PubMed Health⌕ Search

Biomedical subjects

H D Mulder

Publications and source records attributed to H D Mulder.

3 recordsLinked to original sources

Comparison of laser Doppler flowmetry and thermometry in the postoperative monitoring of replantations.

Reliable postoperative monitoring in microvascular surgery is necessary to improve the success rate of reexplorations following vascular compromise. Surface thermometry is known as an easy and inexpensive objective postoperative monitor and therefore is used by many microsurgeons. Reliability, however, is not satisfactory, and therefore several other instrumental methods have been tested of which laser Doppler flowmetry shows the most promising results. This study compared laser Doppler flowmetry to thermometry in the postoperative monitoring after replantation surgery. In 34 patients, 45 replantations and revascularizations were monitored by laser Doppler flowmetry and thermometry. A reliable alarm value of 10 PU was defined for replantations and revascularizations, with a sensitivity of 93% and a specificity of 94%. Thermometry showed a sensitivity of 84% and a specificity of 86% at 29 degrees C.

Adolescent↗

The predictive value of the laser Doppler flowmeter for postoperative microvascular monitoring.

Reliable postoperative monitoring in microvascular surgery is necessary to improve the low success rate of reexploration after vascular compromise. The use of laser Doppler flowmetry has been evaluated in this study. From November 1985 to January 1988, 79 microvascular operations were monitored postoperatively. These consisted of 45 replants and revascularizations in 34 patients, as well as 34 free vascularized tissue transfers. In the replant and revascularization group, a statistically significant difference in laser Doppler flowmetry readings has been demonstrated between well-vascularized and circulatory impaired patients (p < 0.001). In this study a reliable critical (alarm) value could be defined for replants and revascularizations with a sensitivity of 93% and a specificity of 94%. This critical alarm value can be adjusted according to the individual surgeon's attitude toward reexploration. Similar laser Doppler flowmetry characteristics were seen in patients with free vascularized tissue transfers; however, the numbers in this part of the study were too small to define reliable critical alarm values. The laser Doppler flowmeter is recommended for the postoperative evaluation of tissue after microvascular anastomoses, as it indicates vascular occlusion at an early stage where reexploration is worthwhile.

Adolescent↗

Differences between arterial and venous occlusion in microvascular surgery.

Between November 1985 and November 1988 11 patients developed arterial occlusion after microvascular anastomoses, 10 patients venous occlusions and five combined arterial and venous occlusions. We undertook a retrospective study to see whether colour, capillary refill, thermometry, or laser Doppler measurements could distinguish arterial and venous occlusions. Neither skin thermometry nor total backscattered light intensity change and flow band width (laser Doppler measurements) were significantly different (p > 0.05) between arterial and venous occlusions, but there were significant differences in colour (p = 0.006), capillary refill (p = 0.007), and laser Doppler flow (p = 0.02). The values obtained from cases with combined arterial and venous occlusions were like those of a venous occlusion or of an arterial occlusion or somewhere in between. Although none of the variables was diagnostic, we advise that the suspect vascular anastomosis should first be checked during reoperation. If an occluded anastomosis is found, one should also check the other anastomosis because occlusion of both artery and vein cannot be reliably detected.

Anastomosis, Surgical↗