A spark counter as a control unit of a radio frequency surgery device.

A new approach in radio frequency (rf) electrosurgery, used for tissue treatment, is achieved by using a new process control method. An external control unit allows a commonly available rf-generator to automatically supply the appropriate power for differing tissue types, thus ensuring best cutting quality. The sparks, generated during the scalpel electrode interaction with the tissue, appear statistically distributed. The spark rate depends on various factors and is monotonic with the supplied electrical power. This allows it to be used as the controlled variable in the cutting process. The ac current passing through the tissue is evaluated by an external control unit using an analyzation algorithm to determine the number of sparks. The external unit is comprised of a system, which measures the spark rate, and a subsequent proportional integral (P.I.) controller. The functionality of the control method as well as the electrical circuitry is verified through cuts with different degrees of carbonization and cuts through tissue heterojunctions.

Adipose Tissue↗

Regulation of pacing rate by variations of mixed venous oxygen saturation.

Right ventricular oxygen saturation (SO2) may be an ideal sensor for determining the rate of an implanted pacemaker. In order to prove this hypothesis, the obtained signals were optimally analyzed; determinations of SO2 at rest and during exercise were made in healthy volunteers and in patients with pacemakers; and an algorithm was developed for varying pacing rate as a function of measured SO2. The results suggest that this method may be applicable to the long-term implantee.

Arrhythmias, Cardiac↗

An active optical sensor for monitoring mixed venous oxygen-saturation for an implantable rate-regulating pacing system.

Presently available physiologic pacing systems do not fully restore rate regulation, especially in respect to little or no atrial response to activity. Other biologic parameters, detected by sensors, may provide the physiologic responsiveness necessary to rate-regulating pacemakers. An optical sensor using mixed venous oxygen saturation may be the ideal parameter for such a pacing system. At present, further research is necessary to elaborate a suitable algorithm for optimal rate control.

Arrhythmias, Cardiac↗