PubMed Health⌕ Search

Biomedical subjects

H Delingette

Publications and source records attributed to H Delingette.

11 recordsLinked to original sources

An electromechanical model of the heart for image analysis and simulation.

This paper presents a new three-dimensional electromechanical model of the two cardiac ventricles designed both for the simulation of their electrical and mechanical activity, and for the segmentation of time series of medical images. First, we present the volumetric biomechanical models built. Then the transmembrane potential propagation is simulated, based on FitzHugh-Nagumo reaction-diffusion equations. The myocardium contraction is modeled through a constitutive law including an electromechanical coupling. Simulation of a cardiac cycle, with boundary conditions representing blood pressure and volume constraints, leads to the correct estimation of global and local parameters of the cardiac function. This model enables the introduction of pathologies and the simulation of electrophysiology interventions. Moreover, it can be used for cardiac image analysis. A new proactive deformable model of the heart is introduced to segment the two ventricles in time series of cardiac images. Preliminary results indicate that this proactive model, which integrates a priori knowledge on the cardiac anatomy and on its dynamical behavior, can improve the accuracy and robustness of the extraction of functional parameters from cardiac images even in the presence of noisy or sparse data. Such a model also allows the simulation of cardiovascular pathologies in order to test therapy strategies and to plan interventions.

Body Surface Potential Mapping↗

A topologically faithful, tissue-guided, spatially varying meshing strategy for the computation of patient-specific head models for endoscopic pituitary surgery simulation.

This paper presents a method for tessellating tissue boundaries and their interiors, given as input a tissue map consisting of relevant classes of the head, in order to produce anatomical models for finite element-based simulation of endoscopic pituitary surgery. Our surface meshing method is based on the simplex model, which is initialized by duality from the topologically accurate results of the Marching Cubes algorithm, and which features explicit control over mesh scale, while using tissue information to adhere to relevant boundaries. Our mesh scale strategy is spatially varying, based on the distance to a central point or linearized surgical path. The tetrahedralization stage also features a spatially varying mesh scale, consistent with that of the surface mesh.

Algorithms↗

Simulation of cardiac pathologies using an electromechanical biventricular model and XMR interventional imaging.

Simulating cardiac electromechanical activity is of great interest for a better understanding of pathologies and for therapy planning. Design and validation of such models is difficult due to the lack of clinical data. XMR systems are a new type of interventional facility in which patients can be rapidly transferred between X-ray and MR systems. Our goal is to design and validate an electromechanical model of the myocardium using XMR imaging. The proposed model is computationally fast and uses clinically observable parameters. We present the integration of anatomy, electrophysiology, and motion from patient data. Pathologies are introduced in the model and simulations are compared to measured data. Initial qualitative comparison on the two clinical cases presented is encouraging. Once fully validated, these models will make it possible to simulate different interventional strategies.

Algorithms↗

Removing tetrahedra from manifold tetrahedralisation: application to real-time surgical simulation.

This paper proposes an efficient method for removing tetrahedra from a tetrahedral mesh while keeping its manifold property. We first define precisely the notion of manifold tetrahedral mesh and stress its relevance in the context of real-time surgery simulation. We then provide a method for removing a tetrahedron that complies with the manifold definition. This removal may require in some cases the removal of neighboring tetrahedra. After providing an exhaustive description of the tetrahedron removal algorithm, its efficiency is evaluated for different mesh configurations. This algorithm is currently used in the context of real-time surgery simulation where the action of an ultrasonic lancet can be simulated by the removal of small set of tetrahedra from a tetrahedralisation.

Algorithms↗

Deformable biomechanical models: application to 4D cardiac image analysis.

This article describes a methodology for creating a generic volumetric biomechanical model from different image modalities and segmenting time series of medical images using this model. The construction of such a generic model consists of three stages: geometric meshing, non-rigid deformation of the mesh in images of various modalities, and image-to-mesh information mapping through rasterization. The non-rigid deformation stage, which relies on a combination of global and local deformations, can then be used to segment time series of images, e.g. cine MRI or gated SPECT cardiac images. We believe that this type of deformable biomechanical model can play an important role in the extraction of useful quantitative local parameters of cardiac function. The biomechanical model of the heart will be coupled with an electrical model of another collaborative project in order to simulate and analyze a larger class of pathologies.

Algorithms↗

Fully automatic anatomical, pathological, and functional segmentation from CT scans for hepatic surgery.

OBJECTIVE: To improve the planning of hepatic surgery, we have developed a fully automatic anatomical, pathological, and functional segmentation of the liver derived from a spiral CT scan. MATERIALS AND METHODS: From a 2 mm-thick enhanced spiral CT scan, the first stage automatically delineates skin, bones, lungs, kidneys, and spleen by combining the use of thresholding, mathematical morphology, and distance maps. Next, a reference 3D model is immersed in the image and automatically deformed to the liver contours. Then an automatic Gaussian fitting on the imaging histogram estimates the intensities of parenchyma, vessels, and lesions. This first result is next improved through an original topological and geometrical analysis, providing an automatic delineation of lesions and veins. Finally, a topological and geometrical analysis based on medical knowledge provides hepatic functional information that is invisible in medical imaging: portal vein labeling and hepatic anatomical segmentation according to the Couinaud classification. RESULTS: Clinical validation performed on more than 30 patients shows that delineation of anatomical structures by this method is often more sensitive and more specific than manual delineation by a radiologist. CONCLUSION: This study describes the methodology used to create the automatic segmentation of the liver with delineation of important anatomical, pathological, and functional structures from a routine CT scan. Using the methods proposed in this study, we have confirmed the accuracy and utility of the creation of a 3D liver model compared with the conventional reading of the CT scan by a radiologist. This work may allow improved preoperative planning of hepatic surgery by more precisely delineating liver pathology and its relationship to normal hepatic structures. In the future, this data may be integrated with computer-assisted surgery and thus represents a first step towards the development of an augmented-reality surgical system.

Humans↗

An automatic virtual patient reconstruction from CT-scans for hepatic surgical planning.

UNLABELLED: PROBLEM/BACKGROUND: In order to help hepatic surgical planning we perfected automatic 3D reconstruction of patients from conventional CT-scan, and interactive visualization and virtual resection tools. TOOLS AND METHODS: From a conventional abdominal CT-scan, we have developed several methods allowing the automatic 3D reconstruction of skin, bones, kidneys, lung, liver, hepatic lesions, and vessels. These methods are based on deformable modeling or thresholding algorithms followed by the application of mathematical morphological operators. From these anatomical and pathological models, we have developed a new framework for translating anatomical knowledge into geometrical and topological constraints. More precisely, our approach allows to automatically delineate the hepatic and portal veins but also to label the portal vein and finally to build an anatomical segmentation of the liver based on Couinaud definition which is currently used by surgeons all over the world. Finally, we have developed a user friendly interface for the 3D visualization of anatomical and pathological structures, the accurate evaluation of volumes and distances and for the virtual hepatic resection along a user-defined cutting plane. RESULTS: A validation study on a 30 patients database gives 2 mm of precision for liver delineation and less than 1 mm for all other anatomical and pathological structures delineation. An in vivo validation performed during surgery also showed that anatomical segmentation is more precise than the delineation performed by a surgeon based on external landmarks. This surgery planning system has been routinely used by our medical partner, and this has resulted in an improvement of the planning and performance of hepatic surgery procedures. CONCLUSION: We have developed new tools for hepatic surgical planning allowing a better surgery through an automatic delineation and visualization of anatomical and pathological structures. These tools represent a first step towards the development of an augmented reality system combined with computer assisted tele-robotical surgery.

Computer Graphics↗

Efficient linear elastic models of soft tissues for real-time surgery simulation.

In this paper, we describe the basic components of a surgery simulator prototype developed at INRIA. We present two physical models which are well suited for surgery simulation. These models are based on linear elasticity theory and finite elements modeling. The former model can deforme large tetrahedral meshes in real-time but does not allow any topological changes. On the contrary, the latter biomechanical model can simulate the cutting and tearing of soft tissue but must have a limited number of vertices to run in real-time. We propose a method for combining these two approaches into a hybrid model which may allow real time deformations and cuttings of large enough anatomical structures.

Biomechanical Phenomena↗

Virtual reality applied to hepatic surgery simulation: the next revolution.

OBJECTIVE: This article describes a preliminary work on virtual reality applied to liver surgery and discusses the repercussions of assisted surgical strategy and surgical simulation on tomorrow's surgery. SUMMARY BACKGROUND DATA: Liver surgery is considered difficult because of the complexity and variability of the organ. Common generic tools for presurgical medical image visualization do not fulfill the requirements for the liver, restricting comprehension of a patient's specific liver anatomy. METHODS: Using data from the National Library of Medicine, a realistic three-dimensional image was created, including the envelope and the four internal arborescences. A computer interface was developed to manipulate the organ and to define surgical resection planes according to internal anatomy. The first step of surgical simulation was implemented, providing the organ with real-time deformation computation. RESULTS: The three-dimensional anatomy of the liver could be clearly visualized. The virtual organ could be manipulated and a resection defined depending on the anatomic relations between the arborescences, the tumor, and the external envelope. The resulting parts could also be visualized and manipulated. The simulation allowed the deformation of a liver model in real time by means of a realistic laparoscopic tool. CONCLUSIONS: Three-dimensional visualization of the organ in relation to the pathology is of great help to appreciate the complex anatomy of the liver. Using virtual reality concepts (navigation, interaction, and immersion), surgical planning, training, and teaching for this complex surgical procedure may be possible. The ability to practice a given gesture repeatedly will revolutionize surgical training, and the combination of surgical planning and simulation will improve the efficiency of intervention, leading to optimal care delivery.

Computer Simulation↗

A fully three-dimensional method for facial reconstruction based on deformable models.

Two facial models corresponding to two deceased subjects have been manually created and the two corresponding skulls have been dissected and skeletonized. These pairs of skull/ facial data have been scanned with a CT scanner, and the computed geometric three-dimensional models of both skulls and facial tissue have been built. One set of skull/facial data will be used as a reference set whereas the second set is used as ground truth for validating our method. After a semi-automatic face-skull registration, we apply an original computing global parametric transformation T that turns the reference skull into the skull to be reconstructed. This algorithm is based upon salient lines of the skull called crest lines: more precisely the crest lines of the first skull are matched to the crest lines of the second skull by an iterative closest point algorithm. Then we apply this algorithm to the reference face to obtain the "unknown" face to be reconstructed. The reliability and difficulties of this original technique are then discussed.

Cephalometry↗

Geometric and physical representations for a simulator of hepatic surgery.

Despite the large interest in simulators of minimally invasive surgery, it is still unclear to what extent simulators can achieve the task of training medical students in surgical procedures. The answer to that question is certainly linked to the realism of displays and force-feedback systems and to the level of interaction provided by the computer system. In this paper, we describe the virtual environment for anatomical and surgical training on the liver, currently under construction at INRIA. We specifically address the problems of geometric representation and physical modeling and their impact on the two aforementioned problems: realism and real-time interaction.

Computer Simulation↗