrastructural studies were made of 7 glutaraldehyde-treated porcine valvular heterografts. Five prosthesis had been preserved for a period of 24 months. The remaining two, presented patched areas of different appearance and were eliminated at the routine control studies. Microscopic and electron transmission microscopic observations demonstrated disruption of the endothelial cell layer with preservation of the architecture in the remaining layers. This is consistent with previous works. The other two valves presented lipid degeneration of the spongiosa in one and diffuse fibrous degeneration in the other. This work demonstrates that valves submitted to prolonged storage periods do not undergo further alterations than those recently preserved. It also demonstrates that the pigs own pathology may cause significant structural modifications of the tissue which are only detected with rigorous examination using magnifying optical techniques.

Bioprosthesis↗