Comparison of the cellular protein composition of aortic smooth muscle cells in vivo and in vitro by two-dimensional gel electrophoresis.

Vascular smooth muscle cells are of major interest for the evaluation of atherosclerotic processes. By the use of two-dimensional gel electrophoresis and subsequent silver staining we investigated the protein expression of smooth muscle cells in the native thoracic aorta, immediately after enzymatic disaggregation, in subconfluent proliferating and in postconfluent nonproliferating primary cell cultures. Compared to the native thoracic aorta the protein composition of smooth muscle cells in cell culture is changed dramatically. Furthermore, significant differences in protein expression between proliferating and nonproliferating smooth muscle cells in cell culture were found.

Animals↗

MR-guided placement of a temporary vena cava filter: technique and feasibility.

The purpose of this paper was to investigate the feasibility of MR-guided insertion of a temporary vena cava filter on an open low-field imager. In vivo procedures were performed on four anesthetized pigs using a common nonferromagnetic temporary vena cava filter and a special prototype guidewire developed for vascular interventions guided by low-field MRI. Breath-hold spoiled gradient-echo sequences (fast low-angle shot [FLASH]) with flow compensation were used for position monitoring of the passively visualized intravascular devices. Using the described technique and equipment, all steps of the procedure were feasible in the MR unit. Practicability of the procedure seems to be sufficient for clinical purposes but was inferior compared to the conventional technique of filter placement.

Animals↗

Visualization of magnetic resonance-compatible needles at 1.5 and 0.2 Tesla.

PURPOSE: For two types of passively visualizable magnetic resonance (MR)-compatible needles, the size of susceptibility artifacts was investigated at 0.2 and 1.5 Tesla (T) and assessed regarding their suitability for needle visualization. METHODS: Phantom trials were performed using T1-weighted spin echo (SE), turbospin echo (TSE) and gradient echo (GE) sequences and different angles beta between the needles and the main magnetic field (B0). RESULTS: Depending on the needle angle beta and the applied pulse sequence, we found artifact diameters of 0-9.7 mm employing SE, of 1.7-9.4 mm employing TSE, and of 1.4-20.6 mm employing GE at 1.5 T. At 0.2 T, we found artifact diameters of 0-5.7 mm employing SE, of 0-6.3 mm employing TSE, and of 0-11.3 mm employing GE. CONCLUSION: Comparing artifact sizes at 1. 5 T and 0.2 T, low field strength is superior for passive visualization of the needles tested-especially if GE imaging is performed.

Artifacts↗

Central venous access ports placed by interventional radiologists: experience with 125 consecutive patients.

PURPOSE: To assess safety and function of central venous port systems implanted percutaneously in the interventional radiology suite. METHODS: One hundred and twenty-five consecutive ports in 123 patients were evaluated retrospectively. One hundred and twenty ports were implanted via the subclavian vein. RESULTS: Technical success was 100%. Fourteen patients (11.2%) experienced immediate procedural complications, all minor (pneumothorax 1.6%). During follow-up (4-343 days, mean service period 97.8 days), nine complications occurred, six of which were major. These were three port infections which led to hospitalization and port removal, one chamber penetration through the skin, and two port occlusions. Port removal as a result of complications was performed in six patients. Altogether, 20 complications occurred within a total of 11,056 days of service, which means 1.8 events per 1000 days of service. CONCLUSION: Percutaneous implantation of central venous port systems is safe and easy to perform. Complication rates of this study compare favorably with those of other radiological and surgical series.

Administration, Cutaneous↗

Temporary vena cava filters and ultrahigh streptokinase thrombolysis therapy: a clinical study.

PURPOSE: To assess the efficacy of temporary vena cava filters in patients undergoing ultrahigh-dose streptokinase thrombolysis for iliocaval thrombosis and to determine therapy success and filter and therapy complications. METHODS: Forty-five patients were studied regarding extension and characteristics of thrombosis, duration, success, and complications of thrombolysis therapy, filter type, access route, pulmonary embolisms, and filter complications. RESULTS: Complete recanalization was achieved in 57% of cases. Filters were inserted predominantly via a transbrachial route. One fatal pulmonary embolism (2%) occurred 1 day after starting thrombolysis. No other pulmonary embolism was noted. Other complications were induced by thrombolysis alone (n = 12), thrombolysis and filter (n = 9), and filter alone (n = 11). CONCLUSION: Fatal pulmonary embolisms as a complication of ultrahigh-dose treatment of pelvic or caval thrombosis can not safely be prevented by the temporary vena cava filters currently available. Filter design needs to be improved.

Adolescent↗

In vitro studies of temporary vena cava filters.

PURPOSE: To evaluate the clot trapping capacity of different temporary vena cava filters in a vena cava model. METHODS: A vena cava flow model was built using PVC tubing, a hemodialysis membrane and a pulsatile pump. Blood was imitated by a Dextran 40 solution. Five different temporary vena cava filters and two prototypes were tested using human thrombi. The mechanism of clot capture was observed. RESULTS: Decreasing rank order according to decreasing percentage of clots captured for the 21-mm diameter vena cava model was Cook (C) > Angiocor (A) > Cordis (CD) > Antheor (TF-6) > DIL for thrombi with a diameter of 3 mm and A > C > CD > TF-6 > DIL for 5-mm thrombi. In a cava with diameter of 28 mm, decreasing rank order was C > CD = A > TF-6 > DIL and C > CD = A > DIL > TF-6 for 3- and 5-mm thrombi, respectively. Two new prototypes, the TF-8 and TF-10 filters, achieved better results than the TF-6 filter and were in most conditions comparable to the A and CD filters. In most cases, thrombi were trapped between filter and cava wall. CONCLUSION: The vena cava flow model demonstrates significant differences in rates of clot capture (range 22%-98%) depending on cava diameter, thrombus size, and filter type.

Equipment Design↗

Initial clinical experience with a new pulsed dye laser device in angioplasty of limb ischemia and shunt fistula obstructions.

Selective plaque ablation with laser radiation at 405-530 nm in vitro has been reported. We investigated the possibilities of a new pulsed dye laser device for in vivo recanalization of arteries in ischemic lower limbs and stenoses/occlusions of arterio-venous hemodialysis shunt fistulae. A specially designed 9F or 7F multifiber catheter was used for treatment of 10 patients with lower limb artery obliterations and 11 patients with malfunctioning hemodialysis access fistulae (HAF). The recanalization technical success was 5/5 in the iliac arteries (IA), 4/5 in the superficial femoral arteries (SFA), and 11/11 in the HAF. Early re-occlusions occurred in one SFA and one IA, respectively, caused by very bad run-off. There was one clinically insignificant SFA perforation. Additional balloon angioplasty was considered necessary in 10/16 lesions. Mean ankle-arm index increased from 0.68 to 0.97. With two exceptions all HAF patients were re-integrated in the dialysis program. Pulsed dye laser angioplasty promises to be an effective and fast method for plaque ablation/debulking. The first clinical experience confirms previous in vitro results. In particular laser recanalization may become the method of choice for treatment of rigid HAF obstructions and it seems to be superior to vascular surgery or balloon angioplasty alone.

Aged↗

Follow-up study of renal transplants by duplex Doppler and gray-scale ultrasound.

In the early postoperative period after renal transplantation 388 follow-up ultrasound examinations were performed in 77 patients. Over a period of 18 months standardized duplex indices (resistive index, pulsatility index) and gray-scale parameters (parenchyma/sinus index; medulla/cortex index) were sampled. These data were correlated retrospectively with clinical and pathological diagnoses. To delineate the individual course of duplex and gray-scale indices during different transplant diseases we created a new parameter: the MID (maximal index difference) which is a result of the difference between the highest index during the phase of renal dysfunction and the lowest index during the phase of normal renal function. This MID, calculated for duplex indices and for the parenchyma/sinus index, indicated significant differences in the behavior of renal transplants during the four main diseases: interstitial rejection, vascular rejection, acute tubular necrosis and Cyclosporine A nephrotoxicity. Using the MIDs, a table of cut-off values was established, which enables to differentiate retrospectively these four transplant complications with a sensitivity of 84% and specificity of 81%. In our opinion consequent follow-up examinations with duplex and gray-scale sonography should be performed, enabling sonography to become a helpful diagnostic instrument in the monitoring of renal transplants.

Cyclosporine↗

Clinical experience with temporary vena caval filters.

PURPOSE: To look at the benefits and complications of different vena caval filters inserted prophylactically. Three temporarily implantable caval filter systems were used in 67 patients. MATERIALS AND METHODS: Twelve Cook filters (six transjugular, six transfemoral), 11 Angiocor filters (one transjugular, 10 transbrachial), and 44 Antheor filters (three transjugular, four transfemoral, 37 transbrachial) were successfully implanted. In known iliac vein or caval thrombosis, the prophylactic filters were placed during thrombolytic therapy in 46 cases, surgery in 17 cases, thrombosis in pregnancy in three cases, and high-dose heparinization without lysis in one case. RESULTS: One patient had a fatal pulmonary embolism during treatment; seven thrombi were detected in the filter. Other complications were caused either by the underlying therapy alone (one fatal outcome of abdominal aorta aneurysmal surgery, two cases of cerebral hemorrhage, two cases of retroperitoneal hematomas, two cases of streptokinase fever reactions, one compartment syndrome, two cases of macrohematuria), by the combination of therapy and caval filter implantation (three cases of groin hematomas, three cases of arm hematomas), or by filter implantation alone (two cases of subclavian vein thrombosis, one catheter infection, one dislocation, one air embolism, one basket rupture). The bleeding complications were related to the aggressive thrombolytic therapy and would have occurred without filter implantation. CONCLUSION: Because temporary caval filters have no long-term complications per se, their use seems sensible as long as there are stringent indications, including the presence of iliac vein or caval thrombosis and risk of thrombus mobilization. The Antheor filter system was the most convenient system for implantation.

Adolescent↗

Evaluation of brainstem stroke using brainstem auditory evoked responses.

Brainstem stroke syndromes are primarily determined by clinical criteria. There are few diagnostic procedures which are of benefit for the evaluation of brainstem ischemic events. Brainstem auditory evoked responses (BAERs) are a new electrophysiologic technique for assessing brainstem function. To evaluate the use of BAERs in patients with brainstem ischemic events, 35 individuals with recent brainstem strokes, selected by strict clinical criteria, were evaluated with BAERs. The initial BAER was abnormal in 22 of 35 patients (63%). When the clinical course and site of the lesion are correlated with the BAER results, several trends emerge. An unstable course, characterized by progression or remission and relapse, was present in 19/35 (54%) of patients, and 15/19 (79%) of these individuals had an initially abnormal BAER. The other 16 brainstem stroke patients with a stable clinical course had an initially abnormal BAER in 7 instances (44%). This difference is statistically significant at the p = 0.04 level. The principal sites of ischemia were mesencephalic in 11/35, pontine in 13/35, and medullary in 11/35. The association of an abnormal BAER with an unstable clinical course seemed independent of the site of the lesion, However, of the 9 deaths that occurred, all were in patients with mesencephalic or pontine lesions, and 8 of these individuals had an initially abnormal BAER. Abnormal BAERs in patients with brainstem ischemic lesions correlate with an unstable clinical course. Furthermore, individuals with pontomesencephalic infarction and abnormal BAERs have an especially poor prognosis. The BAER may be of prognostic value in the early evaluation of patients with brainstem ischemic strokes.

Brain Ischemia↗